LogiMetrics A600/EH TWT Microwave Amplifier 2 GHz - 8 GHz 200W
Description
The A600 series of high power, linear broadband microwave amplifiers provide the user with proven reliable instrumentation for a wide variety of test and system applications. Each amplifier features regulation of the helix, filament and grid power supplies, thus providing stable operation and long life for the TWTs.
The TWT is fully protected against power supply malfunctions such as helix overcurrent, the power supply is designed to incorporate depressed collector TWTs as manufactured by several suppliers, allowing for wide flexibility in meeting your needs.
Optionally, the TWTAs can be supplied with complete input and output VSWR protection.
Features
- Monitors –
- Collector Current Voltage
- Helix Current Meter
- Status Indicators
- Power On
- RF Standby/On
- Faults:
- Helix Overcurrent
- VSWR Overload
- Power Supply Thermal Overload
- TWT Thermal Overload
- Air Flow
- Controls
- Power On/Off
- RF Standby/On
- Fault Reset
- Local/Remote
- Ease of Maintenance
- Designed to meet the safety requirements of IEC-348 and UL1419
- Broadband Frequency
LogiMetrics A600 Applications
- EMC Susceptibility Testing
- System Amplifiers
- Communications
- Threat Simulation
- General Laboratory Instrumentation
- Antenna Patterns Testing
- High Power Component Testing
Specifications
Frequency Range (GHz) |
2–8 GHz |
|||
Min. Pwr Out (Watts) |
200 Watts |
|||
Min. Sat. Gain (dB) |
36 dB |
|||
Max NF (dB) |
35 dB |
|||
Spurious |
-40 dBc (-50 dBc available) |
|||
In/Out VSWR |
2.5:1 Maximum |
|||
In/Out Impedance |
50 Ohms |
|||
RF Connectors |
Frequency |
Input |
Output |
|
1-18 GHz |
Type N |
Type N |
||
Location |
Front Panel |
Front Panel |
||
Prime Power |
208 VAC, ±10%, Three Phase, 50/60 Hz, 2.5 kVA maximum |
|||
Cooling |
Internal Air Forced |
|||
Air Intake |
Rear Panel |
|||
Air Exhaust |
Rear Panel |
|||
Operating Temperature |
0-50 deg C (40 deg C @ 10,000 Feet) |
|||
Relative Humidity |
95% (non condensing) |
|||
Operating Altitude |
10,000 ft Max. |
|||
Non Operating |
-20 to 70 deg C |
|||
Remote Operation |
Standard operating mode control and status monitoring via IEEE-488 GPIB |
|||
Dimensions |
14 x 17 x 25 in |
|||
Weight |
175 (79.6 kg) |