Amplifier Research MT06000 RF Radiated Immunity System 80MHz – 6GHz
Description
Amplifier Research MT06000 (Multistar™ Multi-tone tester) is a state-of-the-art system designed to test RF Radiated Immunity faster than ever before possible. By testing multiple frequencies (tones) at once, test times can be reduced by a factor equivalent to the number of tones selected. The number of tones is only limited by the signal generator bandwidth (150 MHz) and the size of the amplifier used with the system.
The MT06000 contains all the instruments needed to perform radiated immunity testing for IEC 61000-4-3 specification except the required amplifiers, antennas and directional couplers. Amplifiers can be sized and selected based on your required field levels and testing needs.
Up to 4 RF amplifiers and directional couplers can be controlled and monitored and power can be delivered to up to 4 antennas to generate the desired fields. The system contains a vector signal generator, a vector signal analyzer, a RF pre-amplifier, a RF field probe and monitor, an RF switch matrix, and automated radiated immunity test software.
Everything is contained in a single housing, which eliminates setup issues. The software includes automated routines to calibrate the field and maximize the speed of test (most tones possible) while still meeting the Linearity and Harmonics requirements of the specification.
In the event of a EUT failure, margin investigation (thresholding) and traditional single tone testing can be performed causing a slowing of the test only in the areas of concern. This system has the versatility needed for every test laboratory and equipment manufacturer while adding the benefit of reduced test times and greater throughput.
Features
Complete Testing Solutions to the following standards
- EN/IEC 61000-4-3
- EN/IEC 60601-1-2
- EN 50130-4
- EN 61000-6-1/2
- EN 55024
Specifications
Internal Test Specifications |
|
IEC/EN 60601-1-2 IEC/EN 50130-4 IEC/EN 61326 IEC/EN 61000-6-1 IEC/EN 61000-6-2 CISPR 24/EN 55024 |
IEC 61000-4-3 procedure and levels |
Vector Signal Generator Specifications |
|
Frequency range Resolution |
80 < Hz to 6.6 GHz < 4 Hz |
Power Out |
+10 dBm |
Modulation |
AM, FM, Pulse, Phase |
Bandwidth |
150 MHz |
Hardware Platform |
PXIe |
Vector Signal Analyzer Specifications |
|
Frequency Range Resolution |
10 MHz – 6.6 GHz 533 nHz |
Dynamic Range |
80 dB |
Bandwidth |
50 MHz |
Hardware Platform |
PXIe |
RF Preamplifier Specifications |
|
Frequency Range |
50 MHz – 8 GHz |
Gain |
26 dB |
Hardware Platform |
PXIe |
Field Monitor/Probe Spec |
|
Channels |
4 |
Probe |
1 |
Type |
Isotropic, Laser powered |
Frequency |
100 kHz – 6 GHz |
Range |
0.5 – 800 V/m |
Connections |
|
RF signal input |
2 SMA Male (rear) For optional signal generators |
RF Signal Out |
4 SMA Male (rear) to RF amplifiers |
High power RF in |
4- Type N Male (rear) from RF amplifiers |
High power RF out |
4 Type N male (rear) to antennas/loads |
Monitor port In |
4- SMA Male (rear) 4 for forward power |
Control PC |
|
Computer |
Intel Core 2 Duo, 2.53 GHz |
Operating system |
Windows 7 |
RAM |
4 GB DDR2 |
Hardware Platform |
PXIe |
General |
|
Power |
115/230 VAC 50/60 Hz, single phase 16A |
Breaker |
2 pole, 20A |
Cooling |
active cooling, air ventilation |
Environmental conditions |
10°C – 40°C |
Dimensions |
50.3 x 47.2 x 61 cm, 19.8 x 18.6 x 24 in |
Weight |
22.7 kg (50.0 lb) |
Accessories |
|
DAQ Module (AR P/N 10025318) (NIUSB-6212) |
Data acquisition module is used to collect data, identify user defined failures, report user defined error messages, and reset EUT after failure |
Low Pass Filter, 80MHz-1GHz |
Absorptive filter used to remove harmonics |
Low Pass Filter, 80MHz-4.2GHz |
Absorptive filter used to remove harmonics |
Low Pass Filter, 80MHz-6GHz |
Absorptive filter used to remove harmonics |