EM TEST UCS 500N5V Combination Wave Generator

Description

UCS 500N5V Combination Wave (Surge only) Generator up to 5kV as per IEC/EN 61000-4-5

EM TEST UCS 500N5V Combination Wave Generator is designed as a Surge generator only. It is a full performing Surge tester as per IEC/EN 61000-4-5 with the best benefit-to-cost ratio yet upgradeable to include other test abilities such as EFT/Burst and PowerFail. The UCS 500N5V has a built-in single-phase coupler 300V/16A AC/DC extendable for testing three-phase DUTs by means of automatically controlled external coupling networks up to 100A. The UCS 500N5V offers an extended test voltage/current range up to 5kV/2.5kA for testing beyond basic requirements for development testing as well as fully-compliant standard tests as per IEC/EN 61000-4-5.

 

MODEL OVERVIEW

UCS 500N5 Transient Generator for EFT/Burst, Surge & Power Fail up to 5.5 kV per IEC/EN 61000-4-4, 61000-4-5 and 61000-4-11
UCS 500N5E Electrical Fast Transient /Burst Generator up to 5.5 kV as per IEC/EN 61000-4-4
UCS 500N5P Power Fail Simulator for Dips & Short Interruptions as per IEC/EN 61000-4-11 and 61000-4-29

Features

  • Fully compliant to IEC 61000-4-5
  • Surge voltage up to 5kV
  • Surge current up to 2.5kA
  • Built-in single phase coupler 300V/16A
  • Programmable current limiters
  • Monitor outputs for peak voltage and peak current
  • Standard and user test routines
  • Manual operation from front panel
  • USB and GPIB-Bus for remote control
  • Fail inputs
  • Control of external three-phase couplers
  • Pulse magnetic field tests with optional accessories
Download Data Sheet
Print
Email

Specifications

As per EN/IEC 61000-4-5 and EN 61000-6-1, -6-2
Voltage (o.c.) 160V – 5,000V ± 10%
Pulse front time 1.2us ± 30%
Pulse time to half value 50us ± 20%
Current (s.c.) Max. 2,500A ± 10%
Pulse front time 8us ± 20%
Pulse time to half value 20us ± 20%
Polarity Positive/negative/alternating
Event counter 1 – 30,000 or endless, selectable
OUTPUTS
Direct Via HV connectors for external coupling networks (Zi = 2ohm with optional adapter IMN 2)
Coupling mode Line to line

Line(s) to ground

DUT supply AC: 300V/16A; 50/60Hz

DC: 300V/16A

CRO trigger 5V trigger signal for oscilloscope
Interfaces
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
CN interface 15pin SubD connector to control an external coupling network
Fail inputs DUT monitoring via Fail1 and Fail2 input (one each)
MAINS
Supply voltage 115V/230VAC +10%/-15%
Power approx. 75W
Frequency 50/60Hz
Fuses 2 x T 2AT (230V) or 2 x T 4AT (115V)