Amplifier Research FL7040 Electric Field Probe 2 MHz – 40 GHz 1000V/m

Description

Amplifier Research FL7040 Electric Field Laser Probe 2 MHz – 40 GHz 1000V/m is a smart, fast, extremely accurate electric field probe that contains an internal microprocessor to provide linearization, temperature compensation, control, and communication functions. Noise reduction and temperature compensation allow accurate measurements down to 2 V/m without zero adjustment. Microprocessor based linearization technology provides a 54-dB dynamic range. When rotated about its critical angle mount, the probe provides typical isotropic response of ±1.5 dB to 40 GHz.

The FL7040 is laser powered to allow for continuous operation without recharging or battery replacement.

Correction factors are provided with the probe. These factors can be loaded into the Model FM7004 Field Monitor (sold separately) to automatically correct the probe readings at user-specified frequencies. When correction factors are applied, the true accuracy of the probe can be realized.

The FL7040 communicates through glass fiber optic cables, up to 100 meters long, to the FI7000 interface. X, Y, Z, and isotropic readings can be returned through an FI7000 in 20 msec.

Features

  • Broad frequency range
  • Contains an internal microprocessor that enables them to “think” for themselves and adapt to their environment
  • Provides optimal linearization, temperature compensation, control and communication functions
  • Because they’re laser powered, you never have to change or replace batteries
  • Ruggedized antenna cones and fiber optic cables provide unequalled reliability
Download Data Sheet
Print
Email

Specifications

Amplitude Accuracy (field aligned with sensor axes)
Without correction factors applied ±1.0 dB @ 10 MHz
With correction factors applied Typical expanded measurement uncertainty (95% confidence interval)
0.8 dB,2 MHz–1 GHz
1.4 dB, 1 GHz–40 GHz
Response Time/Sampling Rate (through FI7000) 20 msec/up to 50 samples per second, USB and GPIB only
Isotropic Deviation (measured at the critical angle) ± 0.5 dB @ 10 MHz
± 1.5 dB, 2 MHz–40 GHz (typical)
Operating Range 2–1000 V/m
Linearity, 2 to 1000 V/m ± 0.5 dB
Temperature Stability ± 0.5 dB over operating temperature range
Damage Level 1200 V/m CW
Ranges Single continuous range
Data returned from probe X, Y, Z axes, and composite
Power Requirements Laser powered from FI7000 interface
Dimensions Approx. 278 x 65 x 65 mm
Probe Head Diameter 65mm
Weight 150g approx.
Operating Temperature Range 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensing
Fiber Optic Connectors Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.