AE Techron T 2000 Low-Frequency Conducted Susceptibility Transformer
Description
AE Techron T 2000 Low-Frequency Conducted Susceptibility Transformer is designed to meet or exceed the LF conducted susceptibility test requirements of DO 160 Section 18. The T 2000 is used to apply the required test signals to the lines under test for ripple voltage tests and continuous or transient conducted immunity tests. It may also be used as a 2-to-1 step-down transformer. The secondary can support up to 40AP.
The T 2000 transformer supports up to 200W and can pass up to 40AP on the secondary. The turns ratio provides a 2-to-1 step down.
The T 2000 provides convenient input connectors via binding posts. Standard 0.75-inch spacing of binding posts allows use of standard plugs. Output is via Multi Contact 125A plugs.
A thermal breaker protects the unit against over-current conditions on the primary. A 35 ARMS breaker protects the unit against over-current conditions on the secondary. A rugged, impact-resistant case and robust design protects the transformer from accidental damage.
Features
- Frequency response: 10 Hz to 250 kHz
- Up to 200W audio power
- Up to 40 Ap AC or DC secondary current
- Two-to-one step-down
- Output via Multi Contact 125A plugs; mating connectors included
Specifications
Technical | ||
Transformer DC Resistance | ||
Primary | 0.076 ohms | |
Secondary | 0.021 ohms | |
Frequency Response | 10 Hz to 250 kHz | |
Audio Power | 200W MAX | |
Dielectric Test | 1500 VDC | |
Turns Ratio | Two-to-one step down | |
Secondary Inductance | Approximately 0.6 mH (unloaded) | |
Protection | Input power-protected via thermal breaker; secondary winding protected via 35ARMS breaker | |
Controls and Connectors | ||
Input Terminals | 4-way binding posts | |
Output Terminals | Multi Contact 125A plugs | |
Circuit Breaker | Secondary winding limited to 35 ARMS via circuit breaker; push to reset | |
Physical Characteristics | ||
Case | Steel interior shell with a durable external shell made from high-density polyethylene for impact resistance. | |
Operating Conditions | Temperature | 10°C to 40°C (50°F to 104°F) |
Humidity | 70% or less, non-condensing | |
Recommended Ambient Temperature | 27°C (77°F) | |
Cooling | Natural air convection | |
Weight | 15 lbs. (6.8 kg) | |
Dimensions (WxDxH) | 5.25 in. x 10.375 in. x 9.75 in. (13.3 cm x 26.4 cm x 24.8 cm) |