Teseq NSG 3060 Burst Generator 6kV

Description

Teseq NSG 3060 Burst Generator System 6 kV Solution is a multifunction generator that simulates electromagnetic interference effects for immunity testing in conformity with international, national and manufacturers’ standards including the latest IEC/EN standards.

The NSG 3060 system is designed to fulfill conducted EMC test requirements for CE mark testing and ANSI C62.41, including Combination Wave Surge (6.6 kV), Electrical Fast Transient (EFT) pulses (4.8 kV), Ring Wave (6.6 kV), and Power Quality Testing (PQT). Expansion capabilities enable the system to be configured for a much broader range of applications including Telecom Surge 10/700 and Magnetic Field tests.

Features

  • Modular, expandable system
  • Surge, EFT/Burst, Power Quality, Ring Wave, and more
  • Surge voltage up to 6.6 kV for overtesting
  • ANSI and IEC coupling methods
  • Intuitive 7.2” color touch screen interface
  • Expert mode for changing parameters while test is running (diagnostics)
  • Status LEDs
  • Safety connectors
Download Data Sheet
Print
Email

Specifications

Combination wave pulse 1, 2/50 – 8/20 μs (Hybrid-Surge pulse)
Pulse conforms to IEC/EN 61000-4-5 and ANSI (IEEE) 62.41

Parameter Value
Pulse voltage (open circuit) ±200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit) ±100 A to 3.3 kA
Impedance 2/12 Ω
Polarity positive / negative / alternate
Pulse repetition 5* to 20 s, up to 600 s (in 1 s steps)
* derated depending on selected pulse voltage and EUT supply voltage
Test duration 1 to 9999 pulses, continuous
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / external

Burst (EFT) 5/50 ns
Pulse conforms to IEC/EN 61000-4-4

Parameter Value
Pulse amplitude ±200 V to 4.8 kV (in 1 V steps) – open circuit
±100 V to 2.4 kV (50 Ω matching system)
Burst frequency 100 Hz to 1000 kHz
Polarity positive / negative / alternate
Repetition time 1 ms to 4200 s (70 min)
Burst time 1 μs to 1999 s, single pulse, continuous
Test duration 1 s to 1000 h
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / external

Dips & drops
Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29

Parameter Value
Dips & drops From EUT voltage input to 0 V, 0%
Uvar with optional variac depending on model (VAR 650x)
Uvar with step transformer 0, 40, 70, 80% (INA 650x)
Peak inrush current capability 500 A (at 230 V)
Switching times 1 to 5 μs (100 Ω load)
Event time 20 μs to 1999 s, 1 to 99’999 cycles
Test duration 1 s to 70’000 min, 1 to 99’999 events, continuous
Repetition time 40 μs to 35 min, 1 to 99’999 cycles
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)

Ringwave 0.5 μs/100 kHz
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41

Parameter Value
Pulse voltage (open circuit) ± 200 V to 6.6 kV (in 1 V steps)
Pulse current (short circuit) ±16.6 to ±550 A, ±10%
±6.6 to ±220 A, ±10%
±1 to ±33 A, ±10%
Impedance 12/30/200 Ω
Polarity positive / negative / alternate
Pulse repetition 5* to 20 s, up to 600 s (in 1 s steps)
* derated depending on selected pulse voltage and EUT supply voltage
Test duration 1 to 9999 pulses, continuous
Phase synchronization asynchronous, synchronous 0 to 359º (in 1º steps)
Coupling ANSI / IEC / external
Stay informed