California Instruments - 2001RP 2000 VA Single-Phase AC Power Source
Description
The 2001RP is a 2000 VA programmable, single-phase AC source 16 Hz to 5000 Hz frequency output. It is a small, lightweight source of AC power for applications that require variable voltage and frequency at power levels up to 2000 VA. 103 – 127 V or 187 – 253 V, 47 – 440 Hz input. It has dual LCD readouts for programmed settings of voltage, current limit and frequency. It is equipped with over current, over temperature, and over voltage protection.
Features
- 16 Hz to 5000 Hz
- Dual output voltage ranges, 0-300 or 150 VAC
- Full power with up to 3.3:1 crest factor loads
- Standard Current measurement
- Optional measurements for Peak Current, Voltage, Real Power, Apparent Power, Power Factor
- Simple Front Panel and Rear panel Connections
- Optional GPIB and RS-232C interfaces
- Made in USA
- CE Mark
Specifications
Controller |
Type |
Programmable |
Controls |
Digital Encoders |
|
Readouts |
dual 4 digit LCD's |
|
Non Volatile Setups |
8 (with –OP1 option) |
|
Output |
Phases |
1 |
AC Power |
2000VA |
|
Load Connection Floating Neutral |
Rear panel terminal block |
|
Output Voltage |
High Range / Low Range |
0-300 / 0-150V (L-N) |
Accuracy |
± 0.1 %FS @ 16 Hz – 100 Hz |
|
Accuracy |
± 0.2 %FS @ 100 Hz – 5000 Hz |
|
Resolution |
0.1 V |
|
Line & Load Regulation High V Range |
± 0.5 %FS |
|
Line & Load Regulation Low V Range |
± 1 %FS |
|
Load Regulation 10 % Line Change |
± 0.1 %FS |
|
T.H.D |
0.5 typical % @ 16 Hz – 5000 Hz |
|
Output Noise |
< 0.1 V typical |
|
Output Frequency |
Range |
16 – 5000 Hz |
Accuracy |
± 0.02% |
|
Resolution below 100 Hz |
0.01Hz |
|
Resolution above 100 Hz |
1 Hz |
|
Output Current |
Steady State Current High V Range |
6.7 A rms |
Steady State Current Low V Range |
13.4 A rms |
|
Peak Current High V Range |
22.2 A peak |
|
Peak Current Low V Range |
44.5 A peak |
|
Protection |
Current Limit Mode |
Programmable trip level: Output trips off |
(Output shut off) Resolution |
0.1 A rms |
|
Over Temperature |
Output shut off |
|
Over Voltage |
Output shut off |
|
Input |
Line Voltage 2 wire + GND |
103-127 V rms Maximum operating range 187-253 V rms |
Line Current (fused) |
< 30 A rms |
|
Line Frequency |
47 – 440 Hz |
|
Holdup Time |
10 ms |
|
Power Factor |
> 0.95 typical |
|
Isolation Input/output to Chassis |
1350 V / 2200 V |