EM TEST ACS 500N3 Single Phase AC Voltage Source 3 kVA
Description
EM TEST ACS 500N3 Single Phase AC Voltage Source 3 KVA is specifically designed for harmonics and flicker testing. It meets the corresponding specifications as per EN/IEC 61000-3-2 and EN/IEC 61000-3-3 as well as JIS C 61000-3-2.
As per standard requirements a pure voltage is needed for measurements of harmonics and flicker. The output voltage of the ACS 500N3 is guaranteed to be sinusoidal with a very low distortion (THD) of less than 0.1% regardless of the load. Furthermore, the voltage is kept stable within 0.1% independent of the load, even if the load is variable.
The ACS 500N3 AC voltage source is electronically protected against Overtemperature, Overcurrent, Overvoltage and Undervoltage.
Features
- Frequency (fund.) 10Hz .. 80Hz
- Very low distortion (THD)
- Very high voltage stability
- Output power 3,000VA
- Output voltage max. 300V
- High overcurrent capability
- Inrush current capability
- Remote controlled by the DPA 500N via RS232
Specifications
OUTPUT | |
Voltage range | 0V to 300V |
Voltage resolution | 0.025% (12 bit) |
Output frequency | 10Hz to 80Hz |
Frequency resolution | 0.02Hz |
Frequency accuracy, stability | 100ppm |
Output power | 3,000VA |
Output | Safety laboratory connector |
Output current, 50Hz | Continuous: 12.1A maximum
RMS (max. 3s): 21.8A Repetitive peak: 80A |
Output current, 60Hz | Continuous: 12.5A maximum
RMS (max. 3s): 22A Repetitive peak: 80A |
INPUT | |
Supply voltage | 230V (P,N,PE) |
Input current | 25A |
Line frequency | 45Hz – 65Hz |
Fuse | 25A internal |
Connector | Sockets |
CONTROL | |
Interface | RS 232, 9-pin SubD |
DIMENSIONS | |
Housing | 19″, 6HU |
Weight | 23kg |
Size | 287mm x 449mm x 500mm |