EM TEST RCB 200N1 Transient Immunity Test Generator
Description
RCB 200N1 Transient Immunity Test Generator meeting Ford FMC1278 and EMC-CS-2009.1
EM TEST RCB 200N1 Transient Immunity Test Generator is built to generate pulses such as CI 220 A1, A2-1, A2-2, C-1 and C-2, CI 260 F and RI 130 A2-1 and A2-2 for which the RCB 200N1 is built into a metal housing. For RI 130 testing the RCB 200N1 offers BNC-type coaxial outputs to connect the specified test fixture needed for this test.
Features
- Approved by Ford acc. to FMC1278 and EMC-CS-2009.1 requirements
- Pulses CI 220: A1, A2-1, A2-2, C-1 and C-2
- Pulse CI 260: F
- Pulses RI 130: A2-1, A2-2 using a coupling test fixture
- Fixed repetition times and pseudo-random timing
- Automatic control of mode and switch settings by micro-controller
- Easy control by manual operation
- EOL status control of the relay as per FORD requirement
- Internal/external trigger mode operation
Download Data Sheet
Print
Email
Specifications
TECHNICAL DATA | |
RCB 200N1 | Circuitry as per Annex F, Figure F-1 with the following components: |
Resistor R1 | 51 ohms, 25W |
Resistor R2 | 220 ohms ± 5%, 2W |
Resistor R3 | 33 ohms ± 5%, 10W |
Resistor R4 | 6 ohms ± 5%, 50W |
Capacitor C1 | 100 nF capacitor, 400V |
Inductor L1 | 5 uH inductor (Osborne transformer part no. 8745) |
Inductor L2 | 100 mH inductor (Osborne transformer part no. 32416) |
Diode D1 | Zener diode, 39V, 5W |
Transistor Q1 | NPN transistor |
SW0 – SW4 | Single Throw Switch |
RLY1 | 12-volt AC relay, NC contact used Potter & Brumfield KUP-14A15-12) |
OPERATION | |
TEST ON | Activates the DUT supply for CI 220 and CI 260 test pulses; no function for RI 130 as this is performed without DC voltage |
ID | To select the test |
Pulse | To select the pulses of the preset test |
Mode | To select the mode of generating the pulses |
Start/Stop | To start/stop the test |
INPUTS/OUTPUTS | |
Input | 4mm safety lab connectors for DC supply (e.g. battery or VDS 200x) |
Trigger | External trigger input (BNC) |
Outputs | 4mm safety lab connectors for CI 220 and CI 260 testing; 50-ohm BNC connectors for RI 130 testing |
LEDs | Indicates:
– TEST ON status – Test (ID) – Pulse – Mode – Sequence or endless – Switching status (SW0 – SW4) – Relay EOL (end of life reached) |
GENERAL DATA | |
Dimensions
Weight |
330mm x 230mm x 115mm
Approx. 7.5kg |
Fuse | 20A for DUT supply current |
Protection | Electronically protected against overvoltage and reversed polarity |