EM TEST NetWave 7 Single Phase AC/DC Power Source

Description

EM TEST NetWave 7 Single Phase AC/DC Power Source is designed to meet the requirements as per the standards IEC/EN 61000-4-13, IEC/EN 61000-4-14 and IEC/EN 61000-4-28. Used as a DC power source it covers the requirements as per the standards IEC/EN 61000-4-17 (Ripple on DC) and IEC/EN 61000-4-29 for voltage dips and interruptions on DC supplies.

With its low distortion and high stability, even if supplying dynamic loads, the NetWave 7 guarantees full compliant measurements for harmonics and flicker testing as per IEC/EN 61000-3-2, -3-3, -3-11 and -3-12 as well as JIS C 61000-3-2.

The NetWave 7 is well suited for testing inverters (e.g. solar power, wind power) and e-vehicles. Additionally, it offers the necessary capabilities for avionics testing as per RTCA/DO-160, AIRBUS ABD0100 and BOEING as well as per MIL-STD-704.

 

MODEL SERIES OVERVIEW

NetWave Series (1-Phase) Programmable Multifunctional AC/DC Power Sources

Features

  • Wide Power Bandwidth; DC – 5kHz
  • Output Power up to 7,500 VA AC and 9,000 W DC
  • Output Voltage max. 360V AC and +/- 500V DC
  • High Inrush Current Capability up to 200A
  • Extended trigger and control capabilities (NetWave 7.3)
  • Built-in Arbitrary Waveform Generator for easy generation of complex waveforms
  • Standard Test Routines for IEC/EN requirements as well as for Aircraft and MIL-STD testing
  • Built-in voltage and current measurement (option)
Download Data Sheet
Print
Email

Specifications

TECHNICAL DETAILS
Output Voltage 0 V – 300 VAC (RMS)

0V – +/-425 VDC

Output Current 26 A (RMS) continuous

47 A (RMS) short-term (max. 3 s)

200 A repetitive peak

SPECIFICATIONS
Output frequency Output frequency DC – 5,000Hz
Frequency accuracy, stability 100ppm
DC offset with AC signal <20mV with linear load
Slew rate 8V/us
REGULATION
Voltage sense Internal or external, 4 wires
Distortion (THD) Less than 0.5%, @50/60Hz
Output voltage stability Better than 0.1%
Output voltage accuracy Better than 0.5%
Max. compensable drop on wire 5% f.s.
Current limiter 2A to Imax for f < 75Hz (NetWave 3)

5A to Imax for f < 75Hz (NetWave 7.x)

Protection Over current, over voltage,

over temperature, low voltage

OUTPUTS
DUT connection 4mm safety lab connectors

DUT adapter with connector

(depends on country of use)

DISPLAY AND CONTROLS
Display 2-Line LCD, 40 characters
LED indicators Power On

Active output channel

Trigger

Functional status hard disk

Operation 6 function keys,

Test On key: ON/OFF key for the

power source

INTERFACES GPIB, Ethernet

USB (for memory stick)

RS 232 (input from DPA analyzer)

Frame bus (internal system bus)

Stay informed