Sorensen DCS 60-20E Programmable DC Power Supply 60V 20A 1200W
Description
Sorensen DCS 60-20E Programmable DC Power Supply 60V 20A 1200W is ideally suited for a wide range of applications requiring DC power in a small form factor. Applications range from manufacturing test and burn-in of automotive components, avionics electronics, telecommunications and consumer products to beam steering, process control and laboratory R&D use.
The DCS Family of 1 kW, 1.2 kW and 3 kW programmable power supplies utilizes unique packaging techniques to achieve continuous full output power (1 kW, 1.2 kW or 3 kW) in any volt/amp combination within the rated output voltage and current limits in a low profile chassis, Demonstrated large installed base over a long period of time, the DCS family provides a highly reliable power platform.
This family has an easy-to-use front panel with 10-turn potentiometers to adjust voltage and current settings that are displayed simultaneously. LEDs indicate overtemperature, remote programming, shutdown and over voltage protection, status and constant-voltage/current mode operation. The DCS 3 kW Models have push button control of the output standby mode, OVP reset, remote/local programming and preview status of voltage, current and OVP setpoints.
The DCS family can also be controlled remotely. Four analog control modes are standard as well as isolated analog control (option). Computer control can be accomplished over IEEE488.2 GPIB (option) or LXI-compliant Ethernet (option).
Features
- High power density / low ripple and noise
- High programming resolution with Ethernet interface
- Constant voltage and current mode
- Remote sensing
- Isolated analog control and monitoring (optional)
Specifications
Common | ||||||
Meter Accuracy | 1% of full scale + 1 count | |||||
Max. Voltage Differential from Output to Safety Ground | 150 VDC | |||||
Remote Start/Stop and Interlock | TTL compatible input or 12-250 VAC (12-130 VDC) or a contact closure | |||||
Cooling | Internal fan, over temperature shutdown if internal heat sink exceeds set temperature | |||||
Remote Sense | The maximum allowed sense line drop is 4V per line (2V on the DCS 8/10V 1 kW/1.2 kW models and 1V/line for all 3 kW models). Line drop subtracts from the maximum available output voltage at full rated power. | |||||
Remote Programming | Enabled via external jumper on rear panel connector J3 | |||||
Overvoltage Protection | Crowbar type adjustable from 5-110% of rated output using front panel control (local or remote program selectable via J3 jumper) | |||||
Remote Analog Programming Linearity | ±1% Accuracy: ±5% | |||||
Regulatory | Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive) | |||||
Input: Voltage and Frequency | ||||||
Output Power |
200 – 250 VAC |
100 – 132 VAC |
||||
1.2kW |
single phase, 9A typical, 47- 63 Hz |
single phase, 18A typical, 47-63 Hz, internal jumper selectable |
||||
Output: Voltage and Current | ||||||
1.2kW Model |
Voltage |
Current |
||||
DCS 8-140E |
0 – 8 |
0 – 140 |
||||
DCS 10-120E |
0 – 10 |
0 – 120 |
||||
DCS 20-60E |
0 – 20 |
0 – 60 |
||||
DCS 33-36E |
0 – 33 |
0 – 36 |
||||
DCS 40-30E |
0 – 40 |
0 – 30 |
||||
DCS 50-24E |
0 – 50 |
0 – 24 |
||||
DCS 60-20E |
0 – 60 |
0 – 20 |
||||
DCS 80-15E |
0 – 80 |
0 – 15 |
||||
DCS 100-12E |
0 – 100 |
0 – 12 |
||||
DCS 150-8E |
0 – 150 |
0 – 8 |
||||
DCS 300-4E |
0 – 300 |
0 – 4 |
||||
Output | ||||||
Voltage Resolution | 0.02% | |||||
Ripple (mV rms or p-p) | See table | |||||
Regulation Line | For input voltage variation over the AC input voltage range, with constant rated load. | |||||
Load | For 0-100% load variation, with constant nominal line voltage. | |||||
Voltage | 0.1% | |||||
Current | 0.1% | |||||
Transient Response | Typically recovers in 500 μs (1 & 1.2 kW) or 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change. | |||||
Stability | ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature | |||||
Efficiency | See table below Temperature Coefficient: 0.02%/°C of maximum output voltage; 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load | |||||
Physical | ||||||
Dimensions | Width: 19” (482 mm) W, Depth 17.52” (445 mm)
Height: 1 kW and 1.2 kW: 1U or 1.72” |
|||||
Weight & Shipping Weight | ||||||
Weight | 1 kW and 1.2 kW: 19 lbs. ( 8.6 kg) | |||||
Shipping Weight | 1 kW and 1.2 kW: 24 lbs. (10.9 kg) | |||||
Environmental | ||||||
Operating Temperature | 0°C to 50°C (no derating) | |||||
Storage Temperature | -55°C to 85°C | |||||
Humidity Range | 0 to 80% RH, non condensing | |||||
Programming Specifications | ||||||
DCS Series 1.2 kW |
Programming Accuracy M130/M131/M9C/M85 Options |
|||||
Voltage 0.1% + |
Current 0.1% + |
OVP 0.5% + |
||||
DCS 8-140E |
8mV |
560mA |
44mV |
|||
DCS 10-120E |
10mV |
480mA |
55mV |
|||
DCS 20-60E |
20mV |
240mA |
110mV |
|||
DCS 33-36E |
23mV |
144mA |
182mV |
|||
DCS 40-30E |
40mV |
120mA |
220mV |
|||
DCS 50-24E |
50mV |
96mA |
275mV |
|||
DCS 60-20E |
60mV |
80mA |
330mV |
|||
DCS 80-15E |
80mV |
60mA |
440mV |
|||
DCS 100-12E |
100mV |
48mA |
550mV |
|||
DCS 150-8E |
150mV |
32mA |
825mV |
|||
DCS 300-4E |
300mV |
16mA |
1650mV |
|||
Output | ||||||
DCS Series 1.2 kW |
Output Power |
|||||
Voltage VDC |
Current ADC @ 50°C |
|||||
DCS 8-140E |
0-8 |
0-140 |
||||
DCS 10-120E |
0-10 |
0-120 |
||||
DCS 20-60E |
0-20 |
0-60 |
||||
DCS 33-36E |
0-33 |
0-36 |
||||
DCS 40-30E |
0-40 |
0-30 |
||||
DCS 50-24E |
0-50 |
0-24 |
||||
DCS 60-20E |
0-60 |
0-20 |
||||
DCS 80-15E |
0-80 |
0-15 |
||||
DCS 100-12E |
0-100 |
0-12 |
||||
DCS 150-8E |
0-150 |
0-8 |
||||
DCS 300-4E |
0-300 |
0-4 |
||||
Output | ||||||
DCS Series 1.2 kW |
Constant Voltage Mode* |
|||||
Ripple (rms) ** mV |
Noise (p-p) mV |
Transient Response |
||||
DCS 8-140E |
5 |
60 |
500 |
|||
DCS 10-120E |
55 |
60 |
500 |
|||
DCS 20-60E |
5 |
60 |
500 |
|||
DCS 33-36E |
5 |
60 |
500 |
|||
DCS 40-30E |
5 |
60 |
500 |
|||
DCS 50-24E |
5 |
60 |
500 |
|||
DCS 60-20E |
5 |
60 |
500 |
|||
DCS 80-15E |
5 |
60 |
500 |
|||
DCS 100-12E |
10 |
60 |
500 |
|||
DCS 150-8E |
15 |
160 |
500 |
|||
DCS 300-4E |
25 |
200 |
500 |
|||
Output | ||||||
DCS Series 1.2 kW |
Combined Regulation Line and Load % |
Temp Coeff. Voltage % |
Voltage Drift |
|||
DCS 8-140E |
0.2 |
0.02 |
0.05 |
|||
DCS 10-120E |
0.2 |
0.02 |
0.05 |
|||
DCS 20-60E |
0.2 |
0.02 |
0.05 |
|||
DCS 33-36E |
0.2 |
0.02 |
0.05 |
|||
DCS 40-30E |
0.2 |
0.02 |
0.05 |
|||
DCS 50-24E |
0.2 |
0.02 |
0.05 |
|||
DCS 60-20E |
0.2 |
0.02 |
0.05 |
|||
DCS 80-15E |
0.2 |
0.02 |
0.05 |
|||
DCS 100-12E |
0.2 |
0.02 |
0.05 |
|||
DCS 150-8E |
0.2 |
0.02 |
0.05 |
|||
DCS 300-4E |
0.2 |
0.02 |
0.05 |
|||
Output | ||||||
DCS Series 1.2 kW |
Constant Current Mode* |
|||||
Regulation line and load % combined |
Ripple (rms)** mA |
|||||
DCS 8-140E |
0.2 |
180 |
||||
DCS 10-120E |
0.2 |
153 |
||||
DCS 20-60E |
0.2 |
30 |
||||
DCS 33-36E |
0.2 |
11 |
||||
DCS 40-30E |
0.2 |
9 |
||||
DCS 50-24E |
0.2 |
8.5 |
||||
DCS 60-20E |
0.2 |
6.6 |
||||
DCS 80-15E |
0.2 |
6 |
||||
DCS 100-12E |
0.2 |
3.6 |
||||
DCS 150-8E |
0.2 |
2.3 |
||||
DCS 300-4E |
0.2 |
1.2 |
||||
Output | ||||||
DCS Series 1.2 kW |
Input Current, A Nominal |
Efficiency % (Typ.) |
||||
230V Single Phase |
208V Three Phase |
|
||||
DCS 8-140E |
9 |
N/A |
82 |
|||
DCS 10-120E |
9 |
N/A |
82 |
|||
DCS 20-60E |
9 |
N/A |
82 |
|||
DCS 33-36E |
9 |
N/A |
84 |
|||
DCS 40-30E |
9 |
N/A |
84 |
|||
DCS 50-24E |
9 |
N/A |
84 |
|||
DCS 60-20E |
9 |
N/A |
85 |
|||
DCS 80-15E |
9 |
N/A |
85 |
|||
DCS 100-12E |
9 |
N/A |
85 |
|||
DCS 150-8E |
9 |
N/A |
85 |
|||
DCS 300-4E |
9 |
N/A |
85 |