Teseq NSG 435 ESD Simulator 16.5 kV

Description

Teseq NSG 435 ESD Simulator 16.5 kV is designed to sit comfortably in the operator’s hand, with current operating conditions constantly displayed and clearly visible.

NSG 435’s microprocessor-based controller and multifunction keypad provide the operator with instant access to its comprehensive range of built-in functions. The LCD panel continuously displays the operating status and all user-selected test parameters.

NSG 435 has its own internal, battery operated high voltage generator. In addition to the pre-programmed, standard IEC pulses, the user can create custom tests using single or repetitive discharges with selectable rates and manual or automatic polarity switching.

Features

  • Programmable discharge voltage 200 V to 16.5 kV
  • Stabilized charging voltage
  • Pre-programmed IEC/EN 61000-4-2 test settings
  • True air-discharge breakdown voltage
  • Compact and lightweight design
Download Data Sheet
Print
Email

Specifications

Parameter Value
Basic set electrostatic discharge simulator, battery pack, battery charger 100 to 240 VAC, discharge network 150 pF/330 Ω, air- and contact-discharge tips, grounding cable, tripod adapter, user manual
Pulse network Network 150 pF/330 Ω as per IEC/EN 61000-4-2 (included)
Range of R/C networks for other standards: R = 0 Ω to 10 kΩ; C = 60 to 500 pF
Discharge voltage Air-discharge: 200 V to 16.5 kV (in 100 V steps)
Contact-discharge: 200 V to 9 kV (in 100 V steps)
Discharge
tips
Ball and point as per IEC
Charging voltage measurement kV, accuracy better than ±5% (stabilized); measurement and display of true air flashover voltage
Discharge detection Indicated by an oval around the kV symbol, also acoustically in the ‘Single’ operating mode (air-discharge only)
Holding time >5 s (charging voltage … ±5%)
Polarity Positive / negative / automatic change
Operating modes Single / repetitive =
pulse counter: 0 to 9999, preselect counter 0 to 9999
Repetition: 0.5/1/5/10/20 or 25 Hz (air); 0.5/1/5 or 10 Hz (contact);
continuous operation
Display LCD panel showing: charging voltage, discharge voltage, polarity, air-/contact-discharge, counter/preselect counter content, soft-key functions, battery monitor
Weight NSG 435 with battery: 1.2 kg (2.6 lbs) approx.
Ambient conditions Operation: +5 to +40°C, 20 to 80 % r.h. (non-condensing), 68 to 106 kPa
Stay informed