Tektronix DPO4032 2 Channel 350 MHz Digital Oscilloscope 2.5 GSa/s

Description

The DPO4000 oscilloscope family ranges from 350 MHz to 1 GHz and is the first to offer the groundbreaking Wave Inspector™, an unprecedented set of easy-to-use tools for discovery and efficient viewing, navigating, and analyzing waveform data. With Wave Inspector™, serial triggering, protocol decode, USB plug-and-play PC connectivity, a 10.4″ XGA display, and smallest footprint in its class, the new portable DPO4000 simplifies debug and sets new standards for productivity, performance, value, and ease-of-use that will transform the market. The DPO4000 will meet the pressing debug needs of embedded systems design engineers.

 

Features

  • 350 MHz Bandwidth Model
  • 2 Channel Model
  • 2.5 GS/s on All Channels
  • 10 Megasample Record Length on All Channels
  • 50,000 wfms/s Maximum Waveform Capture Rate
  • Wave Inspector® Controls Provide Unprecedented Efficiency in Waveform Analysis
  • I2C, SPI, CAN, LIN, FlexRay and RS-232/422/485/UART Serial Triggering and Analysis Options
  • 10.4 in. (264 mm) XGA Color Display
  • Small Footprint and Lightweight – only 5.4 in. (137 mm) deep and 11 lbs. (5 kg)!
  • USB and CompactFlash on Front Panel for Quick and Easy Storage
  • Built-in Ethernet Port
  • Plug ‘n’ Play Connectivity and Analysis Software Solutions
  • USB 2.0 Device Port for Direct PC Control of Oscilloscope using USBTMC
  • Suite of Advanced Triggers
  • e*Scope® Remote Viewing and Control
  • Interoperability with Tektronix Logic Analyzers
  • TekVPI™ Probe Interface Supports Active, Differential and Current Probes for Automatic Scaling and Units
  • HDTV and Custom Video Trigger Option

Tektronix DPO4032 Applications

  • Embedded Design and Debug
  • Investigation of Transient Phenomena
  • Power Measurements
  • Video Design and Debug
  • Spectral Analysis
  • Automotive Electronics Design and Debug
  • Manufacturing Test and Quality Control
  • Electro-mechanical Design and Analysis
  • Bio-medical Product Development
  • Industrial Control
Download Data Sheet
Print
Email

Specifications

Characteristics

Vertical System

   

DPO4032

Input Channels

2

Analog Bandwidth (-3 dB)

   5 mV/div – 1 V/div

350 MHz

Calculated Rise Time

   5 mV/div (typical)

1 ns

Hardware Bandwidth Limits

20 MHz or 250 MHz

Input Coupling

AC, DC, GND

Input Impedance

1 MΩ ±1%, 50 Ω ±1%

Input Sensitivity, 1 MΩ

1 mV/div to 10 V/div

Input Sensitivity, 50 Ω

1 mV/div to 1 V/div

Vertical Resolution

8 bits (11 bits with Hi Res)

Max Input Voltage, 1 MΩ

250 VRMS with peaks ≤±400 V

Max Input Voltage, 50 Ω

5 VRMS with peaks ≤±20 V

DC Gain Accuracy

±1.5% with offset set to 0 V

Offset Range

1 MΩ 

50 Ω

   1 mV/div to 50 mV/div

±1 V

±1 V

   50.5 mV/div to 99.5 mV/div

±0.5 V

±0.5 V

   100 mV/div to 500 mV/div

±10 V

±10 V

   505 mV/div to 995 mV/div

±5 V

±5 V

   1 V/div to 5 V/div

±100 V

±5 V

   5.05 V/div to 10 V/div

±50 V

NA

Channel-to-channel Isolation

≥100:1 at ≤100 MHz and ≥30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings

  Horizontal System

   

DPO4032

Maximum Sample Rate (all channels)

2.5 GS/s

Maximum Record Length (all channels)

10 M points

Maximum Duration at Highest Sample Rate (all channels)

4 ms

Timebase Range (s/div)

1 ns to 400 s

Timebase Delay Time Range

–10 divisions to 50 s

Channel-to-channel Deskew Range

±100 ns

Timebase Accuracy

±5 ppm over any ≥1 ms interval

  TRIGGER SYSTEM

Main Trigger Modes

Auto, Normal, and Single

Trigger Coupling

DC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity)

Trigger Holdoff Range

20 ns to 8 s

Sensitivity

   

   Internal DC Coupled

0.4 div DC to 50 MHz increasing to 1 div at rated bandwidth

   External (auxiliary input)

200 mV from DC to 50 MHz increasing to 500 mV at 250 MHz

Trigger Level Range

   

   Any Channel

±8 divisions from center of screen

   External (auxiliary input)

±8 V

 ACQUISITION MODES

Sample

Acquire sampled values

Peak Detect

Captures glitches as narrow as 200 ps at all sweep speeds

Averaging

From 2 to 512 waveforms included in average

Envelope

Min- max envelope reflecting Peak Detect data over multiple acquisitions

Hi Res

Real-time boxcar averaging reduces random noise and increases resolution

Roll

Scrolls waveforms right to left across screen at sweep speeds slower than or equal to 40 ms/div

 TRIGGER MODES

Edge

Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, HF reject, LF reject, and noise reject.

Pulse Width

Trigger on width of positive or negative pulse that are >, <, = or ≠ a specified period of time

Runt

Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again

Logic

Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as High, Low or Don't Care.

Setup & Hold

Trigger on violations of both setup time and hold time between clock and data present on any two input channels

Rise/Fall Time

Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative or either.

Video

Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals.

Extended Video (Optional)

Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50, 1080p/60, and custom bi-level and tri-level sync video standards.

I2C (Optional)

Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address & Data on I2C buses up to 3.4 Mb/s

SPI (Optional)

Trigger on SS, Idle Time, MOSI, MISO, or MOSI & MISO on SPI buses up to 10.0 Mb/s

CAN (Optional)

Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier & Data, End of Frame, or Missing ACK, or Bit Stuffing Errors on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =, >, ≥ or ≠ a specific data value. User adjustable sample point is set to 50% by default.

RS-232/422/485/UART (Optional)

Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, and Rx Data

LIN (Optional)

Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, or Errors such as Sync, Parity, or Checksum Errors

FlexRay (Optional)

Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field, Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors.

Trigger Delay by Time

4 ns to 8 s

Trigger Delay by Events

1 to 9,999,999 events

 WAVEFORM MEASUREMENTS

Cursors

Waveform and Screen

Automatic Measurements

29, of which up to eight can be displayed on screen at any one time. Measurements include Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area, and Cycle Area.

Measurement Statistics

Mean, Min, Max, Standard Deviation

Reference Levels

User definable reference levels for automatic measurements can be specified in either percent or units

Gating

Isolate the specific occurrence within an acquisition to take measurements, on using either the screen or waveform cursors

WAVEFORM MATH

Arithmetic

Add, subtract, multiply, and divide waveforms

Math Functions

Integrate, Differentiate, FFT

FFT

Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman-Harris.

Advanced Math

Define extensive algebraic expressions including waveforms, math functions, scalars, up to two user adjustable variables, and results of parametric measurements e.g. (Intg(Ch1-Mean(Ch1)) × 1.414 × VAR1)

SOFTWARE

NI LabVIEW SignalExpress™ Tektronix Edition LE

A fully interactive measurement software environment optimized for the DPO4000 Series, enables you to instantly acquire, generate, analyze, compare, import and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard DPO4000 Series support for acquiring, controlling, viewing, and exporting your live signal. The full version (SIGEXPTE) adds additional signal processing, advanced analysis, mixed signal, sweeping, limit testing and user-defined step capabilities and is available for a 30-day trial period standard with each instrument.

OpenChoice® Desktop

Enables fast and easy communication between a Windows PC and the DPO4000 Series, via USB or LAN. Transfer and save settings, waveforms, measurements, and screen images.

IVI Driver

Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET, and MATLAB

DISPLAY CHARACTERISTICS

Display Type

10.4 in. (264 mm) liquid crystal TFT color display

Display Resolution

1,024 horizontal×768 vertical pixels (XGA)

Waveform Styles

Vectors, Dots, Variable Persistence, Infinite Persistence

Graticules

Full, Grid, Cross Hair, Frame, IRE, and mV

Format

YT and simultaneous XY/YT

Waveform Capture Rate

Up to 50,000 wfms/sec

INPUT/OUTPUT PORTS

CompactFlash Drive

Front panel access (Type 1)

USB 2.0 Full Speed Host Port

Supports USB mass storage devices and printers. Two ports available on rear-panel and one on front-panel

USB 2.0 High Speed Device Port

Rear panel connector allows for control of oscilloscope via USBTMC or GPIB with a TEK-USB-488

LAN Port

RJ-45 connector, supports 10/100Base-T

XGA Video Port

DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector

Auxiliary Input

Front panel BNC connector. Input Impedance 1 MΩ. Max input 250 VRMS with peaks ≤±400 V

Probe Compensator Output

Front panel pins. Amplitude 2.5 V. Frequency 1 kHz

Trigger Out

Rear-panel BNC connector, provides a positive polarity pulse when the oscilloscope triggers

Kensington Lock

Rear-panel security slot connects to standard Kensington lock

POWER SOURCE

Power Source Voltage

100 to 240 V ±10%

Power Source Frequency

47 – 66 Hz (90 to 264 V),

360 – 440 Hz (100 to 132 V)

Power Consumption

250 W maximum

GENERAL CHARACTERISTICS

Physical Characteristics

Dimensions

mm

in.

   Height

229

9.0

   Width

439

17.3

   Depth

137

5.4

Weight

kg

lbs.

   Net

5

11

   Shipping

10

22

Rackmount Configuration

5U

Cooling Clearance

2 in. (51 mm) required on left side and rear of instrument

ENVIRONMENTAL

Temperature

Operating

0 °C to +50 °C

Non-Operating

–20 °C to +60 °C

Humidity

Operating

High: 40ºC to 50ºC, 10% to 60% Relative Humidity

Low: 0ºC to 40ºC, 10% to 90% Relative Humidity

Non-Operating

High: 40ºC to 60ºC, 5% to 60% Relative Humidity

Low: 0ºC to 40ºC, 5% to 90% Relative Humidity

Altitude

Operating

3,000 meters (9,843 feet)

Non-Operating

12,000 meters (39,370 feet)

Random Vibration

Operating

0.31 GRMS from 5 to 500 Hz, 10 minutes each axis, 3 axes, 30 minutes total

Non-Operating

2.46 GRMS from 5 to 500 Hz, 10 minutes each axis, 3 axes, 30 minutes total

Regulatory

Electromagnetic Compatibility

89/336/EEC

Safety

UL61010-1, Second Edition; CSA61010-1 Second Edition, EN61010-1: 2001; IEC 61010-1: 2001

  APPLICATION MODULES

DPO4EMBD

Embedded Serial Triggering and Analysis Module. Enables triggering on packet level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with timestamp information.

DPO4COMP

Computer Serial Triggering and Analysis Module. Enables triggering on packet level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools and packet decode tables with timestamp information.

DPO4AUTO

Automotive Serial Triggering and Analysis Module. Enables triggering on packet level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with timestamp information.

DPO4AUTOMAX

Extended Automotive Serial Triggering and Analysis Module. Enables triggering on packet level information on CAN, LIN and FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with timestamp information.

DPO4VID

HDTV and Custom (non-standard) Video Triggering Module

Categories
Stay informed

To keep you in the loop of our latest news, register now for our email newsletter.