E&I 3100LA RF Power Amplifier 250 kHz – 150 MHz 100W

Description

E&I 3100LA RF Power Amplifier 250 kHz – 150 MHz 100W is a rugged source of RF power, useful for RFI/EMI, HF and VHF transmitters, plasma equipment, nuclear accelerators and general laboratory applications.

FLEXIBILITY:

The 3100LA produces 100 Watts of class A linear power output over the entire frequency range from 250 kHz to 150 MHz. It has very low harmonic distortion along with low IMD products. Operation over the band is achieved without the need for any band switching or indeed any adjustments. The power gain is rated at 50 dB with a typical gain flatness of ± 1.5 dB.

RUGGEDNESS:

The 3100LA is built to withstand a +13 dBm input (1.0 Volt RMS) for any VSWR load condition. The internal switched mode power supply is very conservatively rated, to facilitate operation over a large range of line conditions and temperatures. The forced air cooling provides for low internal temperatures, providing long term reliability. The RF power is delivered by rugged DMoS FETs, de-rated to provide for excellent MTBF figures.

Features

  • 100 Watts Linear RF Power
  • 250 kHz – 150 MHz
  • Class A Linearity
  • Instantaneous Bandwidth
  • Solid State
  • Air Cooled
Download Data Sheet
Print
Email

Specifications

Primary Performance Characteristics
Start Frequency 250 kHz
Stop Frequency 150 MHz
Rated Power (P1dB) 100 W
Saturated Power Output 250 kHz to 150 MHz > 125 W

1 MHz to 100 MHz > 150 W

Power Gain 55 dB nominal
Gain Flatness ±1.5 dB
Input Power for Rated Output 1 mW
Input Impedance / VSWR 50 Ω / VSWR 1.5:1 Max
Output Impedance / VSWR 50 Ω / VSWR 1.25:1 Max
Harmonic Level < -25 dBc at 75 Watts
Ruggedness 00:1 VSWR
Stability Unconditional into any passive load
Protection Input: Unit will withstand input signal of +13 dBm without damage (1.0 V rms) maximum and infinite load VSWR.
Front Panel Meter Front panel indicates forward and reflected power.
Third Order Intercept Point IP3 ~ 59 dBm
Class of Operation Class A
Specifications
AC Input 100-240 VAC, 47-63 Hz

12A maximum at 115 VAC

6.5A at 240 Volts

Connectors Type N
Operating Temperature 0 to 40˚C
Cooling Forced Air Cooling
Front Panel Display Indicates forward and reflected power
Front Panel Accuracy ±3% of full scale accuracy
Form Factor
Weight 52 lb. (23.6 kg)
Height 8.6 in 218.2 mm
Width 16.7 in 424.4 mm
Depth 20.1 in 511 mm