Xantrex/Sorensen XFR 300-9 Programmable DC Power Supply 300V 9A 2.8kW
Description
The Xantrex XFR 2.8 kW programmable DC power supply provides clean, reliable power for research, product development, and production test applications. The supplies are ideal for OEM applications where high power and a wide adjustment of output voltage or current are required in a full 19-inch rack package.
The XFR 2.8 kW has excellent thermal management allowing for units to be stacked in rack mounts without any ventilation space required between each unit. The supplies offer high reliability with zero voltage, or “soft switching”, which virtually eliminates switching transients for high efficiency, decreased heat generation, and reduced stress on the switching transistors.
Features
- Zero voltage “Soft Switching”
- Simultaneous front panel display of output voltage and current
- Constant voltage or constant current operation
- Standby mode
- Remote sense with 5 V line loss compensation
- LabVIEW® and LabWindows® drivers
- Over voltage protection
- Over temperature protection
Specifications
Model | XFR 7.5-140 |
XFR 12-100 |
XFR 20-60 |
XFR 35-35 |
XFR 40-30 |
XFR 60-20 |
XFR 100-12 |
XFR 150-8 |
XFR 300-4 |
XFR 600-2 |
Output Ratings: | ||||||||||
Output Voltage | 0-7.5V | 0-12V | 0-20V | 0-35V | 0-40V | 0-60V | 0-100V | 0-150V | 0-300V | 0-600V |
Output Current | 0-140A | 0-100A | 0-60A | 0-35A | 0-30A | 0-20A | 0-12A | 0-8A | 0-4A | 0-2A |
Output Power | 1050W | 1200W | 1200W | 1225W | 1200W | 1200W | 1200W | 1200W | 1200W | 1200W |
Line Regulation: (2) | ||||||||||
Voltage (0.01% of Vmax+2mV) |
2.75mV | 3.2mV | 4mV | 5.5mV | 6mV | 8mV | 12mV | 17mV | 32mV | 62mV |
Current (0.01% of Imax+2mA) |
16mA | 12mA | 8mA | 5.5mA | 5mA | 4mA | 3.2mA | 2.8mA | 2.4mA | 2.2mA |
Load Regulation: (3) | ||||||||||
Voltage (0.02% of Vmax+5mV) |
6.5mV | 7.4mV | 9mV | 12mV | 13mV | 17mV | 27mV | 35mV | 65mV | 125mV |
Current (0.02% of Imax+5mA) |
33mA | 25mA | 17mA | 12mA | 11mA | 9mA | 7.4mA | 6.6mA | 5.8mA | 5.4mA |
Meter Accuracy: | ||||||||||
Voltage (0.5% of Vmax+1 count) |
0.05V | 0.07V | 0.2V | 0.3V | 0.3V | 0.4V | 0.6V | 0.9V | 3V | 4V |
Current (0.5% of Imax+1 count) |
0.8A | 0.6A | 0.4A | 0.3A | 0.3A | 0.2A | 0.07A | 0.05A | 0.03A | 0.02A |
Output Noise & Ripple: (4) | ||||||||||
Voltage rms | 5mv | 5mv | 5mv | 5mv | 5mv | 5mv | 5mv | 7mv | 10mV | 25mV |
Voltage p-p (0-20MHz) | 40mV | 40mV | 60mV | 60mV | 60mV | 60mV | 60mV | 60mV | 80mV | 140mV |
Current rms | 175mA | 100mA | 85mA | 25mA | 25mA | 10mA | 5mA | 3mA | 2mA | 1mA |
Drift (8 hours): (5) | ||||||||||
Voltage (0.05% of Vmax) |
3.8mV | 6mV | 10mV | 17.5mV | 20mV | 30mV | 50mV | 75mV | 150mV | 300mV |
Current (0.05% of Imax) |
70mA | 50mA | 30mA | 17.5mA | 15mA | 10mA | 6mA | 4mA | 2mA | 1mA |
Temperature Coefficient: (6) | ||||||||||
Voltage (0.02% of Vmax/°C) |
1.5mV | 2.4mV | 4mV | 7mV | 8mV | 12mV | 20mV | 30mV | 60mV | 120mV |
Current (0.03% of Imax/°C) |
42mA | 30mA | 18mA | 10.5mA | 9mA | 6mA | 3.6mA | 2.4mA | 1.2mA | 0.6mA |
Program Slew Rate: (7) | ||||||||||
Rise Time | 100ms | 100ms | 100ms | 100ms | 100ms | 100ms | 170ms | 170ms | 170ms | 170ms |
Fall Time | 100ms | 100ms | 100ms | 100ms | 100ms | 100ms | 170ms | 170ms | 170ms | 170ms |
OVP Adjustment Range: | ||||||||||
(5% to 110% of Vmax) | 0.375 – 8.25V |
0.6 – 13.2V |
1 – 22V |
1.75 – 38.5V |
2 – 44V |
3 – 66V |
5 – 110V |
7.5 – 165V |
15 – 330V |
30 – 660V |
Efficiency: (8) | ||||||||||
80% | 82% | 84% | 84% | 84% | 84% | 84% | 87% | 86% | 85% | |
(1) Specifications indicate typical performance at 25°C ±5°C, nominal line input of 120VAC. (2) For input voltage variation over the AC input voltage range, with constant rated load. (3) For 0-100% load variation, with constant nominal line voltage. (4) Measured at full rated output with a resistive load. (5) Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up. (6) Change in output per °C change in ambient temperature, with constant line and load. (7) Measured with stepped 0-10V analog programming source and a resistive load. (8) Typical efficiency at 100 VAC input and rated output power. (9) Derate output current on 6V model by 1.5A/deg C for operating temperatures 35 to 50 deg C. |
||||||||||
RS-232 or GPIB Interface Specifications (with optional interface installed) | ||||||||||
Model | XFR 7.5-140 |
XFR 12-100 |
XFR 20-60 |
XFR 35-35 |
XFR 40-30 |
XFR 60-20 |
XFR 100-12 |
XFR 150-8 |
XFR 300-4 |
XFR 600-2 |
Program Resolution (16 Bit) | ||||||||||
Voltage (mV) | 0.13 | 0.2 | 0.34 | 0.59 | 0.67 | 1.01 | 1.68 | 2.52 | 5.04 | 10.1 |
Current (mA) | 2.35 | 1.68 | 1.01 | 0.59 | 0.5 | 0.34 | 0.2 | 0.13 | 0.07 | 0.03 |
OVP (mV) | 0.13 | 0.2 | 0.34 | 0.59 | 0.67 | 1.01 | 1.68 | 2.52 | 5.04 | 10.1 |
Program Accuracy | ||||||||||
Voltage (mV) (0.2%+10mV) |
25 | 34 | 50 | 80 | 90 | 130 | 210 | 310 | 610 | 1210 |
Current (mA) (0.3%+10mA) |
430 | 310 | 190 | 115 | 100 | 70 | 46 | 34 | 22 | 16 |
OVP (mV) (0.5%+100mV) |
138 | 160 | 200 | 275 | 300 | 400 | 600 | 850 | 1600 | 3100 |
Readback Resolution (16 Bit) | ||||||||||
Voltage (mV) | 0.13 | 0.2 | 0.34 | 0.59 | 0.67 | 1.01 | 1.68 | 2.52 | 5.04 | 10.1 |
Current (mA) | 2.35 | 1.68 | 1.01 | 0.59 | 0.5 | 0.34 | 0.2 | 0.13 | 0.7 | 0.03 |
Readback Accuracy | ||||||||||
Voltage (mV) (0.2%+20mV) |
35 | 44 | 60 | 90 | 100 | 140 | 220 | 320 | 620 | 1220 |
Current (mA) (0.3%+20mA) |
440 | 320 | 200 | 125 | 110 | 80 | 56 | 44 | 32 | 26 |
XFR 1.2kW General Specifications | |
Operational AC Input Voltage | 85-130VAC or 190-264VAC, 1 phase (17 @ 120VAC; 8.8A @ 230VAC typical), 47-63Hz |
Switching Frequency | Nominal 78kHz (156kHz output ripple) |
Time Delay | 7s maximum from power on until output stable |
Voltage Mode Transient Response Time | 3ms for output voltage to recover within 0.5% of its previous level after a step change in load current of up to 10% to 90% of rated output |
Maximum Voltage Differential | ±600VDC from output to safety ground |
Remote Start/Stop and Interlock | TTL-compatible input, selectable logic |
Remote Analog Programming | Voltage and current programming inputs (source must be isolated): 0-5k, 0-10k resistances; 0-5V (default), 0-10V voltage sources |
Remote Analog Monitoring | Voltage/ current monitor outputs 0-5V, 01-10V ranges for 0-100% of output |
Remote Programming and Monitoring Accuracy | <1% of full scale output for the default range |
Maximum Remote Sense Line Drop Compensation | 5V/line (Line drop is subtracted from total voltage available at supply output) |
Operating Temp. Range | 0 to 50°C |
Storage Temperature Range | –40 to 85°C |
Humidity Range | 0 to 80% RH, non-condensing |
Front Panel Voltage and Current Control | 10-turn voltage and current potentiometers |
Front Panel Voltage Control Resolution | 0.02% of maximum voltage |
AC Input Connector Type | 3-Terminal, 34A/250V, wire clamp connector with strain relief cover |
Main Output Connector | 7.5 to 40V models: nickel-plated copper bus bars with bus bar cover; 60V to 600V models: 4-terminal wire clamp connector with strain relief |
Weight | Approximately 8.2kg (18 lb) |
Approvals | CE-marked, units meet IEC 1010-1 safety standard, and EN50081-2 and EN50082-1 EMC standards. Additional standards: CSA C22.2 No. 1010.1, UL 3101, and FCC, part 15, class A EMI standard |
XFR 1.2kW Options | |
GPIB-XFR | GPIB Interface Card (16 Bit) |
RS-232-XFR | RS-232 Interface Card (16 Bit) |
ISOL-XFR | Isolated Interface Card provides isolated analog control and readback of output voltage and current |
M13 | Locking Bushings on front panel controls |
Specifications(1) for the XFR 2.8kW Series (Specifications are subject to change without notice) | |||||||||
Model | XFR 7.5-300 |
XFR 12-220 |
XFR 20-130 |
XFR 40-70 |
XFR 60-46 |
XFR 100-28 |
XFR 150-18 |
XFR 300-9 |
XFR 600-4 |
Output Ratings: | |||||||||
Output Voltage | 0-7.5V | 0-12V | 0-20V | 0-40V | 0-60V | 0-100V | 0-150V | 0-300V | 0-600V |
Output Current | 0-300A | 0-220A | 0-130A | 0-70A | 0-46A | 0-28A | 0-18A | 0-9A | 0-4A |
Output Power | 2250W | 2640W | 2600W | 2800W | 2760W | 2800W | 2700W | 2700W | 2400W |
Line Regulation: (2) | |||||||||
Voltage (0.01% of Vmax + 2mV) |
2.75mV | 3.2mV | 4mV | 6mV | 8mV | 12mV | 17mV | 32mV | 62mV |
Current (0.01% of Imax + 2mA) |
32mA | 24mA | 15mA | 9mA | 6.6mA | 4.8mA | 3.8mA | 2.9mA | 2.4mA |
Load Regulation: (3) | |||||||||
Voltage (0.02% of Vmax + 5mV) |
6.5mV | 7.4mV | 9mV | 13mV | 17mV | 27mV | 35mV | 65mV | 125mV |
Current (0.02% of Imax + 5mA) |
65mA | 49mA | 31mA | 19mA | 14.2mA | 10.6mA | 8.6mA | 6.8mA | 5.8mA |
Meter Accuracy: | |||||||||
Voltage (0.5% of Vmax + 1 count) |
0.05V | 0.07V | 0.2V | 0.3V | 0.4V | 0.6V | 0.9V | 3V | 4V |
Current (0.5% of Imax + 1 count) |
3A | 2A | 0.8A | 0.5A | 0.3A | 0.2A | 0.1A | 0.06A | 0.03A |
Output Noise & Ripple: | |||||||||
Voltage rms | 4mV | 5mV | 6mV | 6mV | 6mV | 12mV | 15mV | 20mV | 35mV |
Voltage p-p (0-20MHz) |
50mV | 50mV | 60mV | 60mV | 60mV | 75mV | 100mV | 120mV | 200mV |
Current rms | 400mA | 200mA | 100mA | 50mA | 30mA | 10mA | 5mA | 5mA | 0.7mA |
Drift (8 hours): (4) | |||||||||
Voltage (0.05% of Vmax) |
3.8mV | 6mV | 10mV | 20mV | 30mV | 50mV | 75mV | 150mV | 300mV |
Current (0.1% of Imax) |
300mA | 220mA | 130mA | 70mA | 46mA | 28mA | 18mA | 9mA | 4mA |
Temperature Coefficient: (5) | |||||||||
Voltage (0.02% of Vmax/°C) |
1.5mV | 2.4mV | 4mV | 8mV | 12mV | 20mV | 30mV | 60mV | 120mV |
Current (0.03% of Imax/°C) |
90mA | 70mA | 40mA | 25mA | 15mA | 9mA | 5.5mA | 2.7mA | 1.2mA |
Program Slew Rate: (6) | |||||||||
Rise Time | 100ms | 100ms | 100ms | 100ms | 100ms | 170ms | 170ms | 170ms | 170ms |
Fall Time | 100ms | 100ms | 100ms | 100ms | 100ms | 170ms | 170ms | 170ms | 170ms |
OVP Adjustment Range: | |||||||||
(5% to 110% of Vmax) | 0.375 – 8.25V |
0.6 – 13.2V |
1 – 22V |
2 – 44V |
3 – 66V |
5 – 110V |
7.5 – 165V |
15 – 330V |
30 – 660V |
Efficiency: (7) | 81% | 84% | 87% | 86% | 88% | 89% | 90% | 90% | 90% |
(1) Specifications indicate typical performance at 25°C ± 5°C, nominal line input of 208VAC. (2) For input voltage variation over the AC input voltage range, with constant rated load. (3) For 0-100% load variation, with constant nominal line voltage. (4) Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up. (5) Change in output per °C change in ambient temperature, with constant line and load. (6) Measured at full rated ouput with a resistive load. (7) Typical efficiency at 200 VAC input and rated output power. |
|||||||||
RS-232 or GPIB Interface Specifications (with optional interface installed) | |||||||||
Model | XFR 7.5-300 |
XFR 12-220 |
XFR 20-130 |
XFR 40-70 |
XFR 60-46 |
XFR 100-28 |
XFR 150-18 |
XFR 300-9 |
XFR 600-4 |
Program Resolution (16 Bit) | |||||||||
Voltage (mV) | 0.13 | 0.2 | 0.34 | 0.67 | 1.01 | 1.68 | 2.52 | 5.04 | 10.1 |
Current (mA) | 5.04 | 3.69 | 2.18 | 1.17 | 0.77 | 0.47 | 0.3 | 0.15 | 0.07 |
OVP (mV) | 0.13 | 0.2 | 0.34 | 0.67 | 1.01 | 1.68 | 2.52 | 5.04 | 10.1 |
Program Accuracy | |||||||||
Voltage (mV) (0.2%+10mV) | 25 | 34 | 50 | 90 | 130 | 210 | 310 | 610 | 1210 |
Current (mA) (0.3%+10mA) | 910 | 670 | 400 | 220 | 148 | 94 | 64 | 37 | 22 |
OVP (mV) (0.5%+100mV) | 138 | 160 | 200 | 300 | 400 | 600 | 850 | 1600 | 3100 |
Readback Resolution (16 Bit) | |||||||||
Voltage (mV) | 0.13 | 0.2 | 0.34 | 0.67 | 1.01 | 1.68 | 2.52 | 5.04 | 10.1 |
Current (mA) | 5.04 | 3.69 | 2.18 | 1.17 | 0.77 | 0.47 | 0.3 | 0.15 | 0.07 |
Readback Accuracy | |||||||||
Voltage (mV) (0.2%+20mV) | 35 | 44 | 60 | 100 | 140 | 220 | 320 | 620 | 1220 |
Current (mA) (0.3%+20mA) | 920 | 680 | 410 | 230 | 158 | 104 | 74 | 47 | 32 |