Bruel & Kjaer Type 2240 - Sound Level Meter
Description
A low-cost, Class 1 sound level meter conforming to international standards. The three-button user-interface and large digital display make it easy to use for on-the-spot measurements. Equipped with a Type 4188 microphone, it simultaneously measures all of the most important environmental noise parameters over a measurement period from 1 second to 60 minutes.
Features
- Class 1 measurement precision conforming to the latest standards
- LAeq, LAFmax, LCpeak, LAF
- Dynamic range: 30 – 140 dB in two 80 dB ranges
- Handy and lightweight
- Large and clear display
- 16 hour battery life from two AA cells
Specifications
STANDARDS |
Conforms with the following: |
• IEC61672 – 1:2002 Class 1 |
• IEC60651 Type 1 (1979) with amendments 1 and 2 |
• IEC60804 Type 1 (2000) |
• ANSIS1.4 – 1983 Type S1 |
• ANSIS1.43 – 1997 Type 1 |
PARAMETERS |
Four parameters are measured simultaneously: |
• LAF, instantaneous sound pressure level, frequency weighting ‘A’ and time weighting ‘F’ |
• LAFmax, maximum sound pressure level, frequency weighting ‘A’ and time weighting ‘F’ |
• LAeq, equivalent continuous sound pressure level, frequency weighting ‘A’ |
• LCpeak, maximum peak sound pressure level, frequency weighting ‘C’ |
Resolution: 0.1 dB for all four parameters |
MEASUREMENT CONTROL |
Measurements are manually controlled |
Measurement times between 1 s and 60 min |
MEASURING RANGES |
RMS: Total range: 30 – 140 dB |
Two manually selected ranges: 30 – 110 dB and 60 – 140 dB |
Peak: 60 – 143 dB |
NOISE FLOOR |
Below measurement range, < 22 dB |
DETECTORS |
Simultaneous RMS and Peak with independent frequency weightings |
Linear Operating Range: 80 dB |
FREQUENCY RANGE |
20Hz to 16 kHz |
FREQUENCY WEIGHTINGS |
A-weighting (RMS) |
C-weighting (Peak) |
TIME WEIGHTING |
‘F’ (Fast) |
OVERLOAD AND UNDER-RANGE INDICATORS |
Overload is indicated at full-scale +0.3 dB |
An overload detected during a timed measurement latches and is displayed with the relevant parameters until these are cleared Under-range is indicated at scale lower limit –0.5 dB |
MICROPHONE |
Type 4188 Prepolarized Free-field 1/2″ Condenser Microphone |
Sensitivity: –30 dB re 1V/Pa } 2 dB (corresponding to 31.6mV/Pa) |
Frequency Range: 8Hz to 16 kHz }2dB |
DISPLAY |
LCD showing: |
• Input signal level – indicated with a quasi-analogue bar |
• Selected parameters with level |
• Warnings for: low battery, measurement in progress, overload and under-range |
• Measuring range |
• Frequency and time weighting |
• Elapsed measurement time |
Update Cycle: 1 s (numeric), 0.1 s (bar graph) |
Elapsed Time Display: from 00 min 00 s up to 60 min 00 s |
SETTLING TIME |
Less than 5 s |
REFERENCE CONDITIONS |
Reference Frequency: 1000 Hz |
Reference Sound Pressure Level: 94 dB |
Reference Temperature: 20°C (68°F) |
Reference RH: 65% |
Reference Range: 30 – 110 dB |
Reference Direction of Incidence: Frontal |
ENVIRONMENTAL EFFECTS |
Storage Temperature: –25 to 60°C (–13 to 140°F) |
Operating Temperature: –10 to 50°C (14 to 122°F) |
Effect of Magnetic Field: 80 A/m (1 oersted) at 50 Hz gives less than 30 dB (A-weighted) |
BATTERIES |
Two 1.5 V LR 6/AA-size alkaline batteries |
Power Consumption During Normal Operation: Less than 300mW |
Lifetime (at room temperature): Approximately 16 h |
PHYSICAL CHARACTERISTICS |
Dimensions: 230 × 78 × 31 mm including microphone |
Weight: 245 g (8.64 oz) including batteries |