AWT Global PIM S1L TETRA & UHF PIM Analyzers
Description
Passive Intermodulation (PIM) is an unwanted mixing effect caused by non-linearity of passive components in the RF path of telecommunication systems. PIM diverts signal energy to other frequencies (spurious signals). This can generate interfering signals that may fall into receiving bands causing serious degradation of system performance. PIM S1L TETRA & UHF PIM testers are ideal for component testing in the laboratory and quality assurance and they are also valuable field tools, providing vital test results in TETRA & UHF networks. The specifications and measurement accuracy of our PIM analyzers are exceptional and deliver reliable results. AWT Global’s PIM S1L TETRA & UHF analyzers are very easy to operate; just the touch of a button to start any predefined test. When public safety officers assign their staff to critical missions, they rely on the performance of their TETRA & UHF networks. Communication and data transmission must not experience any PIM distortion. As such, low PIM components and installations are required. PIM S1L TETRA & UHF helps to establish highest quality networks.
Features
- Test Modes: Diagnostic, Analyzer with Graphs, Sweep Mode, Distance to PIM, Distance to Fault
- Very high PIM sensitivity: -175 dBc @ 2x 43 dBm carriers
- Output power variable from 15dBm to 44dBm
- Fully compliant to PIM Specification IEC 62037
- Measures intermodulation products IM3, IM5 IM7, IM9, IM11 and IM13
- PIM over Time Graph and Rx Sweep Mode
- Maxhold, Minhold, Delta PIM feature
- Data recording: CSV, PDF, Screenshot (BMP)
- Single Carrier mode for insertion loss measurements
Specifications
Model Number |
Technologies / Type |
Tx Frequency (MHz) |
Rx Frequency (MHz) |
|
PS1L-400 |
TETRA |
390 ~ 400 |
380 ~ 385 |
|
PS1L-400E |
E-TETRA |
420 ~ 430 |
410 ~ 412 |
|
PS1L-UHF |
UHF |
Contact factory for other frequency combinations. |
||
Accessories |
||||
POPT1 |
VSWR / DTP (Distance to PIM) / DTF (Distance to Fault) Option |
|||
PACC2 |
Accessory Kit: (2) low PIM cables 3m / 10ft, (1) low PIM cable 1m / 3ft, low PIM load 50W / 10W, adapters, torque wrench with hard carry case |
|||
PLOAD1 |
PIM Load 100W, PIM: < -165 dBc, DIN 7/16(f) |
|||
PLOAD2 |
PIM Load: 50W / 10 W (30 mins / permanent), PIM: < -165 dBc, DIN7/16 (f) – DIN 7/16 (m) |
|||
PIMGEN |
PIM Source: Generator with preset PIM value. Quick indication of system functionality. Ideal for test and training. |
|||
PCAB3M |
Low PIM Cable 3M, DIN(m) – DIN(m) |
|||
Transmitter |
||||
Carrier Power |
+15 to +44 dBm (46 dBm optional) |
|||
Power Accuracy |
+/- 0.35 dB |
|||
Frequency Accuracy |
200 ppm |
|||
Reverse Pwr. Protection |
+43 dBm for 5 sec |
|||
Receiver |
||||
Reverse IM @ 2x43dBm |
-122 dBm / -165 dBc typ. |
|||
Noise Floor |
-132 dBm |
|||
Dynamic Range(typical) |
> 96 dB (ref: -90 dBm) |
|||
Reverse Power Protection |
+43 dBm for 5 sec |
|||
Operational Input Power |
-45 dBm RMS |
|||
Max Input Power |
-10 dBm |
|||
Measurement Accuracy |
+/- 2 dB @ 2 x 43 dBm |
|||
Distance to PIM / Distance to VSWR (Option) |
||||
DTP Accuracy |
0.9 m typ. |
|||
DTF Accuracy (VSWR) |
0.9 m |
|||
Cable Types |
Built-in list of cables |
|||
Dimensions / Weight / Environment / Electrical |
||||
Dimensions |
2 Modules |
|||
Weight |
23.5 kg (51.6 lb) + 23.6 kg (51.8 lb) |
|||
Temperature |
0 °C to +45 °C |
|||
Humidity |
85%, RH (non condensing) |
|||
Protection |
IP20 |
|||
AC Power |
100 to 240V 50/60 Hz |
|||
Power Consumption |
1100 Watts (VA) |