EM TEST VCS 500N10T Telecom Surge Generator

Description

VCS 500N10T Combined Combination Wave and Telecom Surge Generator up to 10KV

EM TEST VCS 500N10T Combination Wave / Telecom Surge Generator unifies the test capabilities for Combination wave surge and telecom surge testing in one unit up to 10kV per test requirements of IEC/EN 61000-4-5 and IEC/EN 61000-4-9. Moreover, it offers built-in coupling resistors for telecom port testing.

For combination wave surge tests on high-current mains supply lines its capability can be extended by an external CDN to achieve nominal currents of 100A and more per phase. To comply with safety regulations the VCS 500N10T is equipped with a contact to control warning lamps and with a safety interlock.

 

MODEL OVERVIEW

VCS 500N7T Compact surge / Telecom surge generator with integrated CDN up to 7kV

Features

  • Combination Wave up to 10kV/5kA
  • Telecom surge voltage up to 10kV
  • Telecom surge current up to 666A
  • Repetition rate 60s @10kV Surge
  • Built-in coupling for telecom port testing
  • USB (optical link) and GPIB interface
  • Interlock
  • Warning lamp control
  • Manual operation
  • Voltage/current monitors
Download Data Sheet
Print
Email

Specifications

SURGE GENERATOR
AC POWER PORT TESTING, PULSE 1.2/50US – 8/20US AS PER IEC 61000-4-5
Voltage (o.c.) 500V – 10,000V ±10%
Rise time 1.2us ± 30%
Pulse duration 50us ± 20%
Current (s.c.) 250A – 5,000A
Rise time 8us ± 20%
Pulse duration 20us ± 20%
Polarity Positive, negative or alternating
Counter 1 – 30,000 or endless
TELECOM PORT TESTING, PULSE 10/700US – 4/300US AS PER IEC 61000-4-5
Voltage (o.c.) 500V – 10,000V ±10%
Rise time 10us ± 30%
Pulse duration 700us ± 20%
Current (s.c.) 12.5A – 250A
Rise time 5us ± 20%
Pulse duration 320us ± 20%
Energy storage capacitor 20uF
Source impedance 40ohm (15ohm from generator and 25ohm at Tx)
Polarity Positive, negative or alternating
Counter 1 – 30,000 or endless
TELECOM TESTING PULSE 10/700US AS PER ITU AND ETS RECOMMENDATIONS
Voltage (o.c.) 500V – 10,000V ±10%
Rise time 10us ± 30%
Pulse duration 700us ± 20%
Energy storage capacitor 20uF
Polarity Positive, negative or alternating
Counter 1 – 30,000 or endless
PULSE OUTPUT
Direct Outputs with HV connectors:

– Zi = 2ohm : 1.2/50us – 8/20us

– Zi = 15ohm : 10/700us – 5/320us

– for external couplers

INTERFACE
Optical interface Opto link, 3m cable

USB A connector

Parallel interface IEEE 488, addresses 1 – 30
CN interface To control external coupling matrix
GENERAL DATA
Dimensions 19″/12HU
Weight approx. 44kg
MAINS
Supply voltage 115/230V +10/-15%
Fuses 2x T2AT (230) or 2x T4AT (115V)
Stay informed