Rohde & Schwarz FPL1003 Spectrum Analyzer 5 kHz – 3 GHz

Description

Rohde & Schwarz FPL1003 Spectrum Analyzer 5 kHz – 3 GHz makes measuring fast and simple. The R&S®FPL1003 supports many applications such as power measurements and the analysis of digital and analog modulated signals. The solid RF performance makes it the ideal instrument for use in the lab, production and service. Its light weight and battery operation capability lets you take it anywhere to perform measurements.

 

MODEL SERIES OVERVIEW

FPL1000-series Spectrum Analyzers 5 kHz to 7.5 GHz

Features

  • Frequency range 5 kHz to 3 GHz
  • SSB phase noise: typ. –108 dBc (1 Hz) at 10 kHz (1 GHz carrier) offset
  • DANL with preamplifier: typ. –166 dBm from 10 MHz to 2 GHz
  • Lightweight with small footprint
  • 40 MHz analysis bandwidth (option)
  • Battery or 12 V/24 V DC operation (option)
Download Data Sheet
Print
Email

Specifications

Frequency
Frequency range R&S®FPL1003 5 kHz to 3 GHz
Bandwidth
Resolution bandwidth (–3 dB) sweep filters 100 kHz to 10 MHz in 1/2/3/5 sequence
FFT filters 1 Hz to 50 kHz in 1/2/3/5 sequence
Signal analysis bandwidth (equalized) standard nom. 10 MHz
with R&S®FPL1-B40 option nom. 40 MHz
Displayed average noise level (DANL)
RF preamplifier off 5 kHz ≤ f < 100 kHz typ. –143 dBm
100 kHz ≤ f < 5 MHz < –140 dBm, typ. –143 dBm
5 MHz ≤ f < 3 GHz < –149 dBm, typ. –152 dBm.
RF preamplifier on (gain nom. 20 dB) 3 MHz ≤ f < 10 MHz < –155 dBm, typ. –158 dBm
10 MHz ≤ f < 2 GHz < –163 dBm, typ. –166 dBm
2 GHz ≤ f < 3 GHz < –162 dBm, typ. –165 dBm
Attenuation and Gain
Setting range of attenuator standard 0 dB to 45 dB, in 5 dB steps
with R&S®FPL1-B25 option 0 dB to 45 dB, in 1 dB steps
PRF preamplifier gain with R&S®FPL1-B22 option nom. 20 dB
Intermodulation
1 dB compression of input mixer (two-tone) RF attenuation 0 dB, RF preamplifier = off nom. +7 dBm
Third-order intercept point (TOI) RF attenuation 0 dB, level 2 × –20 dBm, ∆f > 5 × RBW or 10 kHz, whichever is larger, RF preamplifier = off
10 MHz ≤ fin < 300 MHz > 13 dBm, typ. 16 dBm
300 MHz ≤ fin < 3 GHz > 17 dBm, typ. 20 dBm
with R&S®FPL1-B22 option, RF attenuation 0 dB, level 2 × –40 dBm, ∆f > 5 × RBW or 10 kHz, whichever is larger, RF preamplifier = on
Phase noise
SSB phase noise frequency = 1000 MHz, carrier offset
100 Hz nom. –88 dBc (1 Hz)
1 kHz < –99 dBc (1 Hz)
10 kHz < –105 dBc (1 Hz), typ. –108 dBc (1 Hz)
100 kHz < –110 dBc (1 Hz), typ. –115 dBc (1 Hz)
1 MHz < –130 dBc (1 Hz), typ. –135 dBc (1 Hz)
10 MHz nom. –152 dBc (1 Hz)
Overall Amplitude Accuracy
Total measurement uncertainty signal level 0 dB to –50 dB
below reference level, S/N > 20 dB,
sweep time auto, sweep type = FFT,
RF attenuation 10 dB, 20 dB,
30 dB, 40 dB, RF preamplifier = off,
span/RBW < 100, confidence level 95 %,
+20 °C to +30 °C
0.5 dB
1 MHz ≤ f < 3 GHz 0.5 dB
3 GHz ≤ f < 7.5 GHz 0.8 dB
Watch Product Promo
Stay informed

To keep you in the loop of our latest news, register now for our email newsletter.