ETS-Lindgren 5407 GTEM Test Cell for Radiated Emissions and Immunity Testing
Description
ETS-Lindgren 5407 GTEM Test Cell for Radiated Emissions and Immunity testing enables users to perform tests in less time than either an OATS or a chamber. Tests can be performed quickly and accurately throughout the product life cycle. Beginning with design qualification testing, and moving through to pre-compliance testing, full-compliance testing and production sampling, the model 5407 is a time saving device for your test lab. A typical radiated emissions test (10,000-point scan) can be completed in 15 minutes or less, while a typical radiated immunity test can usually be completed in half the normal time.
Features
- Post production
- Pre-compliance
- Design qualification
- Full Compliance IEC 61000-4-3 ANSI C63.4
Download Data Sheet
Print
Email
Specifications
Electrical Specifications | |
Feed Connector Type | cw 7/16 DIN to N Adapter |
Field Uniformity | f <= 1 GHz, 0 -6dB |
Frequency | 9 kHz – 5 GHz (RE) 1 DC – 20 GHz (RI) 2 |
Input Impedance | 50 Ω |
Maximum CW Input | 200 (500 W with optional blower) W |
Shielding Effectiveness | 10 kHz – 1 GHz From Internal E-Fields 80 dB min |
VSWR Maximum | All Other Freq <= 1.50:1 Characteristic Freq <= 1.75:1 |
VSWR Typical | All Other Freq 1.30:1 Characteristic Freq3 1.75:1 |
Physical Specifications | |
Approx Cell Weight | 500.0 kg ( 1,102.30 lb ) |
Door Dimension Primary (H) | 747 mm (29.41 inches) |
Door Dimension Primary (W) | 686 mm (27.01 inches) |
Door Dimension Secondary (H) | 385 mm (15.16 inches) |
Door Dimension Secondary (W) | 460 mm (18.11 inches) |
Highest Accuracy Transverse Test Surface in Center of Cell (H)4 | 250 mm (9.84 inches) |
Highest Accuracy Transverse Test Surface in Center of Cell (W)4 | 350.0 mm (13.78 inches) |
Maximum Recommended Transverse Test Surface in Center of Cell (H)5 | 500.0 mm (19.69 inches) |
Maximum Recommended Transverse Test Surface in Center of Cell (W)5 | 560 mm (22.05 inches) |
Maximum Septum Height3 | 760 mm (29.92 inches) |
Outer Cell w/Base Dimension(H)1 | 2.1 m (6.89 ft) |
Outer Cell w/Base Dimension(L) | 4.0 m (13.12 ft) |
Outer Cell w/Base Dimension(W) | 2.2 m (7.22 ft) |