Haefely PSURGE 30.2 Modular 30kV / 30kA Surge Test System

Description

This test system is used to perform high energy surge tests. Energy surges are generated by atmospheric lightning in power circuits. A surge is characterized by high energy and relative fast front times. Pulse durations are widely variable as are the coupling paths.

The PSURGE 30.2 is designed to generate a broad variety of surge impulses. Impulse modules can be exchanged quickly allowing PSURGE 30.2 to be used for different applications. Impulse module type is detected by the system software.

The built-in microprocessor control unit serves as user interface and control all the internal functions. When adding the remote control option, it is possible to use the PSURGE 30.2 with the WinPATS control and reporting software.

The integration in the WinPATS control and reporting software package enhances an efficient set-up and operation of this test system. Most importantly, the test load can be transferred to a computer freeing valuable resources. An integrated test cabinet provides optimal and safe connections for component testing.

Features

  • Up to 30kV impulse voltage
  • Up to 30kA impulse current
  • Automatic polarity switching
  • Peak voltage and current monitoring
  • Integrated large test cabinet
  • Remote control option

Applications

  • Combination wave according IEC 61000-4-5
  • Safety tests as defined e.g. in IEC 61010
  • Telecom system tests according ITU K series
  • Surge tests as described e.g. in IEC 60060-1 and ANSI C62.41
  • Component test as described e.g. in IEC 60664 and IEC 61643-1
  • Many IEC & EN Product standards
Download Data Sheet
Print
Email

Specifications

PSURGE 30.2 Mainframe
Charging voltage range 3…33kV
Capacitors 9uF / 36uF
Stored energy 5kJ at max. charging voltage
HV output terminals inside the test cabinet
Power mains 208, 230 or 240V

50/60Hz, 1800VA

HV switch triggered spark gap
Impulse polarity positive, negative, alternating
Impulse circuit floating, max. voltage between common and ground 500V AC
External synchronization 0°….360° in 1° steps
Dimensions (W x D x H)
PSURGE 30.2 60 x 100 x 190 cm
Test cabinet 39 x 29 x 32 cm
Weight approx. 320 kg
Impulse Module PS30-CW
Impulse type Combination wave
Voltage front time 1.2us ±30%
Voltage decay time 50us ±20%
Voltage undershoot ≤30%
Voltage amplitude range 3…30kV
Impulse repetition Up to 6 impulses per minute at max. voltage
Output impedance 2 Ohm
Current front time 8us ±20%
Current decay time 20us ±20%
Current undershoot ≤30%
Current amplitude range 1.5…15kA
Impulse Module PS30-8×20
Impulse type Current
Voltage front time not defined
Voltage decay time not defined
Undershoot not defined
Charging voltage range 3…15kV
Impulse repetition Up to 2 impulses per minute at max. current
Output impedance 0.5 Ohm
Current front time 8us ±20%
Current decay time 20us ±20%
Undershoot ≤20%
Current amplitude range 6…30kA
Impulse Module PS30-10×350
Impulse type current
Voltage front time not defined
Voltage decay time not defined
Charging voltage range 3…15kV
Impulse repetition Up to 2 impulses per minute at max. current
Output impedance 12 Ohm
Current front time 10us ±20%
Current decay time 350us ±20%
Current amplitude range 240…1200A
Impulse Module PS30-10×1000
Impulse type Current
Voltage front time not defined
Voltage decay time not defined
Charging voltage range 3…15kV
Impulse repetition Up to 2 impulses per minute at max. current
Output impedance 37 Ohm
Current front time 10us ±20%
Current decay time 1000us ±20%
Current amplitude range 80…400A
Coupling and decoupling network FP-SURGE 3010
Impulse shape Combination wave only
EUT line voltage 480V AC

110V DC

EUT current 10A
Imp. amplitude 30kV / 15kA
Coupling modes Line to neutral

Line or neutral to ground

Line and neutral to ground

Coupling capacitors 2x9uF / 1x18uF
Residual voltage at EUT line input 15% of the applied test voltage, limited to approx. 1200V
Dimensions (W x D x H)
FP-SURGE 3010 60 x 100 x 190 cm
Test cabinet 40 x 40 x 80 cm
Weight
FP-SURGE 3010 approx. 250 kg