EM TEST NetWave 20.3 (3-Phase) AC/DC Power Source
Description
EM TEST NetWave 20.3 (3-Phase) AC/DC Power Source is designed to fully meet the requirements as per IEC/EN standards 61000-4-13, 61000-4-14, 61000-4-28 and pre-compliance testing to 61000-4-27. It is also used as a DC power source to cover the requirements as per the standards IEC/EN 61000-4-17 (Ripple on DC) and IEC/EN 61000-4-29 for voltage dips and interruptions on DC supplies. The NetWave series is well suited for testing inverters (e.g. solar power, wind power) and e-vehicles like LV 123 standard.
Additionally, the NetWave series (3-phase) offers the necessary capabilities for avionics testing as per DO-160, Airbus ABD0100 and Boeing as well as per MIL-STD-704 and is perfectly suited as reference source for Harmonics and Flicker testing.
MODEL SERIES OVERVIEW
NetWave Series (3-Phase) Three-Phase Multifunctional AC/DC Power Sources
Features
- Wide Power Bandwidth; DC – 5 kHz
- Output Power up to 270 kVA AC / 324 kW DC
- Output up to 3*690 VAC (p-p), +/-1120 VDC
- High Inrush Current Capability
- Power-recovery up to nominal power (optional)
- Built-in Arbitrary Waveform Generator
- Standard Test Routines for IEC/EN requirements as well as for Aircraft and MIL-STD testing
- Multiple Interfaces
Specifications
NETWAVE 20.3 | |
Output voltage | 0 V – 3*400 V AC (p-n)
0 V – 3*690 V AC (p-p) 0 V – +/- 1120 V DC |
Output current (@ max. 300 V AC/360 V DC) | 26 A (RMS) continuous
47 A (RMS) short-term (max. 3 s) 200 A repetitive peak |
Power Recovery 20 | Included |
GENERAL DATA (ALL MODELS) | |
SPECIFICATIONS | |
Output frequency | DC – 5,000 Hz |
Frequency accuracy | 100 ppm |
Output connectors | Safety lab connectors
CEE type 32 A (only for NetWave 20.x and NetWave 30.x) |
Interfaces | GPIB
Ethernet RS 232 (input from DPA analyser) Frame bus (internal system bus) |
Phase accuracy | Resolution 1° |
Output noise | < 50 V: 110 mV rms
> 50 V: 320 mV rms |
Slew Rate | 8V/μs |
REGULATION | |
Voltage sense | Internal or external, 4 wires |
Distortion (THD) | Less than 0. 5%, @50/60 Hz |
Output voltage Stability | Better than 0.1 % |
Output voltage Accuracy | Better than 0.5 % |
Max. compensable drop on wires | 5 % of V nominal |
Current limiter | 5 A to Imax
Stop / Continuous (behavior) |
Protection | Over current
Over voltage Over temperature Low voltage |
TRIGGER AND DUT MONITORING | |
Trigger | 2 inputs, 2 outputs |
DUT monitors | 2 inputs, configurable |
OPTION FOR DC EXTENDED VOLTAGE RANGE | |
* with option | OPT-3 DC-EVR,
Double the DC voltage |
- Basic Standards
- IEC 61000-3-11
- IEC 61000-3-12
- IEC 61000-3-2
- IEC 61000-3-3
- IEC 61000-4-11
- IEC 61000-4-13
- IEC 61000-4-14
- IEC 61000-4-17
- IEC 61000-4-27
- IEC 61000-4-28
- IEC 61000-4-29
- IEC 61000-4-34
- MIL-STD
- RTCA DO-160 Section 16
- RTCA DO-160 Section 18
- MIL-STD 461
- MIL-STD-704
- RTCA DO-160
- AIRBUS
- BOEING
- Automotive OEM Specifications
- PSA B21 7110
- Mercedes-Benz MBN LV 123
- BMW GS 95023
- Volkswagen VW 80300
- Volkswagen VW 80303
- International Standards
- JIS C 61000-3-2