EM TEST UCS 500N7 Transient Generator
Description
UCS 500N7 – Enhanced Ultra Compact Tester as per IEC 61000-4-x and ANSI/IEEE C62.41
EM TEST UCS 500N7 Transient Generator covers transient and power fail requirements according to international standards (basic and generic standards) and product/ product family standards with voltage capability of up to 7.0 kV. Apart from the IEC/EN 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and ringwave testing.
The UCS 500N7 includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements. Surge can be test up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.
MODEL OVERVIEW
UCS 500N7.2 Enhanced Ultra Compact Tester as per IEC 61000-4-x and ANSI/IEEE C62.41 for Renewable Energy
Features
- Ultra-Compact Simulator up to 7.0kV
- Burst module (IEC/EN 61000-4-4)
- Surge module (IEC/EN 61000-4-5 Ed 3.0/-9)
- PowerFail module (IEC/EN 61000-4-11)
- Ringwave module (IEC/EN 61000-4-12) optional
- Telecom Surge Module (IEC/EN 61000-4-5) optional
- Magnetic field tests with optional accessories
- Built-in single-phase coupler 300V/16A
- USB and GPIB-Bus for remote control
- Manual operation from front panel
- Monitor outputs for peak voltage and peak current
- Fail inputs
- External variac control 0-10Vdc
- Control of external three-phase couplers
Specifications
ELECTRICAL FAST TRANSIENTS | |
BURST MODULE EFT/N7 | As per EN/IEC 61000-4-4 and EN 61000-6-1, -6-2 |
Test voltage | 200V – 5,500V ± 10%
100V – 2,750V ± 10% into 50ohm |
Pulse shape | 5/50ns into 50ohm and 1,000ohm |
Rise time tr | 5ns ± 30% into 50ohm
5ns ± 30% into 1,000ohm |
Pulse width td | 50ns ± 30% into 50ohm
50ns -15/+100ns into 1,000ohm |
Source impedance | 50ohm |
Polarity | Positive/negative |
COMBINATION WAVE / SURGE | |
Surge Module VCS/N7 | As per EN/IEC 61000-4-5 and EN 61000-6-1, -6-2 |
Voltage (o.c.) | 250V – 7,000V ± 10% |
Pulse front time | 1.2us ± 30% |
Pulse time to half value | 50us ± 20% |
Current (s.c.) | Max. 3,500A ± 10% |
Pulse front time | 8us ± 20% |
Pulse time to half value | 20us ± 20% |
Polarity | Positive/negative/alternating |
Event counter | 1 – 30,000 or endless, selectable |
POWER FAIL, DIPS & INTERRUPTIONS, VOLTAGE VARIATIONS | |
Power Fail Module PFS/N7 | As per EN/IEC 61000-4-11, and EN 61000-6-1, -6-2 |
Channel PF1/PF2 | AC voltage: max. 300V
AC current: max. 16A |
Frequency | 16Hz – 500Hz |
Switching time | < 5us into a 100ohm resistive load |
Inrush current | > 500A |
Protection | Both channels are protected against short-circuit conditions. |
GENERAL DATA | |
INTERFACES | |
Serial interface | USB |
Parallel interface | IEEE 488, addresses 1 – 30 |
Analog output | 0 – 10VDC to control an external transformer |
CN interface | 15pin SubD connector to control an external coupling network |
Fail inputs | DUT monitoring via Fail1 and Fail2 input (one each) |
MAINS | |
Supply voltage | 115/215 VAC + 10%/-15 |
Power consumption | Approx. 75W |
Frequency | 50/60 Hz |
Fuses | 2x 2 AT (230V or 2x 4 AT (115V) |
DIMENSIONS | |
Housing | 19″, 6HU |
Weight | approx. 29kg |
- ANSI/IEEE Standards
- ANSI/IEEE C62.41
- Basic Standards
- IEC 61000-4-11
- IEC 61000-4-12
- IEC 61000-4-29
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- Telecom Standards
- ITU-T K.20
- ITU-T K.21
- ITU-T K.45
- Product Standards
- EN 61543
- IEC 60255-22-5
- IEC 61008-1
- IEC 61009-1
- IEC 61326-1
- IEC 61850-3
- UL Standards
- UL 1741
- UL 244A
- UL 943
- Generic Standards
- EN 61000-6-1
- EN 61000-6-2
- Automotive OEM Specifications
- UNECE R10 (Automotive)
- International Standards
- IEEE 1547