California Instruments 801RP Series AC Power Source 800 VA

Description

The California Instruments 801RP AC Power Source is designed with both European and US outlet sockets to connect the load making it suitable for a wide variety of applications. This AC Power Source can be used throughout the globe with its universal input and provides a convenient source of variable utility power for testing domestic and commercial equipment.

All common line voltage and frequency combinations are covered. Its high frequency range makes the California Instruments 801RP AC Power Source perfect for commercial and defense avionics applications and its high peak current capability allows it to drive non-linear loads.

 

Features

  • Compact AC Power
  • Portable Power, Low Cost
  • Easy to Use Controls
  • Simple Front Panel Operation
  • Ideal for a Wide Variety of Test Applications and Product Evaluation
  • Ideal for Commercial and Defense Avionics Applications
  • Remote Control Option
  • Current Measurement Function Eliminates the Need for an External Current Shunt or Transformer
  • Load Current of the Unit Under Test can be read directly on the large LCD display
Download Data Sheet
Print
Email

Specifications

Controller

Type

Programmable

Controls

Digital Encoders

Readouts

dual 4 digit LCD's

Non Volatile Setups

8 (with -IF option)

Output

Phases

1

AC Power

800VA

Load Connection Floating Neutral

Rear panel terminal block

Output Voltage

High Range /  Low Range

0-270 / 0-135 V (L-N)

Accuracy

± 1 %FS @ 50/60 Hz

Accuracy

± 2 %FS @ 400 Hz

Resolution

0.1 V

Line & Load Regulation High V Range

± 0.5 %FS

Line & Load Regulation Low V Range

± 1 %FS

Load Regulation 10 % Line Change

± 0.1 %FS

T.H.D

0.5 typical % @ 50/60 Hz

Output Noise

< 0.1 V typical

Output Frequency

Range

16 – 500Hz

Accuracy

± 0.02%

Resolution below 100 Hz

0.1Hz

Resolution above 100 Hz

1 Hz

Output Current

Steady State Current High V Range

3.0 A rms

Steady State Current Low  V Range

 6.0 A rms

Peak Current High V Range

13.8 A peak

Peak Current Low V Range

27.6 A peak

Protection

Current Limit Mode

Programmable trip level: Output trips off

(Output shut off) Resolution

0.1 A rms

Over Temperature

Output shut off

Over Voltage

Output shut off

Input

Line Voltage 2 wire + GND

100-240 V rms Maximum operating range 85 – 265 V rms

Line Current (fused)

< 15 A rms

Line Frequency

47 – 63 Hz

Holdup Time

20 ms

Power Factor

> 0.95 typical

Isolation Input/output to Chassis

1350 V / 2200 V