AWT Global Radar Signal Generators
Description
AWT(G) Radar Simulators generate a variety of Radar Signals. The Simulators are ideal for radar receiver testing and in training Radar Operators on object detection, recognition and Electronic Warfare (EW). The simulators offer variety of simulation capabilities; including Radar Warning Receivers (RWR), Missile Warning Receivers (MWR) and other Electronic Warfare (EW) Receivers.
AWT’s Radar Simulator can generate up to 128 simultaneous CW or Pulsed signals. An intuitive graphical user interface (GUI) makes it easy to program signal parameters. Geographic Information System (GIS) tools are also available (optional). The receiving band(s) are developed to customer specifications. They are available in the range from 0.5 GHz and 40 GHz.
Features
- Replicates real radar signal characteristics (Frequency, Phase, Pulse, Modulation, SCAN).
- Simulation Scenarios: AOA Simulation, Radar Activity, Virtual Missions.
- Ideal for Electronic Warfare training and Radar receiver testing.
- 19” Standard Rack Mountable and Portable models are available.
- Signal data library with up to 1024 entries.
Specifications
Frequency |
|
Range |
0.5 – 40 GHz |
NATO Bands |
C, D, E, F, G, H, I , J, K |
IEEE Bands |
UHF (upper), L, S, C, X, Ku, K, Ka |
Resolution |
1 MHz |
Accuracy |
1 kHz (higher accuracy on request) |
Type |
Fixed, Agile (Sinusoid, Saw-Tooth, Triangular, Rectangular, Random), Hopping (up to 256 / sec) |
Pulse |
|
Type |
CW, Stable, Jitter, Stagger (32 Steps), Dwell & Switch, Random |
Width Range |
0.05 – 225 us |
Repitition Interval |
1us – 1 sec |
Density |
Up to 1,000,000 pulses / sec (PPS) |
FMOP |
Linear, Non-Linear |
PMOP Agile |
Bi-Phase, Quadratic-Phase |
Frequency Modulation on Pulse (FMOP) |
|
Pattern |
Linear, non-Linear, Chirp up/down |
Agile |
Sine, Triangular |
Range |
10 – 512 MHz |
Accuracy |
1 MHz |
Phase Modulation on Pulse (PMOP) |
|
Pattern |
Bi-Phase, Quadratic Phase |
Change Time |
< 50 ns |
Accuracy |
better than 20° |
SCAN |
|
Types |
Electronic (Agile Beam), Conical, TWS, Steady, Sector, Lobe Switching, Circular, Helical, Raster, Bi-Directional, Use defined |
Rate |
50ms – 10 sec |
AM |
0 – 40 dB |
Output |
|
Number of RF Signals per Bank |
1 CW + 1 Pulse Doppler Signal, or |
Ports per Bank |
1 Vertical Polarization, |
Power (Signal) |
> 15 dBm (other power levels on request) |
Monitoring Port |
> 5 dBm (other power levels on request) |
Communication Interfaces |
|
Ethernet (IEEE 802.3), USB, RS-232 |
|
Dimensions / Weight / Environment / Electrical |
|
Dimensions |
Depends on model and configuration |
Weight (frequency |
Depends on model and configuration |
Power |
110-240V +/- 10% |
Power Consumption |
Depends on model and configuration |