California Instruments 801RP Series AC Power Source 800 VA
Description
The California Instruments 801RP AC Power Source is designed with both European and US outlet sockets to connect the load making it suitable for a wide variety of applications. This AC Power Source can be used throughout the globe with its universal input and provides a convenient source of variable utility power for testing domestic and commercial equipment.
All common line voltage and frequency combinations are covered. Its high frequency range makes the California Instruments 801RP AC Power Source perfect for commercial and defense avionics applications and its high peak current capability allows it to drive non-linear loads.
Features
- Compact AC Power
- Portable Power, Low Cost
- Easy to Use Controls
- Simple Front Panel Operation
- Ideal for a Wide Variety of Test Applications and Product Evaluation
- Ideal for Commercial and Defense Avionics Applications
- Remote Control Option
- Current Measurement Function Eliminates the Need for an External Current Shunt or Transformer
- Load Current of the Unit Under Test can be read directly on the large LCD display
Specifications
Controller |
Type |
Programmable |
Controls |
Digital Encoders |
|
Readouts |
dual 4 digit LCD's |
|
Non Volatile Setups |
8 (with -IF option) |
|
Output |
Phases |
1 |
AC Power |
800VA |
|
Load Connection Floating Neutral |
Rear panel terminal block |
|
Output Voltage |
High Range / Low Range |
0-270 / 0-135 V (L-N) |
Accuracy |
± 1 %FS @ 50/60 Hz |
|
Accuracy |
± 2 %FS @ 400 Hz |
|
Resolution |
0.1 V |
|
Line & Load Regulation High V Range |
± 0.5 %FS |
|
Line & Load Regulation Low V Range |
± 1 %FS |
|
Load Regulation 10 % Line Change |
± 0.1 %FS |
|
T.H.D |
0.5 typical % @ 50/60 Hz |
|
Output Noise |
< 0.1 V typical |
|
Output Frequency |
Range |
16 – 500Hz |
Accuracy |
± 0.02% |
|
Resolution below 100 Hz |
0.1Hz |
|
Resolution above 100 Hz |
1 Hz |
|
Output Current |
Steady State Current High V Range |
3.0 A rms |
Steady State Current Low V Range |
6.0 A rms |
|
Peak Current High V Range |
13.8 A peak |
|
Peak Current Low V Range |
27.6 A peak |
|
Protection |
Current Limit Mode |
Programmable trip level: Output trips off |
(Output shut off) Resolution |
0.1 A rms |
|
Over Temperature |
Output shut off |
|
Over Voltage |
Output shut off |
|
Input |
Line Voltage 2 wire + GND |
100-240 V rms Maximum operating range 85 – 265 V rms |
Line Current (fused) |
< 15 A rms |
|
Line Frequency |
47 – 63 Hz |
|
Holdup Time |
20 ms |
|
Power Factor |
> 0.95 typical |
|
Isolation Input/output to Chassis |
1350 V / 2200 V |