EM TEST CWS 500N2.2 Continuous Wave Simulator

Description

CWS 500N2.2 Simulator for BCI (Bulk Current Injection) from 9 kHz up to 1 GHz

EM TEST CWS 500N2.2 Continuous Wave Simulator is designed for testing RF conducted immunity to narrowband radiated electromagnetic energy.

The CWS 500N2.2 is the first compact solution world-wide for testing rf conducted immunity to narrowband radiated electromagnetic energy. The unit includes a controller, signal generator, amplifier, directional coupler and RF power measurement of up to three signals in parallel. A built-in RF switch allows to connect and use any external amplifier to extend the system’s capabilities.

The CWS 500N2.2 is used for tests as per MIL STD 461 D/E/F/G CS 114, ISO 11452-4 and IEC/EN 61000-4-6 with CDNs and EM clamps and related standards.

 

MODEL OVERVIEW

CWS 500N2.3 Continuous Wave Simulator for BCI (Bulk current injection) from 4 kHz up to 1 GHz

Features

  • Supports BCI testing as per various standard requirements
  • Basic frequency range 9 kHz up to 400 MHz
  • Extendable frequency range up to 1 GHz
  • Built-in 110 W class A amplifier up to 400 MHz
  • Built-in RF switch to connect external amplifier
  • Built-in directional coupler
  • Built-in 3-channel power meter up to 1 GHz
Download Data Sheet
Print
Email

Specifications

TECHNICAL DETAILS
OUTPUT
RF output N connector at the front panel
Output power Built-in amplifier 110 W (nominal)
Gain amplifier > 50 dB
Output impedance 50 ohm
Harmonic distortion < -20 dBc at max. power
Insertion loss Approx. 1 dB (directional coupler + RF relay)
SIGNAL GENERATOR
Output level -63.5 dBm to 0 dBm
Frequency range 9 kHz to 1 GHz
Output impedance 50 ohm
Direct RF output To control an external amplifier
TEST FREQUENCIES
Frequency range 9 kHz – 400 MHz (built-in amplifier) 9 kHz – 1,000 MHz (ext. amplifier)
Unmodulated signal CW (continuous wave)
Amplitude modulation Frequency: 1 Hz to 3,000 Hz, Index: 1% to 95%,
Pulse modulation Frequency: 1 Hz to 3,000 Hz Index: 10% to 80%
DUAL DIRECTIONAL COUPLER
Dual directional coupler Included to measure forward power and reverse power
Frequency range 10 kHz to 1 GHz
Power 200 W max.
Insertion loss 0.6 dB max.
Mainline VSWR 1.1:1 max.
MEASUREMENT
PM 1000 3-channel power meter up to 1 GHz
Forward power Internal power meter #1, -10 dBm to +52 dBm
Reverse power Internal power meter #2, -10 dBm to +52 dBm
Injected current (Monitor) Internal power meter #3, -45 dBm to +13 dBm
TIME PARAMETERS
Dwell time td = 0.3 s – 9,999 s
Pause time tr = 0/0.3 s – 9,999 s
INTERFACE
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
Fail 1 BNC input; test will be stopped (active low)
Fail 2 BNC input; test status will be saved (max. 10 events) when active low. Test continues
GENERAL DATA
Dimensions, weight 19″/6 HU, 31.6 kg
Supply voltage 115 V or 230 V +10/-15 %, 50/60 Hz
Input power Max. 1430 W Inrush
Power factor cos(phi) = 0.96 at max. output power as per IEC 555
Fuses 2×6.3 AT (115 V) or 2×6.3 AT (230 V)