California Instruments 1251P AC Power Source 1250 VA

Description

Compact AC Power with European and US outlet sockets to connect the load, the 801P, 1001P and 1251P portable programmable AC power sources are ideal for a wide variety of applications.

Universal input allows use anywhere in the world to provide a convenient source of variable utility power for the testing and evaluation of domestic and commercial equipment. All common line voltage and frequency combinations are covered.

In addition, the frequency range covers 500 Hz, making these products ideal for commercial and defense avionics applications. The current measurement function eliminates the need for an external current shunt or transformer. Load current of the UUT (Unit Under Test) can be read directly on the large LCD display to 0.1 A. For additional protection, a current limit function can be set from zero to the maximum current available.

High peak current capability of more than three times the RMS current allows the P Series to drive non-linear loads.

 

Features

  • Low THD
  • 800 VA to 1250 VA Output Power
  • Portable Power, Low Cost
  • Simple Front Panel Operation
  • 16 Hz to 500 Hz Frequency Range
  • High Peak Current Capability
  • Remote Control Option
Download Data Sheet
Print
Email

Specifications

Controller

Type

Programmable

Controls

Digital Encoders

Readout Voltage

4 digit LCD

Readout Freqency and Current

4 digit LCD

Non Volatile Setups 
(with Option -232)

8

Output Ratings

 

Model

801P

1001P

1251P

AC Power

810 VA

1000 VA

1250 VA

Voltage

Range Low

0-135 V(L-N)

0-135 V(L-N)

0-135 V(L-N)

Range High

0-270 V(L-N)

0-270 V(L-N)

0-270 V(L-N)

Accuracy @ 50/60 Hz

± 1 % FS

± 1 % FS

± 1 % FS

Accuracy @ 40 Hz

± 2 % FS

± 2 % FS

± 2 % FS

Resolution

0.1 V

0.1 V

0.1 V

Line & Load Regulation lo range

± 1 % FS

± 1 % FS

± 1 % FS

Line & Load Regulation hi range

± 0.5 % FS

± 0.5 % FS

± 0.5 % FS

Total Harmonic Distortion @ 50/60 Hz

< 0.55 % typical

< 0.55 % typical

< 0.55 % typical

Output Noise

< 0.1 V typical

< 0.1 V typical

< 0.1 V typical

Frequency (specifications valid from 45 Hz to 500 Hz)

Range

16 – 500 Hz

16 – 500 Hz

16 – 500 Hz

Accuracy

± 0.02 %

± 0.02 %

± 0.02 %

Resolution below 100 Hz

0.1 Hz

0.1 Hz

0.1 Hz

Resolution above 100 Hz

1 Hz

1 Hz

1 Hz

Current

Current – Steady State lo range

6.0 ARMS

7.4 ARMS

9.2 ARMS

Current – Steady State hi range

3.0 ARMS

3.7 ARMS

4.6 ARMS

Peak Current lo range

17.8 A

22.2 A

27.6 A

Peak Current hi range

8.9 A

11.1 A

13.8 A

Protection

Current limit Mode

Programmable

Current limit Resolution

0.1 ARMS

Over Temperature

yes

Over Voltage

yes

Input

Model

801P

1001P

1251P

Line Voltage 2 wire + GND

100 – 240 ±10 % VRMS

100 – 240 ±10 % VRMS

100 – 240 ±10 % VRMS

Input Current

<15 ARMS

< 15 ARMS

< 20 ARMS

Line Frequency

47 – 63 Hz

47 – 63 Hz

47 – 63 Hz

Holdup Time

20 ms

20 ms

20 ms

Power Factor

> 0.95 typical

> 0.95 typical

> 0.95 typical

Measurements

Current Range

0.0 – 10.0 ARMS

0.0 – 10.0 ARMS

0.0 – 10.0 ARMS

Current Accuracy

± 0.2 ARMS

± 0.2 ARMS

± 0.2 ARMS

Current Resolution

0.1 A

0.1 A

0.1 A

Voltage Range

0 – 278 V

0 – 278 V

0 – 278 V

Voltage Resolution (requires Option -232)

1 (below 250 V) V

1 (below 250 V) V

1 (below 250 V) V

Remote Control Option -232

Interface type

RS232C

Baud rate

9600

Command Language

SCPI

Physical

Dimensions inches HxWxD

8.25 x 8.5 x 17.5

Dimensions mm HxWxD

210 x 216 x 445

Weight

30 lbs / 13.6 kg

Operating Temp.

0 – 40 ° C

* Specifications are warranted over an ambient temperature range of 0 to 40 °C and apply after a 30 minute warmup period.