California Instruments RS270 High Power AC&DC Power Source 270kVA
Description
The RS Series consists of multiple high power AC and DC power systems that provide controlled AC and DC output for ATE and product test applications. This high power AC and DC test system covers a wide spectrum of AC and DC power applications at an affordable cost. Using state-of-the-art PWM switching techniques, the RS series combines compactness, robustness and functionality in a compact floor-standing chassis, no larger than a typical office copying machine. This higher power density has been accomplished without the need to resort to elaborate cooling schemes or additional installation wiring. Simply roll the RS unit to its designated location (using included casters), plug it in, and the RS series is ready to work for you.
Features
- High Power AC and DC Power Source
Programmable AC and DC power for frequency conversion and product test applications - Expandable Power Levels
Available output power of 90 kVA per unit and multi-unit configurations for power requirements up to 540 kVA and above - Arbitrary & Harmonic Waveform Generation
User defined voltage waveform and distortion programming - Regenerative, bidirectional “Green” Power Solution
Automatic crossover between Source and Sink power mode offers regenerative capabilities. Regenerate up to 100% of the rated output power back to the utility grid during sink mode operation. (-SNK option) - Remote Control
Standard RS232C & USB along with optional IEEE-488 & LAN Interfaces are available for automated test applications
Specifications
Operating Modes |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RS90 |
AC, DC and AC+DC |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Mode Output |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frequency |
Range: 16.00-819.0 Hz, -LF Option: 16.00-500.0 Hz, -HF Option: 16.00-1000 Hz (supplemental specifications apply above 819 Hz). Resolution: 0.01 Hz: 16.00 – 81.91 Hz, 0.1 Hz: 82.0 Hz – 819.1 Hz, 1 Hz: 820-1000 Hz, SNK 16-500Hz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Phase Outputs |
3 Phase, Neutral Floating, Coupling DC (except -HV Opition and -XU) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Total Power |
RS90: 90kVA, RS180: 180kVA, RS270: 270kVA, RS360: 360kVA, RS450: 450kVA, RS540: 540kVA. Please consult factor for power levels above 540kVA |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Load Power Factor |
0 to unity at full output current |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Mode Voltage |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage Ranges
External Sense |
Range |
V Low |
V High |
|
< 0.25 % FS DC to 100 Hz,
< 0.1% FS for 10 % line change
|
||||||||||||||||||||||||||||||||||||||||||||||||||||
AC |
0-150 V |
0-300 V |
Load Reg
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC + DC |
0-150 V |
0-300 V |
Line Reg |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage drop compensation (5% Full Scale) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Harmonic Distortion (Linear) |
Less than 0.5% from 16 – 66 Hz, Less than 1% from 66 – 500 Hz, Less than 1.25% above 500 Hz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC Offset |
< 20 mV |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Load Regulation |
0.25% FS @ DC – 100 Hz, 0.5% FS > 100 Hz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
External Amplitude Modulation |
Depth: 0 – 10 %, Frequency: DC – 2 KHz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage slew rate |
200 µs for 10% to 90% of full scale change into resistive load, 0.5V / µSec |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Mode Current |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Steady State AC Current @ Full Scale Voltage Output
Peak Repetitive AC Current |
Model |
RS90 |
RS180 |
RS270 |
RS360 |
RS450 |
RS540 |
||||||||||||||||||||||||||||||||||||||||||||||||||
V Low |
200A |
400A |
600A |
800A |
1000A |
1200A |
|||||||||||||||||||||||||||||||||||||||||||||||||||
V High |
100A |
200A |
300A |
400A |
500A |
600A |
|||||||||||||||||||||||||||||||||||||||||||||||||||
Note: Constant power mode provides increased current at reduced voltage. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Up to 3.6 x rms current at full scale voltage |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Programming Accuracy |
Voltage (rms): ± 0.3 Vrms, Frequency: ± 0.01 % of programmed value, Current Limit: – 0 % to + 5 % of programmed value + 1A, Phase: < 0.5° + 0.2°/ 100 Hz with balanced load |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Programming Resolution |
Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 – 81.91 Hz, 0.1 Hz from 82.0 – 819 Hz, Current Limit: 0.1 A, 3 phase mode, 1.0 A, 1 phase mode, Phase: 0.1° |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Mode Current |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Steady State AC Current @ FS V |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parameter |
Frequency |
RMS |
RMS |
Peak Current |
VA |
Real Power |
Power Factor (>0.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||
Range |
16.00 – |
0-400V |
0 – 300A |
0 – 800 Amps |
0–90 |
0–90 |
0.00 – |
||||||||||||||||||||||||||||||||||||||||||||||||||
Accuracy* (±) |
0.01% + |
0.05V |
0.5A |
0.5A +0.2%, |
90VA |
90W |
0.01, <100Hz |
||||||||||||||||||||||||||||||||||||||||||||||||||
Resolution* |
0.01 to 81.91Hz |
0.01V |
0.01A |
0.01A |
10VA |
10W |
0.01 |
||||||||||||||||||||||||||||||||||||||||||||||||||
Note: Constant power mode provides increased current at reduced voltage. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Measurements – Harmonics |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Parameter |
Range |
Accuracy* (±) |
Resolution |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frequency Fundamental
Phase |
16.00 – 820 Hz |
0.03% + 0.03 Hz |
0.01 Hz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Frequency harmonics |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RS90 RS180 RS270 RS360 RS450 RS540 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
32.00 Hz – 16 KHz |
0.03% + 0.03 Hz |
0.01 Hz |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
RS90-3Pi |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
32.00 Hz – 48 KHz |
0.03% + 0.03 Hz |
0.01 Hz |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
0.0 – 360.0° |
2° typ. |
0.5° |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage |
Fundamental |
0.75V |
0.01V |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Harmonic 2 – 50 |
0.75V + 0.3% + 0.3%/kHz 0.01V |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Current |
Fundamental |
0.5A |
0.1A |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
Harmonic 2 – 50 |
0.15A + 0.3% + 0.3%/kH 0.1A |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Note: For current measurements, specifications apply from 2% to 100% of measurement range. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC Mode Output |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power |
Maximum DC Power at full scale of DC voltage range. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage Ranges |
Range: Low (0 – 200 V), High (0 – 400 V) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Accuracy |
± 1 Vdc |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Load Regulation |
< 0.25 % FS |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Line Regulation |
< 0.1% FS or 10 % line change |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Ripple |
< 2 Vrms Lo Range, < 3 Vrms Hi Range |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DC Mode AC+DC Mode |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Current Limit |
Programmable from 0 A to max. current for selected range |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC+DC Mode Output |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Power |
Maximum current and power in AC+DC mode is same as DC mode |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Protection |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Over Load |
Remote shutdown, External Sync, Clock/Lock |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Outputs |
Function Strobe / Trigger out, Clock/Lock |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
System Interface |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inputs |
Remote shutdown, External Sync, Clock/Lock |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Outputs |
Function Strobe / Trigger out, Clock/Lock |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Remote Control |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
IEEE-488 Interface |
IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RS232C Interface |
9 pin D-shell connector (Supplied with RS232C cable) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LAN ( option ) |
Ethernet Interface: 10BaseT, 100BaseT, RJ45 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
USB |
Version: USB 1.1; Speed: 460 Kb/s maximum |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Output Relay |
Push button controlled or bus controlled output relay |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Waveforms |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Waveform Types |
Sine, Square, Clipped sine, User defined |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
User defined waveform storage |
Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200. One group can be active at a time |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Input |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Voltage |
Must be specified at time of order. All inputs are L-L, 3ø, 3 wire + Gnd. 208 ± 10% VAC, 230 ± 10% VAC, 400 ± 10% VAC, 480 ± 10% VAC |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Line Voltage |
208 VLL ±10%, 230 VLL ±10%, 400 VLL ±10%, 480 VLL ±10% |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Line VA |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Line Frequency |
47 – 63 Hz |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Efficiency |
85 % (typical) depending on line and load |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Power Factor |
0.95 (typical) / 0.99 at full power. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inrush Current |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Hold-Up Time |
>10ms |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Isolation Voltage |
2200 VAC input to output, 1350 VAC input to chassis |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
AC Service |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inputs/Outputs |
Rear Panel Access |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Regulatory |
IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
EMI |
CISPR 11, Group1 , Class A |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Connectors |
AC Input and Output terminal blocks behind rear panel access cover. IEEE-488 (GPIB) connector behind rear panel access cover. 9 pin D-Shell RS232C connector*, behind rear panel access cover. Remote voltage sense terminal block behind rear panel access cover. System Interface Connector, DB-37 behind rear panel access cover. *RS232 DB9 to DB9 cable supplied |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Physical Dimensions |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RS90 Dimensions |
Height: 74.5″ (1892.3 mm) , Width: 30.3″ (769.6mm), Depth: 38.3″ (972.8mm), |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RS90 Weight |
Net: 2150 lbs / 975 Kg approximately, Shipping: 2450 lbs / 1111 Kg approximately |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Chassis |
RS90: Casters and forklift openings |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Vibration and Shock |
Designed to meet NSTA project 1A transportation levels. Units are shipped in wooden crate with forklift slots |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Air Intake/Exhaust |
Forced air cooling, front air intake, rear exhaust |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Humidity |
0 to 95 % RAH, non condensing |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Temperature |
Operating: 0-35* (30*C max is CP mode), Storage -20 to +85*C |