Sorensen DLM 80-7.5 Programmable DC Power Supply 80V 7.5A 600W
Description
Sorensen DLM 80-7.5 Programmable DC Power Supply 80V 7.5A 600W is designed to provide continuously variable output voltage and current for a broad range of applications in a compact 1U (1.75 inches) high, half-rack (8.5 inch) wide chassis.
With the use of Zero Voltage Switching (ZVS) technology, these supplies are able to achieve exceptionally low, near-linear ripple and noise rivaling larger and more expensive linear power supplies. In addition, the high efficiency and fast load transient response assure that the DLM is ideal for even the most demanding applications.
The Sorensen DLM 600W models are ideal for high density multiple output rackmount requirements or low profile benchtop applications. Output voltages from 0-5VDC to 0-300VDC and currents from 0-2A to 0- 75A are available.
The cooling air intake is at the front and sides with exhaust at the rear and sides. Variable speed fans are controlled as a function of ambient air temperature and load, thus reducing acoustic noise and increasing fan life. This allows supplies to be stacked one directly on top of another without space in between, yielding maximum rackmount packing density and a wide operating temperature of 0-50° C. An optional rackmount kit is available to easily mount one or two units side-by-side.
The front panel layout makes the Sorensen DLM 600W series easy to use. Voltage and current can be set from individual 10-turn potentiometer knobs. Control push buttons include power on, output on, local/remote, voltage/ current preview and overvoltage protection preview. Set-point or actual voltage/ current values can be viewed on two 3-½ digit LED displays. The DLM 600W can also be controlled through IEEE488.2 GPIB (option) or LXI-compliant Ethernet (option).
Supplies can be connected in series or parallel. All models automatically accept any standard single phase input without manual set up.
Features
- High Power Density: 600 watts in 1U (1.75 inches) high, half rack (8.5 inches) wide; no top or bottom clearance spacing required.
- Near Linear Ripple & Noise Ripple as low as 2.5mV rms, noise as low as 15mV p-p.
- Remote Control
- LXI Compliant Ethernet LAN / RS-232C (16 bit)
- IEEE-488.2 / RS-232C (12 bit)
- Standard analog programming 0-5V, 0-10V, or 0-5kΩ
Specifications
Common | |||||||||||
Remote Sense | The maximum load line drop is up to the full voltage rating of the supply. The drop in the load leads subtracts from the maximum voltage available for the load except as follows: maximum rated voltage is available at the load and voltage regulation specifications apply for line drops of<1V on DLM5-75 and DLM8-75, <2V for all other DLM600 models and DLM3K/4K models rated 5V to 16V, and <5V for all other DLM3K/4K models. | ||||||||||
Remote Programming | Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0-10VDC, or 0-5kΩ | ||||||||||
Remote Monitoring | Voltage or current can be monitored with userselectable ranges, scaled to 0-5 VDC or 0-10 VDC | ||||||||||
Operational Features | Master/slave parallel operation, up to 4 units of the same model can be connected in parallel, with active current sharing control. Series operation, multiple units of the same model can be connected in series, limited by 300Vpk between both output terminal and chassis. | ||||||||||
Software | IVI-COM, LabVIEW® or LabWindow®/CVI driver for ethernet and IEEE-488.2 | ||||||||||
Regulatory Compliance | CE Compliant: • Low Voltage Directive (73/23/EEC) using EN 61010-1, and • EMC Directive (89/336/EEC) using EN 61326 Certified to UL 61010-1, CSA C22.2 No. 61010.1 and IEC/EN 61010-1 |
||||||||||
Input | |||||||||||
Voltage and Frequency | 90-132 VAC or 180-264 VAC max, auto ranging, 47-63 Hz, single phase, 2-wire plus ground |
||||||||||
Current | 11A maximum at 115VAC, 6A maximum at 230 VAC | ||||||||||
Connector | IEC 320 with detachable line cord | ||||||||||
Power Factor | 0.6, typical at full load; dependent on the impedance of the AC input. | ||||||||||
Output | |||||||||||
Line Regulation | Voltage: 0.005% of V max + 2 mV Current: 0.01% of I max + 2 mA See table for input voltage variation over the AC input voltage range, with constant rated load. |
||||||||||
Load Regulation | Voltage: 0.005% of V max + 2 mV Current: 0.02% of I max + 5 mA See table For 0-100% load variation, with constant nominal line voltage |
||||||||||
Transient Response | 500 μs to steady-state output voltage (within 0.1% of Vmax) for 50-100% or 100-50% load change | ||||||||||
Stability | ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature | ||||||||||
Efficiency | 84% typical at maximum output power; 82% typical for DLM 5-75 and DLM 8-75 | ||||||||||
Temperature Coefficient | 0.02%/°C of maximum output voltage, 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load. | ||||||||||
Physical | |||||||||||
Dimensions | Width: 8.5” (216 mm) Height: 1U or 1.75” (44 mm) Depth: 17” (432 mm) Option M6 depth 20” (508 mm) |
||||||||||
Weight & Shipping | |||||||||||
Weight | 9.7 lbs. (4.4 kg) | ||||||||||
Shipping Weight | 12.7 lbs. (5.8 kg) | ||||||||||
Output Ratings | |||||||||||
Model |
Voltage |
Current |
Power |
||||||||
DLM 5-75 |
0-5 VDC |
0-75 ADC |
375 W |
||||||||
DLM 8-75 |
0-8 VDC |
0-75 ADC |
600 W |
||||||||
DLM 10-60 |
0-10 VDC |
0-60 ADC |
600 W |
||||||||
DLM 20-30 |
0-20 VDC |
0-30 ADC |
600 W |
||||||||
DLM 40-15 |
0-40 VDC |
0-15 ADC |
600 W |
||||||||
DLM 60-10 |
0-60 VDC |
0-10 ADC |
600 W |
||||||||
DLM 80-7.5 |
0-80 VDC |
0-7.5 ADC |
600 W |
||||||||
DLM 150-4 |
0-150 VDC |
0-4 ADC |
600 W |
||||||||
DLM 300-2 |
0-300 VDC |
0-2 ADC |
600 W |
||||||||
Model |
Line Regulation |
Load Regulation |
|||||||||
Voltage (0.005% of Vmax + 2 mV) |
Current (0.01% of Imax + 2 mA) |
Voltage (0.005% of Vmax + 2 mV) |
Current (0.02% of Imax + 5 mA) |
||||||||
DLM 5-75 |
2.4 mV |
9.5 mA |
2.4 mV |
20 mA |
|||||||
DLM 8-75 |
2.4 mV |
9.5 mA |
2.4 mV |
20 mA |
|||||||
DLM 10-60 |
2.5 mV |
8 mA |
2.5 mV |
17 mA |
|||||||
DLM 20-30 |
3 mV |
5 mA |
3 mV |
11 mA |
|||||||
DLM 40-15 |
4 mV |
3.5 mA |
4 mV |
8 mA |
|||||||
DLM 60-10 |
5 mV |
3 mA |
5 mV |
7 mA |
|||||||
DLM 80-7.5 |
6 mV |
2.8 mA |
6 mV |
6.5 mA |
|||||||
DLM 150-4 |
9.5 mV |
2.2 mA |
9.5 mV |
5.8 mA |
|||||||
DLM 300-2 |
17 mV |
2.1 mA |
17 mV |
5.4 mA |
|||||||
Output Ratings | |||||||||||
GPIB (M9G/M85) |
|||||||||||
Model |
Voltage (0.2% of VMax) |
Current (0.5% of IMax) |
OVP (1% of 1.1 x VMax) |
||||||||
DLM 5-75 |
16 mV |
375 mA |
55 mV |
||||||||
DLM 8-75 |
16 mV |
375 mA |
88 mV |
||||||||
DLM 10-60 |
20 mV |
300 mA |
110 mV |
||||||||
DLM 20-30 |
40 mV |
150 mA |
220 mV |
||||||||
DLM 40-15 |
80 mV |
75 mA |
440 mV |
||||||||
DLM 60-10 |
120 mV |
50 mA |
660 mV |
||||||||
DLM 80-7.5 |
160 mV |
38 mA |
880 mV |
||||||||
DLM 150-4 |
300 mV |
20 mA |
1.65 mV |
||||||||
DLM 300-2 |
600 mV |
10 mA |
3.3 V |
||||||||
Programming Accuracy | |||||||||||
Ethernet (M130/M131) |
|||||||||||
Model |
Voltage (0.1% of VMax) |
Current (0.25% of IMax) |
OVP (0.5% of 1.1 x VMax) |
||||||||
DLM 5-75 |
8 mV |
188 mA |
44 mV |
||||||||
DLM 8-75 |
8 mV |
188 mA |
44 mV |
||||||||
DLM 10-60 |
10 mV |
150 mA |
55 mV |
||||||||
DLM 20-30 |
20 mV |
75 mA |
110 mV |
||||||||
DLM 40-15 |
40 mV |
38 mA |
220 mV |
||||||||
DLM 60-10 |
60 mV |
25 mA |
330 mV |
||||||||
DLM 80-7.5 |
80 mV |
19 mA |
440 mV |
||||||||
DLM 150-4 |
150 mV |
10 mA |
825 mV |
||||||||
DLM 300-2 |
300 mV |
5 mA |
1.65 V |
||||||||
Programming Accuracy | |||||||||||
Ethernet (M130/M131) |
|||||||||||
Model |
Voltage (0.1% of VMax) |
Current (0.25% of IMax) |
OVP (0.5% of 1.1 x VMax) |
||||||||
DLM 5-75 |
8 mV |
188 mA |
44 mV |
||||||||
DLM 8-75 |
8 mV |
188 mA |
44 mV |
||||||||
DLM 10-60 |
10 mV |
150 mA |
55 mV |
||||||||
DLM 20-30 |
20 mV |
75 mA |
110 mV |
||||||||
DLM 40-15 |
40 mV |
38 mA |
220 mV |
||||||||
DLM 60-10 |
60 mV |
25 mA |
330 mV |
||||||||
DLM 80-7.5 |
80 mV |
19 mA |
440 mV |
||||||||
DLM 150-4 |
150 mV |
10 mA |
825 mV |
||||||||
DLM 300-2 |
300 mV |
5 mA |
1.65 V |
||||||||
Programming Accuracy | |||||||||||
GPIB |
|||||||||||
Model |
Voltage (0.1% of VMax) |
Current (0.25% of IMax) |
OVP (0.5% of 1.1 x VMax) |
||||||||
DLM 5-75 |
16 mV |
375 mA |
55 mV |
||||||||
DLM 8-75 |
16 mV |
375 mA |
88 mV |
||||||||
DLM 10-60 |
20 mV |
300 mA |
110 mV |
||||||||
DLM 20-30 |
40 mV |
150 mA |
220 mV |
||||||||
DLM 40-15 |
80 mV |
75 mA |
440 mV |
||||||||
DLM 60-10 |
120 mV |
50 mA |
660 mV |
||||||||
DLM 80-7.5 |
160 mV |
38 mA |
880 mV |
||||||||
DLM 150-4 |
300 mV |
20 mA |
1.65 V |
||||||||
DLM 300-2 |
600 mV |
10 mA |
3.3 V |
||||||||
Display Accuracy | |||||||||||
Model |
Voltage |
Current |
|||||||||
DLM 5-75 |
35 mV |
850 mA |
|||||||||
DLM 8-75 |
50 mV |
850 mA |
|||||||||
DLM 10-60 |
60 mV |
700 mA |
|||||||||
DLM 20-30 |
200 mV |
400 mA |
|||||||||
DLM 40-15 |
300 mV |
160 mA |
|||||||||
DLM 60-10 |
400 mV |
110 mA |
|||||||||
DLM 80-7.5 |
500 mV |
85 mA |
|||||||||
DLM 150-4 |
850 mV |
50 mA |
|||||||||
DLM 300-2 |
2.5 V |
30 mA |
|||||||||
Ripple and Noise | |||||||||||
Model |
Ripple and Noise, Voltage Mode |
OVP Adjustment Range |
|||||||||
Ripple (RMS)* |
Noise (P-P)* |
||||||||||
DLM 5-75 |
5 mV |
30 mV |
0.25 – 5.5 V |
||||||||
DLM 8-75 |
5 mV |
30 mV |
0.4 – 8.8 V |
||||||||
DLM 10-60 |
5 mV |
30 mV |
0.5 – 11 V |
||||||||
DLM 20-30 |
2.5 mV |
15 mV |
1 – 22 V |
||||||||
DLM 40-15 |
2.5 mV |
15 mV |
2 – 44 V |
||||||||
DLM 60-10 |
2.5 mV |
20 mV |
3 – 66 V |
||||||||
DLM 80-7.5 |
4 mV |
20 mV |
4 – 88 V |
||||||||
DLM 150-4 |
7 mV |
40 mV |
7.5 – 165 V |
||||||||
DLM 300-2 |
10 mV |
60 mV |
15 – 330 V |
||||||||
Ripple and Noise: Stability | |||||||||||
Model |
Voltage (0.05% of VMax) |
Current (0.05% of IMax) |
|||||||||
DLM 5-75 |
2.5 mV |
37.5 mA |
|||||||||
DLM 8-75 |
4 mV |
37.5 mA |
|||||||||
DLM 10-60 |
5 mV |
30 mA |
|||||||||
DLM 20-30 |
10 mV |
15 mA |
|||||||||
DLM 40-15 |
20 mV |
7.5 mA |
|||||||||
DLM 60-10 |
30 mV |
5 mA |
|||||||||
DLM 80-7.5 |
40 mV |
3.75 mA |
|||||||||
DLM 150-4 |
75 mV |
2 mA |
|||||||||
DLM 300-2 |
150 mV |
1 mA |
|||||||||
Ripple and Noise | |||||||||||
Model |
Traffic Coefficient |
Maximum Total Remote |
|||||||||
Voltage (0.02% /°C of Vmax) |
Current (0.03% /°C of Imax) |
||||||||||
DLM 5-75 |
1 mV / °C |
22.5 mA / °C |
1 V |
||||||||
DLM 8-75 |
1.6 mV / °C |
22.5 mA / °C |
1 V |
||||||||
DLM 10-60 |
2 mV / °C |
18 mA / °C |
2 V |
||||||||
DLM 20-30 |
4 mV / °C |
9 mA / °C |
2 V |
||||||||
DLM 40-15 |
8 mV / °C |
4.5 mA / °C |
2 V |
||||||||
DLM 60-10 |
12 mV / °C |
3 mA / °C |
2 V |
||||||||
DLM 80-7.5 |
16 mV / °C |
2.25 mA / °C |
2 V |
||||||||
DLM 150-4 |
30 mV / °C |
1.2 mA / °C |
2 V |
||||||||
DLM 300-2 |
60 mV / °C |
0.6 mA / °C |
2 V |