California Instruments 15003iX AC Power Source 15kVA

Description

The iX Series II represents a new generation of AC and DC power source that addresses increasing demands on test equipment to perform more functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the iX Series II systems are capable of handling complex applications that have traditionally required multiple instruments.

The sleek integrated approach of the iX Series II avoids the cable clutter that is commonly found in AC test systems. The i/iX Series II is rack mountable with a 4U chassis design. All connections are made internally and the need for external digital multimeters, power harmonics analyzer and current shunts or clamps is completely eliminated. Using a state of the art digital signal processor in conjunction with precision high resolution A/D converters, the iX Series II provides more accuracy and resolution than can be found in some dedicated harmonic power analyzers. Since many components in the iX Series II are shared between the AC/DC source and the power analyzer, the total cost of the integrated system is less than the typical cost of a multiple unit system.

For less demanding applications, the Compact iX Series provides similar output and transient capabilities as the iX Series II, as well as basic measurements.

Features

  • 3000 VA to 15000 VA of AC Output Power
  • Combines AC/DC source and power analyzer
  • Harmonic analysis of Voltage and Current
  • Programmable Impedance
  • AC, DC and AC+DC Output Modes
  • Multiple Chassis Configurations
  • Powerful output transient generation
  • High Crest Factor Capability
  • Arbitrary waveform generation
  • IEC 61000-3-2 and IEC 61000-3-3
Download Data Sheet
Print
Email

Specifications

Operating Modes
Model

iX Series II

i Series II

Modes

AC, DC or AC+DC

AC or DC

AC Output Mode
Frequency Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz; See V-F rating chart. below)
Total Power 3001i/iX: 3000 VA, 5001i/iX: 5000 VA, 9003i/iX: 3000 VA 3ø, with mode iX: 9000 VA 1ø, 10001i/iX: 10000 VA, 15001i/iX: 15000
VA, 15003i/iX: 5000 VA/ø 3ø, with mode iX: 15000 VA/ø 1ø
Load Power Factor 0 to unity at full output VA
AC Voltage Mode
Voltage Ranges

 

 

 

 

 

 

 

 

 

 

Output Noise
(20 kHz to 1 MHz)

Range

VLow

VHigh

AC

0-150 V

0-300 V

AC+DC

0-150 V

0-300 V

Load Regulation
(with ALC on)

< 0.2%

Load Regulation
(with ALC off)

< 0.5% DC to 100 Hz,
< 0.6% 100 Hz to 500 Hz in high voltage range,
< 2.2% 100 Hz to 500 Hz in low voltage range,
< 3% 500 Hz to 1000 Hz

Line Regulation

< 0.1% for 10% line change

< 250 mVrms typ., < 500 mVrms max.
Harmonic Distortion (Linear) < 1% from 16 – 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load)
DC Offset < 20 mV External Amplitude Modulation: Depth: 0 – 10 %, Frequency: DC – 2 KHz
Isolation Voltage 300 Vrms output to chassis
AC Mode Current
Model

Model

3001 i/iX

5001 i/iX

9003 i/iX 3ø

Steady State AC Current

300 V range

11.1

18.5

11.1 /ø

 

150 V range

22.2

37.0

22.2 /ø

Note: Constant power mode provides increased current at reduced voltage (See chart below)
Model

Model

10001 i/iX

15001 i/iX

15003 i/iX 3ø

Steady State AC Current

300 V range

37.0

55.5

18.5 /ø

 

150 V range

74.0

111.0

37.0 /ø

Note: Constant power mode provides increased current at reduced voltage (See chart below)
Model

Model

3001 i/iX

5001 i/iX

9003 i/iX 3ø

Peak Repetitive AC Current

High range

96.0

96.0

96.0 /ø

 

Low range

110.0

110.0

110.0 /ø

Model

Model

10001 i/iX

15001 i/iX

15003 i/iX 3ø

Peak Repetitive AC Current

High range

192.0

288.0

96.0 /ø

 

Low range

220.0

330.0

110.0 /ø

Programming Accuracy Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed value, Phase: < 1.5° with balanced load at 50/60 Hz
Programming Resolution Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 – 81.91 Hz, 0.1 Hz from 82.0 – 819.1 Hz, 1 Hz from 820-1000 Hz, Current Limit: 0.1 A, Phase, 0.1°
Output Relay Push-button controlled or bus controlled output relay
Output Impedance (iX Only) Programmable Z on 3001iX, 5001iX, 9003iX and 15003iX (3ø mode only) for 50 Hz fundamental
Resistive Range: 17 – 1000 mOhm,resolution: 4 mOhm accuracy, 2 % FS
Inductive Range: 230 – 1000 μH, resolution: 4 μH, accuracy: 2 % FS
Measurements – Standard (AC Measurements)
Parameter

Frequency

RMS Voltage

RMS Current

Peak Current

Range

16-500 Hz

0-300 V

0-40 A

0-120 A

Accuracy* (±)
0.01% +
0.01 Hz

< 100 Hz

100 – 500 Hz

0.5 V + 0.02%

0.1 V + 0.02%

0.5 A + 0.02%

0.1 A + 0.02%

0.5 A + 0.02%

0.1 A + 0.02%

Resolution*

0.01 Hz

10 mV

1 mA

1 mA

Parameter

Crest Factor

Real Power

Apparent Pwr

Pwr Factor

Range

0.00-6.00

0-6 kW

0-6 kVA

0.00-1.00

Accuracy* (±)
0.01% +
0.01 Hz

0.05

0.05

10 W + 0.1%

20 W + 0.1%

10 VA + 0.1%

20 VA + 0.1%

0.01

0.02

Resolution*

0.01

1 W

1 VA

0.01

Parameter

DC Voltage

DC Current

Power

Voltage Ranges

0-300 V

0-40 A

0-6 kW

Accuracy* (±)
0.01% +
0.01 Hz

150 mV

150 mV

70 mA

70 mA

15 W

15 W

Resolution*

10 mV

1 mA

1 W

* Measurement system bandwidth = DC to 48 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy specifications are times two for 10001i/iX /30003i/iX and times three for 15001i/iX and 9003i/iX and 15003i/iX with MODE-iX option when in single phase mode. For 10001i/iX, 15001i/iX and 30003i/ iX, resolution decreases by factor of 10, ranges for current and power increases by factor of three. PF accuracy applies for PF > 0.5 and VA > 50% of range.
Measurements – Harmonics
Parameter

Frequency Fundamental Harmonics

Phase

Voltage

Current

Range

16.00-500.0 Hz / 32.00 Hz – 48.00 kHz

0.0 – 360.0°

Fundamental Harmonics 2 – 50

Fundamental Harmonics 2 – 50

Accuracy* (±)

0.01% + 0.01 Hz

2° typ.

250 mV 0.1% + 250 mV+0.1% /1 kHz

50 mA/0.1% + 50 mA +0.1% /1 kHz

Resolution

0.01 Hz

0.5°

10 mV / 10 mV

10 mA / 10 mA

* Accuracy specifications are valid above 100 counts. Accuracy specifications are times three for three phase mode. Harmonics frequency range in three phase mode is 32 Hz – 16 kHz. Resolution decreases by factor of 10 for 9003iX and 15003iX with Mode-iX option in 1 phase mode and for 10001iX, 15001iX and 30003i/iX.
DC Mode Output
Power (Max at full scale of DC Voltage Range) 3001i/iX: 2100 W, 5001i/iX: 3500 W, 9003i/iX: 2100 W/ø 3ø, 6300 W/ø 1ø, 10001i/iX: 7000 W, 15001i/iX: 10500 W, 15003i/iX: 3500 W/ø 3ø, 10500 W/ø 1ø
Voltage Ranges Range: Low: 200 Vdc, High: 400 Vdc
Line Regulation < 0.1% FS or 10% line change
Output Noise < 250 mV rms typ., < 500 mV rms max., (20 kHz to 1 MHz)
Max DC Current (Maximum current at 65% of V Range)
Model

3001 i/iX

5001 i/iX

9003 i/iX

9003 i/iX 3ø

400V range

7.8

13

23.4

7.8

200V range

15.6

26

46.8

15.6

Model

10001 i/iX

15001 i/iX

15003 i/iX 3ø

400V range

26

39

13

200V range

52

78

26

Current Limit Programmable from 0 A to maximum current for selected range
AC+DC Mode Output
Output Power (iX only) Full AC Power if DC component is less than 20% of full scale voltage, Full DC power if DC component is above 20%
Storage
Non Volatile Mem. storage 16 instrument setups, 200 user defined waveforms
Waveforms
Waveform Types i Series II: Sine, iX Series II: Sine, Square, Clipped sine, User defined
User defined waveform storage Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200 (One group can be active at a time)
System Interface
Inputs Remote shutdown, External Sync, Clock/Lock (option)
Outputs Function Strobe, Clock/Lock (option)
Protection
Over Load Constant Current or Constant Voltage mode
Over Temperature Automatic shutdown
Remote Control
IEEE-488 Interface IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax
RS232C Interface 9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2 SCPI Syntax (Supplied with RS232C cable)
DC Mode Output
Voltage 3001 and 9003: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10% Vac, (L-L, 3ø) (Input range must be specified when ordering)
Max DC Current (Maximum current at 65% of V Range)
Model

3001i/iX

5001i/iX

9003i/iX

187-264V

25 A

23 A

75 A

360-528V

N/A

12 A

N/A

Model

10001 i/iX

15001 i/iX

15003 i/iX 3ø

187-264V

46 A

69 A

69 A

360-528V

24 A

36 A

36 A

Inrush Current per chassis < 100 Apk for 100 μs at 208-240 V, < 50 Apk for 100 μs at 400-480 V
Line Frequency 50-60 Hz ± 10 %
Efficiency 75% typical
Power Factor 0.6 typical
AC Service
Regulatory IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
RFI Suppression CISPR 11, Group1 , Class A
Rear Panel Connectors AC Input & Output terminal block with cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, Remote voltage sense terminal block, System Interface Connector, *RS232 DB9 to DB9 cable supplied
Physical Dimensions
Dimensions Height: 7” (178 mm), Width: 19” (483 mm), Depth: 24” (610 mm)
(depth includes rear panel connectors)
Weight per 5001i/iX Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg
Vibration and Shock Designed to meet NSTA project 1A transportation levels
Air Intake/Exhaust Forced air cooling, side air intake, rear exhaust.
Operating Humidity 0 to 95 % RAH, non condensing.
Temperature Operating: 0 to 40° C, Storage: -20 to +85° C
Stay informed