Anritsu MS2711D Handheld Spectrum Analyzer 100 kHz - 3 GHz
Description
Covering the 100 kHz to 3.0 GHz frequency range, with a built in standard pre-amplifier, the MS2711D handheld spectrum analyzer is the proven solution for installing, provisioning, maintaining and troubleshooting wireless systems and RF frequency spectrum interference issues. This portable spectrum analyzer features a built-in standard preamplifier in a compact, handheld design that can go “anywhere, anytime” with no backpack required. Ideal for field environments and applications that require mobility, such as site surveys and on-site system testing.
The Anritsu Spectrum Master is designed for monitoring, measuring, and analyzing signal environments. Typical measurements include: in-band interference, transmit spectrum analysis, antenna isolation and cell area interference. A full range of marker capabilities such as peak, center and delta functions are provided for faster, more comprehensive measurement of displayed signals. Multiple limit lines are available for creating quick, simple pass/fail measurements. A menu option provides for an audible beep when the limit value is exceeded.
Features
- Wide Dynamic Range
- Built-in Preamplifier
- Built-in Tracking Generator Option
- Dynamic Attenuation
- One-Button Measurements
- Trace Averaging
- 50O to 75O Adaptable Interface
- Multilingual User Interface
- Quick Zoom-in, Zoom-out Display
- Reference Level Offset
Specifications
Frequency Range |
100 kHz to 3.0 GHz (tunable to 9 kHz) |
|
Frequency Reference |
Aging |
+ 1 ppm/yr |
Accuracy |
+ 1 ppm |
|
Frequency Span |
10 Hz to 2.99 GHz in 1,2,5 step selections in auto mode, plus zero span |
|
Sweep Time |
1.1 s full span; 50s to 20s, selectable in zero span |
|
SSB Phase Noise |
–75 dBc/Hz, 30 kHz offset @ 1 GHz |
|
Spurious Responses |
Input Related |
< 45 dBc |
Spurious |
Residual Responses |
90 dBm, 10 kHz RBW, pre-amp on |
Resolution Bandwidths |
Selections |
10 Hz to 1MHz in 1-3 sequence |
Accuracy |
± 5% typical |
|
Selectivity |
Video Bandwidth |
5% 3 Hz to 1 MHz in 1-3 sequence |
Amplitude |
Measurement Range |
+20 to –135 dBm +43 dBm, peak, without damage 50 VDC |
Displayed Average Noise Level |
-135 dBm 10 MHz typical with preamplifier on |
|
-115 dBm typical <10 MHz (input terminated, 0 dB attenuation, RMs detection, 100 Hz RBW with preamplifier on |
||
Dynamic Range |
> 65 dB |
|
Total Level Accuracy |
1.5 dBm max (1 dBm typical) |
|
>10 MHz to 3 GHz 2 dBm typical |
||
<10 MHz for input signal levels –60 dBm (excludes input VSWR mismatch) |
||
Scale Mode |
dBm, dBV, dBmV, dBμV |
|
Display Range |
2 to 15 dB/div in 1 dB steps. |
|
Ten divisions displayed |
||
Attenuator |
Range |
0 to 51 dB, selected manually or automatically coupled to the reference level |
Resolution |
1 dB steps |
|
Display |
Type |
Monochrome LCD (with backlit capability) |
Resolution |
640 x 480 |
|
Marker Modes |
6 Markers; standard, delta, marker to peak and marker to center |
|
Memory |
Trace Storage |
200 stored traces |
Setup Storage |
10 test setups |
|
Displayed Traces |
2 |
|
Inputs |
RF Input |
50-Ohms |
Connector |
Type N Female |
|
RF Input VSWR |
2.0:1 |
|
RS-232 Interface |
Type |
Null modem |
Baud Rate |
9600,19.2k, 38.4k, 56k, 115.2k Baud |
|
Printer Interface |
Drivers |
Epson ESC/P |
Epson ESC/P RAST |
||
Epson ESC/P2 |
||
HP PCL3 |
||
General Characteristics |
Dimensions |
10.0 in. x 7.0 in. x 2.4 in. |
25.4 cm x 17.8 cm x 6.1 cm |
||
Weight |
4.9 lbs (2.2 kg) includes battery |
|
Power Requirement |
Battery Operation (standard) |
NiMH battery |
AC/DC Operation (optional via external DC input) |
+ 12.5 to +15 Vdc, 1100 mA max |
|
Environmental Temperature |
Operating |
-10 to +50°C, humidity 85% or less |
Non-operating |
–20 to +75°C |
|
Electromagnetic Compatibility |
Complies with European community requirements for CE marking |
|
Safety |
Conforms with EN 61010-1 for class 1 portable equipment |