Fluke 433 Three-Phase Power Quality Analyzer

Description

The Fluke 434 and 433 three-phase power quality analyzers help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use handheld tools have many innovative features to give you the details to pinpoint problems faster and safer.

 

Features

  • Complete three-phase troubleshooting tool:
    • Measures virtually every power system parameter: voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics and inter-harmonics.
    • Captures events like dips and swells, transients, interruptions and rapid voltage changes.
  • AutoTrend:
    • No time wasted setting up additional trend graphs while every measurement is automatically recorded.
    • Analyzes trends using cursors and zoom function, while recording continues in the background.
  • System-Monitor:
    • Gives immediate insight into power system’s quality.
    • Checks conformity to limits specified in EN50160 or to own custom limits.
  • Four channels:
    • Simultaneously measures voltage and current on all three phases and neutral.
  • Automatic transient display:
    • Captures up to 40 dips, swells, interruptions or transients automatically.
  • Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the service entrance.
  • Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH battery pack. Menu-driven interface simplifies operation.
  • Extensive data analysis possibilities. Cursors and zoom can be used ‘live’ while taking the measurements, or ‘offline’ on stored measurement data. The stored measurements can also be transferred to a PC with FlukeView software (included with Fluke 434).
  • Complete package includes everything to get started: 4 current clamps, 5 voltages test leads and clips, line adapter/battery charger and hard case.
  • Complies with IEC 61000-4-30 measurement standards.
Download Data Sheet
Print
Email

Specifications

Inputs

Number:

 4 voltage and current (3 phases + neutral)

Maximum voltage:

 1000 Vrms (6 kV peak)

Maximum sampling speed:

 200 kS/s on each channel simultaneously

Volt/Amps/Hertz

Vrms (AC + DC)

 

Measurement range:

 1 … 1000 V

Accuracy:

 0.5% of Vnom

 

 

Vpeak

 

Measurement range:

 1 … 1400 V

Accuracy:

 5% of Vnom

 

 

Crest factor

 

Measurement range:

 1.0 … > 2.8

Accuracy:

 ±5%

 

 

Arms (AC + DC)

 

Measurement range:

 0 … 20 kA

Accuracy:

 ±1% ± 5 counts

 

 

Apeak

 

Measurement range:

 0 … 5.5 kA

Accuracy:

 5%

 

 

Crest factor

 

Measurement range:

 1 … 10

Accuracy:

 ±5%

 

 

Hz (50 Hz nominal)

 

Measurement range:

 42.50 … 57.50 Hz

Accuracy:

 ±1% ± 5 counts

Dips and swells

Vrms (AC+DC) ³

 

Measurement range:

 0.0% … 100% of Vnom

Accuracy:

 ±1% of Vnom

 

 

Arms (AC+DC) ³

 

Measurement range:

 0 … 20 kA

Accuracy:

 ±1% ± 5 counts

Harmonics

Harmonic (interharmonic) (n)

 

Measurement range:

 DC, 1..50; (Off, 1..49) measured relative to fundamental or to total rms

 

 

Vrms

 

Measurement range:

 0.0 … 1000 V

Accuracy:

 ±5% ± 2 counts

 

 

Arms

 

Measurement range:

 0.0 … 4000 mV x clamp scaling

Accuracy:

 ±5% ± 5 counts

 

 

Watts

 

Measurement range:

 Depends on clamp scaling

Accuracy:

 ±5% ± n x 2% or reading, ± 10 counts

 

 

DC voltage

 

Measurement range:

 0.0 … 1000 V

Accuracy:

 ±5% ± 10 counts

 

 

THD

 

Measurement range:

 0.0 … 100.0%

Accuracy:

 ±2.5%

 

 

Hz

 

Measurement range:

 0 … 3500 Hz

Accuracy:

 ± 1 Hz

 

 

Phase angle

 

Measurement range:

 -360º … +360º

Accuracy:

 ± n × 1.5º

Power and energy

Watt, VA, VAR

 

Measurement range:

 1.0 … 20.00 MVA¹

Accuracy:

 ±1.5% ± 10 counts

 

 

kWh, kVAh, kVARh

 

Measurement range:

 00.00 …200.0 GVAh¹

Accuracy:

 ± 1.5% ± 10 counts

 

 

Power Factor/ Cos Ф / DPF

 

Measurement range:

 0…1

Accuracy:

 ± 0.03

Flicker

Pst (1 min), Pst, Plt, PF5

 

Measurement range:

 0.00 … 20.00

Accuracy:

 ±5%

Unbalance

Volts

 

Measurement range:

 0.0 … 5.0%

Accuracy:

 ±0.5%

 

 

Current

 

Measurement range:

 0.0 … 20%

Accuracy:

 ± 1%

Transient Capture

Volts

 

Measurement range:

 ±6000 V

Accuracy:

 ±2.5% of Vrms

Minimum detect duration

 5 µs (200kS/s sampling)

Inrush mode

Arms (AC+DC)

 

Measurement range:

 0.000 … 20.00 kA¹

Accuracy:

 ±1% of meas ± 5 counts

Autotrend recording

Sampling:

 Up to 100 readings/s continuous sampling per channel

Memory:

 Up to 3600 min, max and avg points for each reading

Recording time:

 Up to 450 days

Zoom:

 Up to 12x horizontal zoom

Memory

Screens:

 Fluke 434 – 50; Fluke 433 – 25

Data sets including recordings:

 Fluke 434 – 10; Fluke 433 – 5

Notes

¹

 Depending on clamp scaling

²

 50 Hz/60 Hz nominal frequency according to IEC 61000-4-30

³

 Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Environmental Specifications

Operating Temperature

 

 0 ºC to +50 ºC

Storage Temperature

 

 -20 ºC to +60 ºC

Operating Altitude

 

 3,000 m

Safety Specifications

Compliance

 

 IEC/EN61010-1 (2nd edition) pollution degree 2;

 

CAN/CSA C22.2 No 101.1

 

 ANSI/ISA S82.01

Mechanical & General Specifications

Size

 

 256 x 169 x 64 mm

Weight

 

 2 kg

Warranty

 

 3 years

Battery Life

Rechargeable NiMH pack:

 >7 hours

Charging time:

 4 hours typical

Shock & Vibration

 

 MiL-PRF-2880F Class 2

Case

 

 IP51 (dust, drip, waterproof)