EM TEST UCS 500N7 Transient Generator

Description

UCS 500N7 – Enhanced Ultra Compact Tester as per IEC 61000-4-x and ANSI/IEEE C62.41

EM TEST UCS 500N7 Transient Generator covers transient and power fail requirements according to international standards (basic and generic standards) and product/ product family standards with voltage capability of up to 7.0 kV. Apart from the IEC/EN 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and ringwave testing.

The UCS 500N7 includes everything necessary to conduct fully compliant tests at levels that go far beyond common test requirements. Surge can be test up to 7.0kV either according to IEC/EN 61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an integrated Ringwave module (optional) as per ANSI/IEEE C62.41 and IEC/EN 61000-4-12 for ringwave tests on mains supply lines.

 

MODEL OVERVIEW

UCS 500N7.2 Enhanced Ultra Compact Tester as per IEC 61000-4-x and ANSI/IEEE C62.41 for Renewable Energy

Features

  • Ultra-Compact Simulator up to 7.0kV
  • Burst module (IEC/EN 61000-4-4)
  • Surge module (IEC/EN 61000-4-5 Ed 3.0/-9)
  • PowerFail module (IEC/EN 61000-4-11)
  • Ringwave module (IEC/EN 61000-4-12) optional
  • Telecom Surge Module (IEC/EN 61000-4-5) optional
  • Magnetic field tests with optional accessories
  • Built-in single-phase coupler 300V/16A
  • USB and GPIB-Bus for remote control
  • Manual operation from front panel
  • Monitor outputs for peak voltage and peak current
  • Fail inputs
  • External variac control 0-10Vdc
  • Control of external three-phase couplers
Download Data Sheet
Print
Email

Specifications

ELECTRICAL FAST TRANSIENTS
BURST MODULE EFT/N7 As per EN/IEC 61000-4-4 and EN 61000-6-1, -6-2
Test voltage 200V – 5,500V ± 10%

100V – 2,750V ± 10% into 50ohm

Pulse shape 5/50ns into 50ohm and 1,000ohm
Rise time tr 5ns ± 30% into 50ohm

5ns ± 30% into 1,000ohm

Pulse width td 50ns ± 30% into 50ohm

50ns -15/+100ns into 1,000ohm

Source impedance 50ohm
Polarity Positive/negative
COMBINATION WAVE / SURGE
Surge Module VCS/N7 As per EN/IEC 61000-4-5 and EN 61000-6-1, -6-2
Voltage (o.c.) 250V – 7,000V ± 10%
Pulse front time 1.2us ± 30%
Pulse time to half value 50us ± 20%
Current (s.c.) Max. 3,500A ± 10%
Pulse front time 8us ± 20%
Pulse time to half value 20us ± 20%
Polarity Positive/negative/alternating
Event counter 1 – 30,000 or endless, selectable
POWER FAIL, DIPS & INTERRUPTIONS, VOLTAGE VARIATIONS
Power Fail Module PFS/N7 As per EN/IEC 61000-4-11, and EN 61000-6-1, -6-2
Channel PF1/PF2 AC voltage: max. 300V

AC current: max. 16A

Frequency 16Hz – 500Hz
Switching time < 5us into a 100ohm resistive load
Inrush current > 500A
Protection Both channels are protected against short-circuit conditions.
GENERAL DATA
INTERFACES
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
Analog output 0 – 10VDC to control an external transformer
CN interface 15pin SubD connector to control an external coupling network
Fail inputs DUT monitoring via Fail1 and Fail2 input (one each)
MAINS
Supply voltage 115/215 VAC + 10%/-15
Power consumption Approx. 75W
Frequency 50/60 Hz
Fuses 2x 2 AT (230V or 2x 4 AT (115V)
DIMENSIONS
Housing 19″, 6HU
Weight approx. 29kg