EM TEST CNI 501x-series 1-Phase Coupling/Decoupling Networks 10kV

Description

CNI 501x-series Combined 1-Phase Coupling/Decoupling Networks for Burst and Surge Testing up to 10 kV

EM TEST CNI 501x-series 1-Phase Coupling/Decoupling Networks are used to couple EFT/Burst pulses and Surge pulses on to AC and/or DC supply lines.

The CNI 501x-series coupling/decoupling networks are fully compliant meeting the standard requirements of IEC/EN 61000-4-4 and IEC/EN 61000-4-5. Residual voltage levels are carefully considered as well as the value of the decoupling inductors to meet the requirements regarding voltage drop at the rated current of each type of CDN.

The CNI 501Bx series also fully complies with the surge test requirements outlined in ANSI/IEEE C62.41.

 

MODEL OVERVIEW

CNI 501 S1 250V, 100A AC, 75V, 100A DC up to 5.5 kV
CNI 501B S1 250V, 32A AC up to 7 kV
CNI 501B S2 300V, 16A AC, 1,000V, 16A DC up to 7 kV
CNI 501B S3 300V, 32A AC, 1,000V, 32A DC up to 7 kV
CNI 501B S4 300V, 63A AC, 1,000V, 63A DC up to 7 kV
CNI 501B9 250V, 100A AC, 75V, 100A DC up to 7 kV

Features

  • Combined coupler for EFT/Burst and Surge testing
  • Surge as per ANSI/IEEE C62.41 (models CNI 501Bx only)
  • LEDs indicate active mode and coupling
  • Automatic selection of Surge impedance
  • Fully remote controlled by EM TEST generators
  • Meets requirements up to 1,000V DC
Download Data Sheet
Print
Email

Specifications

TECHNICAL DETAILS (5.5KV MODELS)
CNI 501 S1, 5.5KV
Single phase CDN according to EN/IEC 61000-4-4 and EN/IEC 61000-4-5 for Burst up to 5.5kV

Surge up to 5kV

EUT supply 250V, 100A AC

48V, 100A DC

Dimensions Size 19″ / 6 HU
Weight approx. 55kg
TECHNICAL DETAILS (7KV MODELS)
CNI 501B S1, 7KV
Single phase CDN according to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and ANSI/IEEE C62.41 for Burst up to 5.5kV

Surge up to 7kV

EUT supply 250V, 32A AC
Dimensions Size 19″ / 6 HU
Weight approx. 20kg
CNI 501B S2, 7KV
Single phase CDN according to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and ANSI/IEEE C62.41 for Burst up to 5.5kV

Surge up to 7kV

EUT supply 300V, 16A AC

1,000V, 16A DC

Dimensions Size 19″ / 6 HU
Weight approx. 25kg
CNI 501B S3, 7KV
Single phase CDN according to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and ANSI/IEEE C62.41 for Burst up to 5.5kV

Surge up to 7kV

EUT supply 300V, 32A AC

1,000V, 32A DC

Dimensions Size 19″ / 6 HU
Weight approx. 28kg
CNI 501B S4, 7KV
Single phase CDN according to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and ANSI/IEEE C62.41 for Burst up to 5.5kV

Surge up to 7kV

EUT supply 300V, 63A AC

1,000V, 63A DC

Dimensions Size 19″ / 6 HU
Weight approx. 32kg
TECHNICAL DETAILS (10KV MODEL)
CNI 501B9, 7KV
Single phase CDN according to EN/IEC 61000-4-4, EN/IEC 61000-4-5 and ANSI/IEEE C62.41 for Burst up to 5.5kV,

Surge up to 7kV

EUT supply 250V, 100A AC

75V, 100A DC

Dimensions Size

(HxWxD)

19” / 6 HU

286 x 448 x 503 (mm)

Weight approx. 25kg
Mains Supply: 230VAC +10%/-15%

Frequency: 50/60Hz

Fuses: 2 x T 2AT

Power: approx. 70W

GENERAL DATA
COUPLING MODES
IEC 61000-4-4 Line(s) to Reference Ground; all combinations
IEC 61000-4-5 Line to Line with a 2ohm source impedance

Line(s) to PE with a 12ohm source impedance

ANSI/IEEE C62.4 (supporting models only)

Surge coupling with a 2ohm source impedance for all lines

Stay informed