Teseq Profline 2145 Three Phase Harmonics & Flicker System 45kVA

Description

Teseq Profline 2145 Three Phase Harmonics & Flicker System 45kVA is an accurate and flexible three phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-12 and IEC 61000-3-11 on products consuming up to 62 A per phase @ 230 VAC. By adding the optional software and impedance this system can also be used to test to IEC 61000-3-2 and IEC 61000-3-3.

The system is supplied complete with a stable, accurate, programmable 15 kVA per phase power source. The ProfLine 2145 system is therefore ready to measure and record any harmonics & flicker created by the EUT.

Features

  • Complete test system
  • IEC 61000-3-11 and -3-12
  • Option to include -3-2 and -3-3
  • Three phase system up to 62 A per phase
  • Power source suitable for testing to many immunity standards
Download Data Sheet
Print
Email

Specifications

Mains supply options ProfLine 2145-208 ProfLine 2145-400
System contents NSG 1007-45-208 Power source NSG 1007-45-400 Power source
CCN 1000-3 3-phase CCN 1000-3 3-phase
Coupling unit Coupling unit
DAQ card DAQ card
WIN 2100 H&F test software WIN 2100 H&F test software
WIN 2106 PQT test software >16A WIN 2110 PQT test software >16A
WIN 2145 PQT test software WIN 2145 PQT test software
Pre-configured PC Pre-configured PC
USB cable USB cable
Power source (for full specification see separate datasheet)
Power output (AC mode) 3 x 15,000 VA 3 x 15,000 VA
Voltage AC, two ranges 0-150 V and 0-300 V 0-150 V and 0-300 V
Rated current @150 V

(low range)

100 Amps/phase, 240 Amps

peak repetitive

100 Amps/phase, 240 Amps

peak repetitive

Maximum current @120 V

[power graph – see datasheet]

125 Amps/phase, 300 Amps

peak repetitive

125 Amps/phase, 300 Amps

peak repetitive

Maximum current @300 V

(high range)

50 Amps/phase, 120 amps

Peak repetitive

50 Amps/phase, 120 amps

Peak repetitive

Maximum current @230 V

[power graph – see datasheet]

62 Amps/phase, 150 amps

Peak repetitive

62 Amps/phase, 150 amps

Peak repetitive

Frequency range (AC mode) 16 – 819 Hz 16 – 819 Hz
Power output (DC mode) 10,000 watts/phase 10,000 watts/phase
Voltage DC, two ranges 0-200 V and 0-400 V 0-200 V and 0-400 V
Maximum current (low range) 50 Amps 50 Amps
Maximum current (high range) 25 Amps 25 Amps
Supply 3-Phase, 208 Vac L-L, 50/60Hz 3-Phase, 400 Vac L-L, 50/60Hz
Dimensions (per chassis) 1270 x 731x 876 mm 1270 x 731x 876 mm
Weight (per chassis) 522 kg 522 kg
Coupling unit
Number of phases 3 3
Measurement channels 12 12
EUT connector: Rear panel Terminal block Terminal block
Maximum voltage 300 Vac 300 Vac
Maximum current 74 Arms (200 A Pk for 10 ms) 74 Arms (200 A Pk for 10 ms)
Supply power: Voltage 115/230 Vac +/- 10% 115/230 Vac +/- 10%
Supply power: Current <0.5 A <0.5 A
Supply power: Frequency 50/60 Hz 50/60 Hz
Dimensions (HxWxD) 89 x 427 x 560 mm 89 x 427 x 560 mm
Weight 5 kg 5 kg
Stay informed

To keep you in the loop of our latest news, register now for our email newsletter.