California Instruments - 2001RP 2000 VA Single-Phase AC Power Source

Description

The 2001RP is a 2000 VA programmable, single-phase AC source 16 Hz to 5000 Hz frequency output. It is a small, lightweight source of AC power for applications that require variable voltage and frequency at power levels up to 2000 VA. 103 – 127 V or 187 – 253 V, 47 – 440 Hz input. It has dual LCD readouts for programmed settings of voltage, current limit and frequency. It is equipped with over current, over temperature, and over voltage protection.

 

Features

  • 16 Hz to 5000 Hz
  • Dual output voltage ranges, 0-300 or 150 VAC
  • Full power with up to 3.3:1 crest factor loads
  • Standard Current measurement
  • Optional measurements for Peak Current, Voltage, Real Power, Apparent Power, Power Factor
  • Simple Front Panel and Rear panel Connections
  • Optional GPIB and RS-232C interfaces
  • Made in USA
  • CE Mark
Download Data Sheet
Print
Email

Specifications

Controller

Type

Programmable

Controls

Digital Encoders

Readouts

dual 4 digit LCD's

Non Volatile Setups

8 (with –OP1 option)

Output

Phases

1

AC Power

2000VA

Load Connection Floating Neutral

Rear panel terminal block

Output Voltage

High Range /  Low Range

0-300 / 0-150V (L-N)

Accuracy

± 0.1 %FS @ 16 Hz – 100 Hz

Accuracy

± 0.2 %FS @ 100 Hz – 5000 Hz

Resolution

0.1 V

Line & Load Regulation High V Range

± 0.5 %FS

Line & Load Regulation Low V Range

± 1 %FS

Load Regulation 10 % Line Change

± 0.1 %FS

T.H.D

0.5 typical % @ 16 Hz – 5000 Hz

Output Noise

< 0.1 V typical

Output Frequency

Range

16 – 5000 Hz

Accuracy

± 0.02%

Resolution below 100 Hz

0.01Hz

Resolution above 100 Hz

1 Hz

Output Current

Steady State Current High V Range

6.7 A rms

Steady State Current Low  V Range

 13.4 A rms

Peak Current High V Range

22.2 A peak

Peak Current Low V Range

44.5 A peak

Protection

Current Limit Mode

Programmable trip level: Output trips off

(Output shut off) Resolution

0.1 A rms

Over Temperature

Output shut off

Over Voltage

Output shut off

Input

Line Voltage 2 wire + GND

103-127 V rms Maximum operating range 187-253 V rms

Line Current (fused)

< 30 A rms

Line Frequency

47 – 440 Hz

Holdup Time

10 ms

Power Factor

> 0.95 typical

Isolation Input/output to Chassis

1350 V / 2200 V