Fluke Networks DTX 1200 Cat5, Cat5e, Cat6 Digital LAN Cable Analyzer
Description
The Fluke DTX Series Cable Analyzers were designed with your time in mind. They significantly reduce the time it takes to certify your network when compared with competitors' analyzers. The Fluke DTX testers will test and certify your CAT 6 cable in 12 seconds. Most other testers take over 30 seconds to perform the same test. This translates to 85 extra certifications before lunch! Not only do these analyzers test for problems, they also suggest potential actions to correct the problem, saving even more troubleshooting time.
The DTX 1200 has a maximum testing bandwidth of 350 MHz, allowing all tests to be done in just 12 seconds in full compliance with industry standards.
The DTX 1800 has a maximum testing bandwidth of 900 MHz, which will allow you to test video distribution, Class F, CATV and 10 Gigabit Ethernet cables.
Unit's internal memory stores up to 250 graphical Cat 6 test results or up to 2000 text reports. In addition each unit includes LinkWare software for link to your PC. Software allows you to edit, view, print, and archive your data. You can then export the data to a PDF.
Features
- Increase productivity from day one. Intuitive interface means your techs spend less time in training and more time testing
- Zero to certify in 9 seconds. This unheard-of Cat 6 test speed lets you move from link to link three times faster than with previous testers
- Level IV Accuracy. Get the most accurate test results in the shortest possible time
- 350 MHz frequency range. Prepares you for future applications, such as 10 Gigabit Ethernet, Class F and CATV
- Advanced time-saving diagnostics. Pinpoints the location of a failure and is the only tester that suggests corrective action, saving troubleshooting time
- Record-fast fiber certification. Certifies a pair of fibers in 9 seconds with DTX single mode and multimode fiber modules
- 12-hour battery life. Gives you the power to complete any job.
- Save time managing results. From setup to reporting, LinkWareTCable Test Management Software's simple user interface and time-saving features increase productivity
Specifications
Cable Types Standard Link |
Shielded and unshielded Twisted Pair (STP, FTP, SSTP and UTP) LAN cabling: TIA Category 3, 4, 5, 5E and 6: 100Ω ISO/IEC Class C and D: 100Ω and 120Ω ISO/ IEC Class E, 100W ISO/ IEC Class F, 100Ω Cat 6/ Class E permanent link adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E permanent link Cat 6/Class E channel adapters Plug type and life: shielded and unshielded cable, TIA Cat 3, 4, 5, 5e, and 6 and ISO/IEC Class C, D and E channels |
Test Standards |
TIA Category 3 and 5e per TIA/EIA-568B TIA Category 5 (1000BASE-T) per TIA TSB-95 TIA Category 6 per TIA/EIA-568B.2-1 (Addendum #1 to TIA/EIA-568B.2) ISO/IEC 11801 Class C, D, and E ISO/IEC 11801 Class F (DTX-1800 only) EN 50173 Class C, D, E EN 50173 Class F (DTX-1800 only) ANSI TP-PMD IEEE 802.3 10BASE-T, 100BASE-TX, 1000BASE-T IEEE 802.5 (STP cabling, IBM Type 1, 150Ω ) Token Ring, 4 Mbps and 16 Mbps |
Speed of Autotest |
Full 2-way Autotest of Category 6 Twisted-Pair links in 12 seconds or less |
Supported Tests Parameters |
(The selected test standard determines the test parameters and the frequency range of the tests) Wire Map |
Display |
3.7 in (9.4 cm) diagonal, 240 dots wide by 320 dots high, passive color, transmissive LCD with backlight. |
Input Protection |
Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage. |
Case |
High impact plastic with shock absorbing over-mold |
Dimensions |
Main unit and Smart Remote: 8.5 in x 4.4 in x 2.4 in (21.6 cm x 11.2 cm x 6cm), nominal |
Weight |
2.4 lb (1.1 kg), nominal (without adapter or module) |
Operating Temperature |
32°F to 104°F (0°C to 40°C) |
Storage Temperature |
-4°F to +140°F (-20°C to +60°C) |
Operating relative humidity (% RH without condensation) |
32°F to 95 °F (0°C to 35°C): 0 % to 90 % 95°F to 113°F (35°C to 45°C): 0 % to 70 % |
Vibration |
Random, 2 g, 5 Hz -500 Hz |
Shock |
1 m drop test with and without module and adapter attached |
Safety |
CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2 |
Pollution degree |
Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 “Safety of Information Technology Equipment, 1999” |
Altitude |
Operating: 4000 m; Storage: 12000 m |
EMC |
EN 61326-1 |
Power |
Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh Typical battery life: 12 to 14 hours Charge time (with tester off): 4 hours (below 40 °C) AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ; Output 15 V dc, 1.2 A AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac, 48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output) Memory backup power in main unit: Lithium battery Typical life of lithium battery: 5 years
|
Calibration |
Service center calibration period is 1 year |
Performance Specifications |
Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement performance for cable with a different impedance. |
Baseline accuracy |
The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV as in draft 2nd Edition of IEC 61935-1 over the frequency range supported by the tester. |
Category 6/Class E link test modes (and lower link categories) |
DTX CableAnalyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1 |
Class F link test modes |
DTX-1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935-1. |
Length for Twisted Pair Cabling |
(Length specs do not include the uncertainty of the cable's NVP Value) |
Parameter |
Single-ended Test |
Range |
800 m (2600 ft) – Single-ended Test |
Resolution |
0.1 m or 1 ft – Single-ended Test |
Accuracy |
± (1m + 4%) – Single-ended Test |
Delay Skew |
|
Parameter |
Twisted Pair Cabling |
Range |
0 ns to 100 ns |
Resolution |
1ns |
Accuracy |
± 10 ns |
DC Loop Resistance Test |
|
Parameter |
Twisted Pair Cabling |
Range |
O Ω to 53Ω |
Resolution |
0.1 Ω |
Accuracy |
± (1 Ω + 1%) |
Overload Recovery Time |
Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or prolonged over-voltage. |