Haefely Hipotronics PEFT 8010 EFT/Burst Immunity Test System 7.3kV

Description

Haefely Hipotronics PEFT 8010 EFT/Burst Immunity Test System 7.3kV is a state-of-the-art system with a built-in coupling/decoupling network for single phase or three-phase mains supply lines and a HV terminal to connect a capacitive coupling clamp IP4B. The spike frequency can be varied from as low as 1Hz to 110kHz.

The PEFT 8010 is capable to generate 999 spikes per millisecond or up to 250 spikes per burst. Its performance fully complies with IEC 61000-4-4:2004, IEC 61000-4-4 Amd.1 Ed.2:01/2010 and IEC 61000-4-4 Ed.3: 03/2012. Pre-programmed Standard Test routines and several selected User Test routines make the PEFT 8010 an optimum standalone solution for both testing during development and final testing of products and sub-assemblies.

Features

  • EFT impulse generation
  • ESD control and report functions
  • Automatic test operation
  • Data exchange
  • Compact and reliable
  • Remote control
  • ISO 9001:2000
Download Data Sheet
Print
Email

Specifications

Wave Shape into 50Ω load
Rise time 5 ns ± 30 %
Impulse duration 50 ns ± 30 %
Wave Shape into 1000Ω load
Rise time 5 ns ± 30 %
Impulse duration 50 ns – 15 / + 100 ns
Burst Characteristic
Voltage at HV-output

Voltage at CDN output

1.0 … 7.3 kV

1.0 … 6.6 kV

Spike frequency 1 Hz … 110 kHz
Burst duration 0.01 … 999 ms
Burst period 0.1 Hz … 400 Hz

2.5 ms … 10 s

1 period … 500 periods

Impulses per second Max. 250 for Unom > 4 kV

Max. 500 for Unom ≤ 4 kV

Impulses per burst Max. 75 for Unom > 4 kV

Max. 150 for Unom ≤ 4 kV

Spike distribution normal, continuous, random, real
Polarity positive, negative
Test time 10 s … 8 h per path
Single Phase Coupling/Decoupling Network
Maximum AC voltage 264 V @ 16 … 440 Hz
Maximum AC current 16 A @ 50 … 60 Hz, 10 A @ 400 Hz
Maximum DC voltage 125 V
Maximum DC current 16 A (dependant on DC voltage)
Coupling Modes L-GND, N-GND, PE-GND, LN-GND, LPE-GND, NPEGND, LNPE-GND
Residual voltage at Test Supply Input ≤ 10% of applied test voltage
Synchronization
Frequency 16 2/3 Hz, 40 Hz, 50 Hz, 60 Hz, 400 Hz, auto
Impulse trigger automatic, manual, external
System Configuration
EUT fail input BNC, logic low to trigger
P90 interface for a 3-phase CDN extension
PESD interface for connecting an ESD generator
Printer interface Centronix
Computer interface RS-232, IEEE-488 (optional)
Power Supply
Voltage 85 … 264 VAC, 150 VA
Frequency 50 / 60 Hz
Weight and Dimension
Weight 14 kg
W x H x D 450mm x 130mm x 570mm