Elgar TW 5550 AC Power Source 1ø to 3ø Power 5550 VA
Description
The Elgar TrueWave (TW) is designed for testing today's complex electronics, including avionics and commercial applications requiring DC and sine wave testing. The TW is ideal for testing electronic equipment for compliance to new European Standards such as harmonics.
Features
- Measurements that can be made:
- Peak Inrush Current
- Phase to Neutral rms Output Voltages
- Phase to Phase rms Output Voltages
- rms Output Currents
- Peak Current
- Output Frequency
- 1ø to 3ø Power
- 1ø to 3ø VA
- 1ø to 3ø VA
- Output Phase Angles Relative to Phase A
- IEC Flicker Test Capable
- Field Parallel Configurable
- 3 phase output from a single unit
- Low Harmonic Distortion
- DC Output
Specifications
Common |
|
Standard Features |
1ø to 3ø programmable (TW 5250 only) |
Programmed Settings |
The Sync out selections are: |
Interface |
IEEE-488.2 interface and RS-232 |
Protocol |
SCPI protocol |
Certifications |
CE marked and FCC compliant |
Calibration Interval |
1 year |
Input |
|
Voltage Ranges |
Factory configured 187 to 264 Vrms, 3ø L-L (3 wire). A chassis ground is also required. |
Power Factor |
0.6 (0.99 with input PFC option, 0.35 for European rectifier input) |
Frequency Range |
47 to 63 Hz |
Efficiency |
70% min, at full load |
Ride Through |
3 ms, min for rectifier input; 10 ms, min, with PFC option |
Output |
|
Power |
1750 VA, 3500 VA or 5250 VA |
Phase |
1750 VA, 1 phase; 3500 VA, 1 or 2 phase; 5250 VA, 1, 2 or 3 phase |
AC Output Voltage |
0 to 156 Vrms L-N low range |
DC Output Voltage |
0 to 207V low range |
Current Per Phase |
13A to 135V in 156V range; 6.5A to 270V in 312V range (per 1750 VA module); 16A to 115V in low range; 8A to 230V in high range (per 1850Va module) |
Power Factor of Load |
0 lagging to 0 leading |
Crest Factor |
4.0 (peak output current to rms output current) |
Frequency Range |
45 Hz to 500 Hz |
Max Total Harmonic Distortion |
0.3% max (Full Linear Load or No Load) |
AC Noise Level |
60 dB rms below full output voltage |
Amplitude Stability With Remote Sense |
±0.1% of full scale over 24 hours at constant line, load and temperature |
Line Regulation |
0.05% of full scale for a ± 10% change in line voltages |
Load Regulation |
0.15% of full scale |
Voltage Accuracy |
± 0.1% of full scale |
Voltage Resolution |
0.03% of full scale |
Frequency Resolution |
0.1 Hz |
Phase Accuracy |
Phase-to-Phase Balanced Linear Resistive Load: ±1° |
Phase Angle Resolution |
0.1° |
Remote Output Voltage Sense |
5 Vrms total lead drop, max |
Environmental |
|
Operating Temperature |
0°C to 45°C (32°F to 113°F) |
Storage Temperature |
-40°C to 70°C (-40°F to 158°F) |
Cooling |
Air is drawn in primarily from the front, but also from the top, bottom, and sides and exhausted through the rear. |
Humidity (Non-condensing) |
0 to 85%, 31°C (88°F); derate to 50% at 40°C (104°F) |
Altitude |
Operating 6,500 ft. Non-operating 40,000 ft |
Physical |
|
Dimensions |
Width: 19″ (483 mm) |
Weight |
TW 1750 – 60 lbs. (27.3 kg), TW 3500 – 83 lbs. (37.7 kg), TW 5250 – 108 lbs. (49 kg) |
Shipping Weight – US |
TW 1750 – 130 lbs. (59 kg), TW 3500 -153 lbs. (69.5 kg), TW 5250 – 178 lbs. (80.9 kg) |
Measurement Accuracy All at 25° ± 5°C |
|
Power |
2.5% of full scale |
Voltage |
0.3% of full scale + 0.2% of reading |
Shipping Weight |
12.7 lbs. (5.8 kg) |
Current |
0.3% of full scale + 0.5% of reading |
Apparent Power |
2.5% for output > 200 VA |
Frequency |
0.25% |
Phase |
0.5° |
Protection and Safety |
|
Overvoltage Shutdown |
Programmable for 20V to 255V peak, 156V range; 40V to 510V peak, 312V range |
Programmable Current Limit Shutdown |
Settable to 1% of range (0.5A to 13A for 156V range; 0.5A to 6.5A for 312V range) |
Programmable Current Limit |
Settable to 1% for range; the timeout is settable from 10 ms to 10s |
Programmable Constant Current |
Settable to 1% of range (0.5A to 13A for 156V range; 0.5A to 6.5A for 312V range). For all current accuracies, add ± 1.5%/ kHz above 500 Hz. For paralleled amplifiers, add ± 1%. |
Over temperature Shutdown |
Automatic, not programmable |