EM TEST DPA 503N Digital Power Analyzer for Harmonics & Flicker Testing

Description

EM TEST DPA 503N 3-Phase Digital Power Analyzer is a fully compliant analyzer for harmonics and flicker as per the latest IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 as well as IEC/EN 61000-3-11 and IEC/EN 61000-3-12:2011 requirements.

The DPA 503N has six independent input channels; three for voltage and three for current. It follows the design specifications as per IEC/EN 61000-4-7:2002 and Am.1:2008 (for Class A instruments) for harmonics analyzers and IEC/EN 61000-4-15:2010 for flicker meters.

The DPA 503N is used for 3-phase applications but also supports single phase applications.

Features

  • Real-time data acquisition
  • Internal hard disk for data storage
  • 16-Bit A/D converter
  • 6 input channels
  • Wide-range current input up to 140Arms
  • Wide-range voltage input up to 530Vrms
  • High-sophisticated analyzing capability
  • USB interface for control and data transfer
Download Data Sheet
Print
Email

Specifications

MEASURING SYSTEM
Input channels 2 6 (3x current & 3x voltage)
Frequency range 15Hz – 3,000Hz
A/D converter 16 Bit
Controller Embedded processor Pentium

200MHz

Signal processor Motorola DSP
Memory Internal hard disk
Category Class I as per IEC/EN 61000-4-7
VOLTAGE INPUT
Input range 10V – 530V rms
Overload 4,000V peak
Accuracy Better than 0.4% of reading
CURRENT INPUT
Input range external Depending on CT model used.

Max. 140A with delivered CT

Accuracy external CT Related to 16A

2 turns better than 0.8%

5 turns better than 0.6%

GENERAL DATA
Temperature 0°C – 40°C
Rel. humidity 10% – 90%, non-condensing
Power supply 85V – 255V, 47Hz – 63Hz
Power Max. 50W
Dimension 19″ 3HU: 133mm x 449mm x 500mm
Weight 12kg
Insulation Input to case 3kV rms
Interface USB for control and data transfer