EM TEST ACS 503N16 3-Phase AC Voltage Source 16 kVA
Description
EM TEST ACS 503N16 3-Phase AC Voltage Source 16 kVA is designed for harmonics and flicker testing. It meets the corresponding specifications as per IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 as well as per IEC/EN 61000-3-11 and IEC/EN 61000-3-12 for measuring DUTs having a nominal current of more than 16A per phase.
As per standard requirements a pure AC voltage is needed for measurements of harmonics and flicker. The output voltage of the ACS 503N16 is guaranteed to be sinusoidal with a very low distortion (THD) of less than 0.1% regardless of the load.
The ACS 503N16 AC voltage source is electronically protected against overtemperature, overcurrent, overvoltage and undervoltage.
MODEL SERIES OVERVIEW
ACS 503N-series – 3-Phase AC Voltage Sources, 16 kVA up to 90 kVA
Features
- Frequency (fund.) 40Hz .. 80Hz
- Very low distortion (THD)
- Very high voltage stability
- Output power 16kVA .. 90kVA (depending on model)
- Output voltage max. 300V(p-n)
- Inrush current capability
- Remote control by the DPA 503N via RS232
Specifications
Output Power | 16,000VA |
Output current,
50Hz (60Hz) |
Inductive load: 23A (24A)
Resistive load: 18A (16A) Capacitive load: 14A (12A) max. 60A (61A) RMS for 3 sec. Repetitive peak: 300A |
Input current | Max. 72 |
Fuse | 3 x 63A |
Weight | 400kg |
Size | 1670mm x 920mm x 625mm |