LogiMetrics A240/S EMC / TWT Power Amplifier 2 GHz - 4 GHz 10W

Description

The LogiMetrics 3.5″ high A230 series and the 525″ high A240 series of medium power microprocessor based instrumentation and subsystem amplifiers provide the user with proven reliable instrumentation for a wide variety of test and system applications.

The operating modes are selectable via front panel push button controls and the operating mode is displayed on an LED digital display. Additionally, salient power supply voltages, currents and fault indicators can be displayed.

Each amplifier is remote controllable via the standard IEEE-488 GPIB. Each amplifier features complete regulation of the helix, filament, and grid power supplies, thus providing stable operation and long life for the TWTs. The TWT is fully protected against power supply malfunctions such as helix over current.

 

Features

  • Monitor-Digital Display
    • Standby
    • Faults
    • Helix Voltage/Current
    • Collector Voltage
    • Power Out (option 30) in Watts and
    • DBm
  • Mode- Digital Display
    • Power On/Off
    • RF On
  • Controls
    • Power On
    • Power Off
    • RF On
    • RF Off
    • Local Select
  • Ease of Maintenance
  • Designed to meet the safety requirements of IEC-348 and Underwriters laboratory of American Standards
  • Broadband Coverage

LogiMetrics A240/S Applications

EMC Susceptibility Testing

Threat Simulation

Communications

Antenna Patterns Testing

General laboratory Instrumentation

Component Testing

System Preamplifiers

Download Data Sheet
Print
Email

Specifications

Frequency Range (GHz)

2–4 GHz

Min. Pwr Out (Watts)

10 Watts

Min. Sat. Gain (dB)

30 dB

Max NF (dB)

35 dB

Spurious

-40 dBc (-50 dBc available)

In/Out Impedance

50 Ohms

RF Connectors

Frequency

Input

Output

1-18 GHz

Type N

Type N

Location

Front Panel

Front Panel

Prime Power

Switchable 115 or 230 VAC, +-10%, Single Phase, 50-60 Hz, 750 VA max.

Cooling

Internal Air Forced

Air Intake

Rear Panel

Air Exhaust

Rear Panel

Operating Temperature

0-50 deg C (40 deg C @ 10,000 Feet)

Relative Humidity

95% (non condensing)

Operating Altitude

10,000 ft Max.

Non Operating

-20 to 70 deg C

Remote Operation

Standard operating mode control and status monitoring via IEEE-488 GPIB

Dimensions

5.25 x 16.5 x 20.5 in

Weight

38 lbs (17.3 kg)