EM TEST OCS 500N6F.2 Oscillatory Wave Simulator

Description

EM TEST OCS 500N6F.2 Simulator for Fast and Slow Damped Oscillatory Waves and Ringwave

EM TEST OCS 500N6F.2 includes test capabilities for fast damped oscillatory waves at 3 MHz, 10 MHz and 30 MHz up to 4.4kV and is extendable for slow damped oscillatory waves at 100 kHz / 1 MHz up to 3.0 kV as per IEC/EN 61000-4-18 and for ringwave up to 6 kV as per IEC/EN 61000-4-12.

The OCS 500N6F.2 comes with a built-in coupling/decoupling network for either single phase or three-phase and is rated for currents of 16 A or 32 A per line.

 

MODEL SERIES OVERVIEW

OCS 500N6F-series Compact Simulators for Fast/Slow Damped Oscillatory Waves and Ringwave

Features

  • Fully automated single box test system
  • Single DUT port
  • Fast Damped Oscillatory Waves up to 4.4 kV
  • Slow Damped Oscillatory Waves up to 3 kV (option)
  • Ringwave up to 6 kV (option)
  • Built-in CDN, 1-phase or 3-phase up to 32 A
  • Front panel operation
  • USB and GPIB interfaces
Download Data Sheet
Print
Email

Specifications

MODEL OVERVIEW
OCS 500N6F.2 AC 3×440 V / 16 A, DC 250 V / 16 A
FAST DAMPED OSCILLATORY MODULE
FAST DAMPED OSCILLATORY WAVES AS PER IEC/EN 61000-4-18
Voltage (o.c.) at HV output 450 V – 4,400 V ±10%
Rise time 5 ns ±30%
Oscillation frequencies 3 MHz, 10 MHz and 30 MHz, ±10%
Decaying Peak 5 to be > 50% of peak 1 value

Peak 10 to be < 50% of peak 1 value

Source impedance 50 ohms ±20%
Coupling common mode
Polarity Positive, negative
Repetition rate Max. 5,000 /s ±10%
Burst duration 50 ms ±20%, at 3 MHz

15 ms ±20%, at 10 MHz

5 ms ±20%, at 30 MHz

Burst period 300 ms ±20%
Short-circuit current 9 A – 88 A ±20%
Rise time current waveform < 330 ns at 3 MHz

< 100 ns at 10 MHz

< 33 ns at 30 MHz

Decaying (current) Peak 5 to be > 25% of peak 1 value

Peak 10 to be < 25% of peak 1 value

GENERAL SPECIFICATIONS
OUTPUT
Direct Via HV-safety lab connectors
Coupling mode Line to line Line(s) to ground (PE)
DUT supply
OCS 500N6F.2 AC: 3×440 V / 16 A; 50/60 Hz

DC: 250 V / 16 A

CRO trigger 5V trigger signal for oscilloscope
MEASUREMENTS
Ring wave Peak voltage and peak current in LCD
GENERAL DATA
INTERFACE
Optical interface Opto link, 3 m cable USB A connector
Parallel interface IEEE 488, addresses 1 – 30
GENERAL DATA
Dimensions, weight 19″ / 9 HU, approx. 50 kg
Supply voltage 115/230 V +10/-15%
Fuses 2 x T2AT (230V); 2 x T4AT (115V)