EM TEST CWS 500N1.3 Continuous Wave Simulator
Description
CWS 500N1.3 Single Box Solution for RF Conducted Immunity Testing – 80W
EM TEST CWS 500N1.3 Continuous Wave Simulator is designed for testing conducted RF immunity per IEC/EN 61000-4-6 and related standards with a frequency range of 10 kHz to 400 MHz. Equipped with a 1 GHz current monitor the CWS 500N1.3 can be used up to 1 GHz by means of an external amplifier.
The CWS 500N1.3 delivers signals up to 400 MHz for the internal amplifier while the frequency range can be extended from 9 kHz to 1 GHz using an external amplifier. The built-in class A amplifier allows to test up to 30V using any coupling/decoupling device (CDNs, EM clamps, current injection clamps).
The built-in 1 GHz current monitor offers the ability to control the injected current signal while using injection clamps.
MODEL OVERVIEW
CWS 500N1.4 Simulator for RF Conducted Immunity Testing 100 kHz – 300 MHz
Features
- Test procedure acc. IEC 61000-4-6 Ed. 4
- Built-in amplifier saturation and linearity check
- Built-in amplifier, 10 kHz to 400 MHz
- Built-in power meter, 9 kHz to 1 GHz
- Built-in dual directional coupler
- Automatic calibration via built-in power meter
- Connection for external amplifiers up to 1 GHz
- USB-Interface
Specifications
TECHNICAL DETAILS | |
OUTPUT | |
Output level | 1 V – max. 30 V (emf)
All standard test levels are guaranteed with all coupling methods |
Output power | 80 W (49 dBm) at 1dB compression |
Output impedance | 50 ohm |
Harmonic distortion | < -20 dBc at max. power |
Amplifier gain | 48 dB |
Output impedance | 50 ohm |
OUTPUT | |
Direct RF output | N connector (on the front panel) |
SIGNAL GENERATOR | |
Output level | -63.5 dBm to 0 dBm |
Frequency range | 9 kHz to 1 GHz |
Output impedance | 50 ohm |
Direct RF output | To control an external amplifier |
DUAL DIRECTIONAL COUPLER | |
Frequency range | 10 kHz to 1 GHz |
Power | 150 W max. |
Insertion loss | 0.6 dB max. |
Mainline VSWR | 1.1:1 max. |
GENERAL DATA | |
INTERFACE | |
Serial interface | USB |
Parallel interface | IEEE 488, addresses 1 to 30 |
Fail 1 | BNC input; test will be stopped when active low |
Fail 2 | BNC input; test status will be saved (max. 10 events) when active low.
Test will continue. |
GENERAL DATA | |
Dimensions, weight | 19″/3 HU, approx. 17 kg |
Supply voltage | 115 V to 230 V +10/-15 %, 50/60 Hz |
Input power | Max. 380 W |
- Basic Standards
- IEC 61000-4-6
- Telecom Standards
- Telcordia GR-1089
- Product Standards
- EN 300 386 V1.3.2
- EN 55024
- IEC 60601-1-2
- IEC 61326-1
- IEC 61850-3
- EN 300 329
- EN 300 340
- EN 300 342-1
- EN 301 489-1
- EN 301 489-24
- EN 301 489-7
- Automotive Standards
- ISO 11452-4
- Generic Standards
- EN 61000-6-1
- EN 61000-6-2
- Automotive OEM Specifications
- BMW GS 95002
- DaimlerChrysler DC-10614
- DaimlerChrysler DC-11224
- Ford EMC-CS-2009.1
- GMW3097
- Namur NE 21