EM TEST TSS 500N6B Telecom Surge Generator

Description

TSS 500N6B Telecom Surge Generator as per Bellcore/Telcordia GR-1089-Core

EM TEST TSS 500N6B Telecom Surge Generator is specifically designed for testing 4-wire applications as per Bellcore GR-1089-Core. This standard includes several test pulses with different source impedance values to generate the pulses required by Bellcore for First Level Lightning and Intra-Building Lightning Surge tests as well as for AC power port testing. All test pulses are generated by means of a single tester.

The TSS 500N6B has a built-in CDN to connect the telecom ports (both for 2-wire and 4-wire applications). The internal switching circuit automatically sets the generator to apply the test pulses according to the selected coupling mode. The TSS 500N6B also supports testing of 12 pair telecom ports simultaneously with the test pulse 10/360µs using the optional CNB 500.

 

MODEL OVERVIEW

TSS 500N2F Telecom Surge Generator for Surge A pulses as per FCC part 68
TSS 500N4 Telecom Surge Generator as per ITU/FCC up to 4 kV
TSS 500N10 Telecom Surge Generator as per ITU / FCC up to 10 kV

Features

  • Compact Tester for Bellcore/Telcordia GR-1089-CORE
  • Test pulses for 4-wire telecom applications
  • Also covers 2-wire telecom port testing
  • Generates test pulses 10/360µs, 10/1,000µs and 2/10µs
  • Includes all necessary matching resistors
  • Built-in coupling network
  • Supports testing 12 pairs (10/360µs)
  • Manual operation
  • Standard Test routines
  • USB and GPIB interface
Download Data Sheet
Print
Email

Specifications

TECHNICAL DETAILS
FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 10/1,000US (600V)
Voltage (o.c.) 50V – 600V -0/+15%

positive/negative

Current (s.c.) 8A – 100A per wire
Rise time 10μs +0us/-4μs
Pulse duration 1,000μs +500μs/-0μs
Repetition rate 1 pulse every 36s at 600V/100A per wire
FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 10/1,000US (1,000V)
Voltage (o.c.) 50V – 1,000V -0/+15%

positive/negative

Current (s.c) 5A – 100A per wire
Rise time 10μs +0μs/-4μs
Pulse duration 1,000μs +500μs/-0μs
Repetition rate 1 pulse every 60s at 1,000V
FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 10/360US (1,000V)
Voltage (o.c.) 50V – 1,000V -0/+15%

positive/negative

Current (s.c.) 5A – 100A per wire
Rise time 10μs +0μs/-2.5μs
Pulse duration 360μs +108μs/-0μs
Repetition time 1 pulse every 20s at 1,000V
FIRST LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (2,500V)
Voltage (o.c.) 100V – 2,500V -0/+20%

positive/negative

Current (s.c) 20A – 500A per wire
Rise time 2μs +0μs/-1μs
Pulse duration 10μs +7μs/-0μs
Repetition rate 1 pulse every 5s at 2,500V
INTRA BUILDING LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (800V)
Voltage (o.c.) 100V – 800V -0/+20%

positive/negative

Current (s.c.) 12.5A – 100A per wire
Rise time 2μs +0μs/-1μs
Pulse duration 10μs +7μs/-0μs
Repetition rate 1 pulse every 2s at 800V/100A per wire
INTRA BUILDING LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (1,500V)
Voltage (o.c.) 100V – 1,500V -0/+20%

positive/negative

Current (s.c.) 6A – 100A per wire
Rise time 2μs +0μs/-1μs
Pulse duration 10μs +7μs/-0μs
Repetition rate 1 pulse every 3s at 1,500V/100A per wire
SECOND LEVEL LIGHTNING FOR 4-WIRE PORTS, PULSE 2/10US (5,000V)
Voltage (o.c.) 100V – 5,000V -0/+20%

positive/negative

Current (s.c.) 10A – 500A per wire
Rise time 2μs +0μs/-1μs
Pulse duration 10μs +7μs/-0μs
Repetition rate 1 pulse every 10s at 5,000V
INTERFACE
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
GENERAL DATA
Dimensions 19″/9HU
Weight approx. 45kg
Supply voltage 115/230V +10/-15%
Fuses 2xT2AT (230V) or 2xT4AT (115V)
Stay informed