California Instruments 2253i/iX Precision Prog. AC Source 2250 VA

Description

The Compact iX Series represents a new generation of AC/DC power sources that address the increasing demands on test equipment to perform additional functions at a lower cost. By combining a flexible AC/DC power source with a high performance power analyzer, the Compact iX Series is capable of handling complex applications that have traditionally required multiple systems.

The sleek integrated approach of the Compact iX Series avoids cable clutter that is commonly found in test systems. All connections are made internally and the need for digital multimeters, power harmonics analyzers, and current shunts or clamps is eliminated.

Since many components in the Compact iX Series are shared between the AC/DC source and the power analyzer, the total cost of the integrated system is less than the typical cost of a multiple unit system.

For less demanding applications, the Compact i Series provide similar output and transient capabilities as the Compact iX Series, as well as basic power measurements.

 

Features

  • 750 VA to 2250 VA of AC Output Power
  • Combines AC/DC source and power analyzer
  • Harmonic analysis of Voltage and Current
  • AC, DC and AC+DC Output Modes
  • Multiple Chassis Configurations
  • Powerful output transient generation
  • High Crest Factor Capability
  • Arbitrary waveform generation
  • Single and Three Phase models available
Download Data Sheet
Print
Email

Specifications

Input

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Voltage

115Vrms +/- 10% or 
230Vrms +/- 10%

115Vrms +/- 10% or 
230Vrms +/- 10%

115Vrms – 230Vrms +/- 10% (Universal Input) – (Output rated 1500 VA @ 115 V input. 115V-180V input derated linearly 1500 VA – 2250 VA)

Frequency

47 – 63 Hz

47 – 63 Hz

47 – 63 Hz

Current

<8.5 Arms @ 115 V 
<4.4 Arms @ 230 V

<17 Arms @ 115 V 
<8.8 Arms @ 230 V

<20 Arms @ 115 V 
<15 Arms @ 230 V

PF

0.97 (typical @ full load)

0.97 (typical @ full load)

0.98 (typical @ full load)

Efficiency

80%

80%

77%

AC Output

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Voltage

Hi : 0 – 300Vrms 
Low : 0 – 150Vrms

Hi : 0 – 300Vrms 
Low : 0 – 150Vrms

Hi : 0 – 300Vrms 
Low : 0 – 150Vrms

Max. Current

Hi : 3.25Arms 
Low : 6.5Arms

Hi : 6.5Arms 
Low : 13Arms

Hi : 3.25Arms (per phase) 
Low : 6.5Arms (per phase)

Peak Current

Hi : 10 A Peak
Low : 20 A Peak

Hi : 20 A Peak 
Low : 40 A Peak

Hi : 10 A Peak (per phase) 
Low : 20 A Peak (per phase)

AC Power

750VA

1500VA

750VA (per phase)

Distortion

< 1% THD

< 1% THD

< 1% THD

DC Output

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Voltage

Hi : 0 – 400Vdc 
Low : 0 – 200Vdc

Hi :0 – 400Vdc 
Low : 0 – 200Vdc

Hi : 0 – 400Vdc 
Low : 0 – 200Vdc

Max Current

Hi : 1.63Adc 
Low : 1.63Adc

Hi : 3.25Adc 
Low : 1.63Adc

Hi : 1.63Adc (per phase) 
Low : 3.25Adc (per phase)

High Range

500W

1000W

500W (per output)

Low Range

250W

250W

500W (per output)

Voltage Accuracy/Programming Resolution (AC/DC)

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Accuracy(ALC Mode ON)

0.1% FS (from 5V to FS)

0.1% FS (from 5V to FS)

0.1% FS (from 5V to FS)

Programming Resolution

0.1V

0.1V

0.1V

Frequency

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Range

16 – 1000Hz

16 – 1000Hz

16 – 1000Hz

Resolution

0.01 Hz (16 – 81.91 Hz), 
0.1 Hz (82.0 – 819.1 Hz) 
1 Hz (820– 1000 Hz)

0.01 Hz (16 – 81.91 Hz), 
0.1 Hz (82.0 – 819.1 Hz) 
1 Hz (820– 1000 Hz)

0.01 Hz (16 – 81.91 Hz), 
0.1 Hz (82.0 – 819.1 Hz) 
1 Hz (820– 1000 Hz)

Accuracy

0.025%

0.025%

0.025%

Measurements

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Voltage Accuracy

V: 0.1% FS

V: 0.1% FS

V: 0.1% FS

Current Accuracy

C: 0.5% FS

C: 0.5% FS

C: 0.5% FS

Mechanical Specifications

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

Dimensions

H: 3.5“ (89mm) 
W: 19” (483mm) 
D: 23“ (584mm)

H: 3.5“ (89mm) 
W: 19” (483mm) 
D: 23“ (584mm)

H: 5.25“ (133mm) 
W: 19” (483mm) 
D: 23“ (584mm)

Weight

 

 

 

Operating Temperature

 

 

 

Interfaces

Model

751i/iX 
(1 Phase Output)

1501i/iX 
(1 Phase Output)

2253i/iX 
(1 or 3 Phase Output)

USB

Standard

Standard

Standard

GPIB

Option (i) Std (iX)

Option (i) Std (iX)

Option (I) Std (IX)

LAN (LXI Ethernet)

Option (iX)

Option (iX)

Option (IX)

RS232

N/A

N/A

Standard

Note: Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted; specifications are per phase for a sine wave with a resistive load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifications are valid under balanced load conditions only.