Fluke 434/PWR Three- Phase Power Analyzer

Description

The Fluke 434/PWR power analyzer is the ideal tool for finding energy waste in commercial and factory buildings and equipment. Electricians, field service engineers and maintenance technicians can use this special edition instrument to conduct energy consumption studies and electrical load analysis, and to perform power quality logging and analysis according to EN 50160. Fluke's 434/PWR is a complete three-phase troubleshooting tool that measures virtually every power system parameter: voltage, current, frequency, power, energy consumption, cos f or power factor, unbalance, and harmonics and inter-harmonics.

 

Features

  • Captures events like dips and swells, interruptions and rapid voltage changes, based upon ½ cycle rms values
  • Unique AutoTrend gives you fast insight into changes over time
  • With a single push of a button, the unique System Monitor gives you an overview of power system performance. It also checks that incoming power complies to EN50160 limits or to your own custom specifications
  • Logger:
    • Detailed, user-configurable long-term recording gives you the MIN, MAX and AVG readings of up to 100 parameters on all four phases.
    • Averaging time can be selected down to 0.5 seconds (or 1 minute for 1 day’s recording, 10 minutes for 1 week, 30 minutes for 1 month or more
  • Two groups of four channels: simultaneously measure voltage and current on all three phases and neutral
  • Auto Scaling:
    • Easier trend analysis with automatic scaling of the vertical axis – so you will always view the waveforms on a full display
  • Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at service entrance
  • Extensive data analysis: cursors and zoom can be used ‘live’ while taking the measurements, or ‘offline’ on stored measurement data. The stored measurements can also be transferred to Power Log software
Download Data Sheet
Print
Email

Specifications

Inputs

Number:

 4 voltage and current (3 phases + neutral)

Maximum voltage:

 1000 Vrms (6 kV peak)

Maximum sampling speed:

 200 kS/s on each channel simultaneously

Volt/Amps/Hertz

Vrms (AC + DC)

 

Measurement range:

 1 … 1000 V

Accuracy:

 0.1% of Vnom

 

 

Vpeak

 

Measurement range:

 1 … 1400 V

Accuracy:

 5% of Vnom

 

 

Crest factor, voltage

 

Measurement range:

 1.0 … > 2.8

Accuracy:

 ±5%

 

 

Arms (AC + DC)

 

Measurement range:

 0 … 20 kA

Accuracy:

 ±0.5% ± 5 counts

 

 

Apeak

 

Measurement range:

 1.4x rms value

Accuracy:

 5%

 

 

Crest factor, A

 

Measurement range:

 1 … 10

Accuracy:

 ±5%

 

 

Hz 50 Hz nominal

 

Measurement range:

 40 … 70 Hz

Accuracy:

 ±0.01 Hz

Dips and swells

Vrms (AC+DC) ²

 

Measurement range:

 0.0% … 100% of Vnom

Accuracy:

 ±0.2% of nominal voltage

 

 

Arms (AC+DC) ²

 

Measurement range:

 0 … 20 kA'

Accuracy:

 ±1% ± 5 counts

Harmonics

Harmonic (interharmonic) (n)

 

Measurement range:

 DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7

 

 

Vrms

 

Measurement range:

 0.0 … 1000 V

Accuracy:

 ±0.05% of nominal voltage

 

 

Arms

 

Measurement range:

 0.0 … 4000 mV x clamp scaling

Accuracy:

 ±5% ± 5 counts

 

 

Watts

 

Measurement range:

 Depends on clamp scaling and voltage

Accuracy:

 ±5% ± n x 2% or reading, ± 10 counts

 

 

DC voltage

 

Measurement range:

 0.0 … 1000 V

Accuracy:

 ±0.2% of nominal voltage

 

 

THD

 

Measurement range:

 0.0 … 100.0%

Accuracy:

 ±2.5% V and A (± 5% Watt)

 

 

Hz

 

Measurement range:

 0 … 3500 Hz

Accuracy:

 ± 1 Hz

 

 

Phase angle

 

Measurement range:

 -360º … +360º

Accuracy:

 ± n × 1.5º

Power and energy

Watt, VA, VAR

 

Measurement range:

 1.0 … 20.00 MVA¹

Accuracy:

 ±1% ± counts

 

 

kWh, kVAh, kVARh

 

Measurement range:

 00.00 …200.0 GVAh¹

Accuracy:

 ± 1.5% ± 10 counts

 

 

Power Factor/ Cos Ф / DPF

 

Measurement range:

 0…1

Accuracy:

 ± 0.03

Unbalance

Volts

 

Measurement range:

 0.0 … 5.0%

Accuracy:

 ±0.5%

 

 

Current

 

Measurement range:

 0.0 … 20%

Accuracy:

 ± 1%

Logging

Sampling:

 5 readings/sec continuous sampling per channel

Readings:

 User selectable up to 100 readings on 3 phases and neutral simultaneously

Averaging:

 2hr down to 0.5s user selectable

Memory:

 User selectable up to 7MB of shared memory

Recording time:

 User selectable, depends on selected number of readings

Zoom:

 Yes

Autotrend recording

Sampling:

 5 readings/sec continuous sampling per channel

Memory:

 1800 min, max and avg points for each reading

Recording time:

 Up to 450 days

Zoom:

 Up to 12x horizontal zoom

Memory

Screens & data:

 50, shared memory divided between logging, screens and data sets

Notes

¹

 Depending on clamp scaling

²

 Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle

Environmental Specifications

Operating Temperature

 

 0 ºC to +50 ºC

Safety Specifications

Safety

 

 EN61010-1 (2nd edition) pollution degree 2; 1000 V CAT III / 600 V CAT IV ANSI/ISA S82.01

Mechanical & General Specifications

Size

 

 256 x 169 x 64 mm

Weight

 

 2 kg

Battery Life

Rechargeable NiMH pack (installed):

 >7 hours

Battery charging time:

4 hours typical

Shock & Vibration

Shock:

 30 g

Vibration:

 3 g according to MIL-PRF-28800F Class 2

Case

 

 Rugged, shock proof with integrated protective holster, IP51 (drip and dust proof)

Warranty

 

 3 years