Sorensen SGA Series Modular Programmable DC Power Supply 5kW – 30kW
Description
Sorensen SGA Series 5kW-30kW modular programmable DC Power Supply 5kW – 30kW represents the next generation of high power programmable DC power supplies. The SG Series is designed for exceptional load transient response, low noise and the highest power density in the industry. With a full 15 kW available down to 20Vdc output, and 12kW at 10Vdc and 1200ADC in a 3U package, the SG leads the industry in power density. The SG provides models up to 1000Vdc at 15amps. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.
At the heart of the SG series is a 5 kW power module. Depending on the output voltage, one to six modules can be configured in a single chassis to deliver 5 kW to 30 kW of power. Combinations of these chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system current. Available in two control versions, the SGA has basic analog controls, while the SGI provides intelligent control features.
(Sorensen General purpose Analog) The SGA, with its industry leading price performance, is available for customers requiring simple front panel analog controls or external control. With the same high performance power electronics as the SGI, the SGA provides essential features like 10- turn potentiometers for setting voltage and current, 3 ½ digits LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.
Features
- High Power Density: up to 15 kW in 3U, 30 kW in a 6U chassis
- Wide Voltage Range: 0-10V up to 0-1000V, from 4 to 30 kW
- Fast Load Transient Response: Protection from undesired voltage excursions
- Low Ripple and Noise
- Hardware Trigger (Ethernet Option)
- Parallelable up to 150 kW
- Sequencing: Free system controller & speed up test
- Low audible noise: Temperature controlled variable speed fans
Sorensen SGA Applications
- Burn-In
- Materials Research
- Product Validation
- Rackmount ATE Systems
- Compliance Testing
- Process Control
- Automotive Electronics
- Battery Charging
Specifications
SGI / SGA Comparison Chart | ||
Feature |
SGA |
SGI |
Modular Design |
• |
• |
Fast Load Transient |
• |
• |
Parallelable |
• |
• |
Analog & Digital Summing |
Optional |
• |
Direct Front Panel V/1 Control |
• |
• |
3½ Digit LED Readout |
• |
|
Graphics Display |
• |
|
Sequencing |
• |
|
Save / Recall Setups |
• |
|
System Power Readouts |
• |
|
Constant Power Mode |
• |
|
IEEE-488.2/RS-232C |
Optional |
RS-232C Std |
LXI Class C Ethernet/ RS-232 |
Optional |
RS-232C Std, Ethernet Optional |
Front Panel Dust Filter |
Optional (3U unit only) |
Optional (3U unit only) |
Common | |||||||||
Remote Sense | Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply). | ||||||||
Parallel Operation | Up to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory. | ||||||||
Series Operation | Up to 2 units (see Output Float Voltage) | ||||||||
Input | |||||||||
Nominal Voltage 3 phase, 3 wire + ground |
208/220 VAC (operating range 187 – 242 VAC) 380/400 VAC (operating range 342 – 440 VAC) 440/480 VAC (operating range 396 – 528 VAC) |
||||||||
Frequency | 47 – 63Hz , 400Hz ( 400Hz @ 208VAC, for 6U units is optional modification and does not carry CE, UL or CSA markings ) | ||||||||
Power Factor | >0.9 typical for 10V – 30V, 50V, 1000V and other models with optional “PF” modification. >0.75 typical for 208/220 VAC input (40V, 60V – 800V models, 0.9 available with modification “PF”) >0.72 typical for 380/480 VAC input (40V, 60V – 800V models, 0.9 available with modification “PF”) >0.69 typical for 440/480 VAC input (40V, 60V – 800V models, 0.9 available with modification “PF”) |
||||||||
Protection | ½ cycle ride-though , typical, on all three phases, 3 cycle ride through on single phase; missing phase shutdown ( 800V model 6.4 msec on all 3 phases ) | ||||||||
SORENSEN SG Series |
|||||||||
Power
Unit Weight: |
5kW 52 lbs. |
10kW 66 lbs. |
15kW 80 lbs. |
20kW 132 lbs. |
25kW 146 lbs. |
30kW 160 lbs. |
|||
Shipping Weight |
62 lbs |
76 lbs. |
115 lbs. |
167 lbs. |
181 lbs. |
195 lbs. |
|||
Dimensions: L/W/H |
26.4″ x 19″ x 5.25″ |
26.4″ x 19″ x 5.25″ |
26.4″ x 19 x 5.25″ |
25″ x 19″ x 10.5″ |
25″ x 19″ x 10.5″ |
25″ x 19″ x 10.5″ |
|||
(40V and above) |
|||||||||
Voltage-Current Combinations:
(rounded to whole A) |
40X125 |
40X250 |
40X375 |
** |
** |
** |
|||
50X100 |
50X200 |
50X300 |
** |
** |
** |
||||
60X83* |
60X167* |
60X250* |
60-333* |
60-417* |
60-500* |
||||
80X63 |
80X125 |
80X188 |
80-250 |
80-313 |
80-375 |
||||
100X50* |
100X100* |
100X150* |
100-200* |
100-250* |
100-300* |
||||
160X31* |
160X63* |
160X94* |
160-125* |
160-156* |
160-188* |
||||
200X25 |
200X50 |
200X75 |
200-100 |
200-125 |
200-150 |
||||
250X20 |
250X40 |
250X60 |
250-80 |
250-100 |
250-120 |
||||
330X15 |
330X30 |
330X45 |
330-61 |
330-76 |
330-91 |
||||
400X12 |
400X25 |
400X38 |
400-50 |
400-63 |
400-75 |
||||
600X8 |
600X17 |
600X25 |
600-33 |
600-42 |
600-50 |
||||
800X6 |
800X13 |
800X19 |
** |
** |
** |
||||
SORENSEN SG Series |
|||||||||
Power
Unit Weight: |
4kW 65 lbs. |
5kW 65 lbs. |
8kW 85 lbs. |
10kW 85 lbs. |
12kW 110 lbs. |
15kW 110 lbs. |
|||
Shipping Weight |
85 lbs |
85 lbs |
105 lbs. |
105 lbs. |
130 lbs. |
130 lbs. |
|||
Dimensions: L/W/H |
26.5″ x 19″ x 5.25″ |
26.5″ x 19″ x 5.25″ |
26.5″ x 19″ x 5.25″ |
26.5″ x 19″ x 5.25″ |
26.5″ x 19″ x 5.25″ |
26.5″ x 19″ x 5.25″ |
|||
(30V and below) |
|||||||||
Voltage-Current Combinations: |
10X400 |
10X800 |
10X1k2 (1200) |
||||||
15X267 |
15X534 |
15X801 |
|||||||
20X250 |
20X500 |
20X750 |
|||||||
30X167 |
30X334 |
30X501 |
|||||||
Environmental | |||||||||
Operating Temperature | 0 to 50º C | ||||||||
Storage Temperature | -25º C to 65º C | ||||||||
Humidity Range | Relative humidity up to 95% non-condensing, 0º C – 50º C | ||||||||
Altitude | Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m) | ||||||||
Cooling | Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing. | ||||||||
Regulatory | Certified to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, Semi-F47 Compliant. LVD Categories: Installation Category II: Pollution Degree 2; Class II Equipment: for Indoor Use Only, back panel not user accessible (see user manual for installation instructions) EMC Directive, EN 61326:1998 |
||||||||
Front Panel Dust Filter | 30 PPI (Pores Per Inch) – must ensure adequate airflow and / or derate max. temperature. 3U unit only. |
||||||||
Output | |||||||||
Ripple & Noise (Voltage Mode, Typical) | See Output: Voltage & Current Ranges Chart above. Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1μf at load | ||||||||
Ripple (Current Mode) | <+/- 0.04% of full scale rms current | ||||||||
DC Voltage Slew Rate (40-800V) | ≈< 100 ms 5-95% of full scale typical – resistive load (Contact factory for model specific slew rates) | ||||||||
Output Voltage Rise Time (10-30V) |
Rise Time, ms, MAX |
Condition |
|||||||
10 |
Measured from 10% to 90% of the output voltage change – resistive load, typical |
||||||||
Output Voltage Fall Time (10-30V) |
Fall Time, MS MAX |
Condition |
|||||||
No Load 1 |
100% CC Load 10 |
100% CR Load 10 |
Measured from 90% to 10% of the output voltage change. – resistive load, typical |
||||||
Output Current Rise Time (10-30V) |
Rise Time, ms, MAX |
Condition |
|||||||
20 |
Measured from 10% to 90% of the output current change – resistive load, typical |
||||||||
Output Current Fall Time (10-30V) |
Rise Time, ms, MAX |
Condition |
|||||||
10 |
Measured from 90% to 10% of the output current change – resistive load, typical |
||||||||
DC Current Slew Rate | 45A / ms typical – resistive load | ||||||||
Line Regulation (with sense wires used) | (±10% of nominal AC input, constant load) Voltage Mode: +/- 0.01% of full scale (40-800V) Current Mode: +/- 0.05% of full scale (40-800V) Voltage Mode and Current Mode: +/- 0.05% of full scale (10-30V) |
||||||||
Load Regulation (with sense wires used) | (no load to full load, nominal AC input) Voltage Mode: +/- 0.02% of full scale (40-800V) Current Mode: +/- 0.1% of full scale Voltage Mode: +/- 0.05% of full scale (10-30V) |
||||||||
Load Transient Response | Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change | ||||||||
Efficiency | 87% typical at nominal line and max load | ||||||||
Stability | ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature, typical | ||||||||
Temperature Coefficient | 0.02%/ C of maximum output voltage rating for voltage set point, typical 0.03%/ C of maximum output current rating for current set point, typical |
||||||||
Output Float Voltage | Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/current, in not system current is limited to lower of the two supplies. |