Description
With 4 isolated channels and up to 7 hours of battery life, the lightweight THS3000 Handheld Oscilloscope Series enables you to safely make floating or differential measurements on your bench or in the field. Now you can tackle tough environments with the performance you expect from Tektronix safely and affordably.
With up to 200 MHz bandwidth, 4 channels, and 5 GS/s maximum sample rate, no other oscilloscope offers as much bandwidth and sample rate in a portable handheld form factor. The THS3000 Handheld Oscilloscope Series has 10,000 points record length per channel, enabling you to capture more signal information at higher sample rates to clearly see signal details. For applications where it is important to measure slow-changing signals over long time periods, the THS3000 Series offers Roll mode that extends the record length to 30,000 points of signal information.
Features
- 100 MHz or 200 MHz Bandwidth Models
- Maximum Sample Rates up to 5 GS/s and 200 ps Resolution
- 4 Fully Isolated and Floating Channels
- 600 VRMS CAT III, 1000 VRMS CAT II Rated Inputs (BNC to Earth Ground)
- 21 Automatic Measurements
- Waveform Math and FFT Spectral Analysis
- Volts, Time, Frequency, Watts Cursor Measurements
- 6 in. (153 mm) Bright Color Display
- USB Device and Host Support
- 7 Hours of Continuous Battery Operation
Tektronix THS3014 Applications
- Embedded Analog and Digital Design
- Power Devices, Power Electronics, and Power Supply Design
- Automotive and Avionics Design and Maintenance
- Industrial Equipment Design and Installation
- Field Test and Service
Specifications
Vertical System Analog Channels
Characteristic |
THS3014 |
THS3024 |
Isolated Input Channels |
4 |
4 |
Analog Bandwidth (–3 dB) |
100 MHz |
200 MHz |
Rise Time |
3.5 ns |
1.7 ns |
Hardware Bandwidth Limits |
20 kHz, 20 MHz, or full |
|
Input Coupling |
AC, DC |
|
Input Impedance |
1 MΩ ±1%, 14 pF ±2 pF |
|
Input Sensitivity Range |
2 mV/div to 100 V/div |
|
Vertical Resolution |
8 bits |
|
DC Gain Accuracy |
±2.1% of reading +0.04 × range/div for 5 mV/div to 100 V/div |
|
Max BNC Input Voltage |
(1 MΩ) 300 VRMS CAT III from BNC signal to BNC shell |
|
Max Probe Voltage (with standard THP0301-X probe) |
300 VRMS CAT III from 10:1 probe tip signal to BNC and reference lead |
|
Float Voltage |
1000 VRMS CAT II / 600 VRMS CAT III from BNC shell to earth ground |
|
Trace Positioning |
±4 divisions |
Horizontal System
Characteristic |
THS3014 |
THS3024 |
|
Maximum Sample Rate |
2.5 GS/s (1.25 GS/s 4-ch) |
5 GS/s (1.25 GS/s 4-ch) |
|
Maximum Record Length (All channels) |
10,000 points (30,000 points in Roll mode (4 ms to 2 min / div)) |
||
Time-base Range (s/div) |
2 ns to 4 s |
1 ns to 4 s |
|
Delay Time Range |
1 full screen (12 divisions) of pre-trigger or up to 100 screens (1,200 divisions) of post-trigger |
||
Timing Accuracy |
±100 ppm + 0.04 div |
||
Zoom |
Horizontally expand or compress a live or stopped waveform |
||
Trigger System
Characteristic |
Description |
Input Source |
Channel 1, 2, 3, or 4. All input references isolated from each other and earth ground |
Main Trigger Modes |
Auto-level, Auto, Normal, and Single |
Trigger Coupling |
DC, HF Reject, Noise Reject (reduces sensitivity) |
Trigger Sensitivity
Characteristic |
Description |
Internal DC Coupled |
0.5 divisions from DC to 5 MHz at >5 mV/div 1 divisions >5 MHz to 200 MHz (THS3024) 1 divisions >5 MHz to 100 MHz (THS3014) |
Trigger Level Range
Characteristic |
Description |
Any Channel |
±4.0 divisions |
Trigger Modes
Mode |
Description |
Edge |
Positive, negative, or dual slope on any input channel. Coupling includes DC, HF Reject, and Noise Reject |
Pulse Width |
Trigger on Channel 1, width of positive or negative pulses (glitches) that are >, <, =, or ≠ a specified period of time (resolution of 0.01 div with minimum time of 50 ns) |
Event |
Trigger on N-th occurrence of trigger (N selectable from 2 to 99) |
Video |
Trigger on Channel 1, line number, all lines, odd, even, or all fields on NTSC, PAL, PAL Plus, and SECAM signals |
Non-interlaced |
Trigger on Channel 1, high-res non-interlaced video with line frequencies from 14 kHz to 65 kHz |
Acquisition Modes
Mode |
Description |
Sample (Default) |
Acquire sampled values |
Glitch Detect |
Captures high frequency or glitches as narrow as 8 ns from 5 μs to 120 s / div |
Averaging |
Selectable from 2, 4, 8, or 64 waveforms |
Roll |
Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 4 ms/div |
Data Recorder |
Automatic data logging of 100 triggered records (screens) with date and time stamp. Store internally or to a USB device |
Waveform Compare |
Visually compare against user-definable reference waveforms or perform automatic Pass or Fail testing of 1 to 4 channels with data logging of test results |
Automatic Setup
Mode |
Description |
Autoset |
Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems |
Autorange |
Continuous auto-setup of vertical, horizontal, and trigger systems that track signal changes |
Waveform Measurements
Characteristic |
Description |
Cursors |
Time, Freq (1/T), Volts, Watts, Rise/Fall Time from any input channel or math waveform |
Automatic Measurements |
21. Up to 4 can be displayed on-screen at any one time. Measurements include: V DC, V ACRMS, V AC+DC, VPeak Max, VPeak Min, Peak to Peak, A DC, A AC, A AC+DC, Frequency, Rise Time (using cursors), Fall Time (using cursors), Phase (between any 2 inputs), Positive Pulse Width, Negative Pulse Width, Positive Duty Cycle, Negative Duty Cycle, dBV, dBm into 50 Ω and 600 Ω |
TrendPlot™ |
Records and graphically displays any 4 automatic scope measurements. Store internally or to USB flash drive for recall and analysis |
Waveform Math
Characteristic |
Description |
Arithmetic |
Add, subtract, and multiply waveforms |
FFT |
Spectral magnitude. Set FFT Vertical Scale to Linear or Logarithmic, and FFT Window to Automatic, Hamming, Hanning, or None |
Display Characteristics
Characteristic |
Description |
Display Type |
6 in. (153 mm) Liquid-crystal Color Display |
Display Resolution |
320 horizontal × 240 vertical pixels |
Waveform Style |
Vectors (dot-join), Dots, Envelope, Variable Persistence, Infinite Persistence |
Display Format |
YT and XY |
Storage Memory
Characteristic |
Description |
Reference |
4 user-definable reference traces |
Waveform |
Stores 30 internal scope records (4 traces each) with screen image and corresponding setup |
Recording |
Store 10 internal recordings that can be a 100-screen replay sequence, a Roll-mode recording, or a TrendPlot™ measurement recording |
Screen Image |
Store up to 9 internally or 256 BMP images to an external USB storage drive |
Real-time Clock |
Time and date stamp of all stored data |