E&I 1040L RF Power Amplifier 10 kHz – 5 MHz 400W is a rugged source of RF power for ultrasonic, induction heating and laser modulation as well as plasma applications. It is a totally solid-state solution employing RF DMoS FETs in the power amplification stages, offering simultaneous forward and reverse power readouts, and RS232 port for data collection. The 1040L reflects E&I’s commitment to reliable and robust RF power.

Flexible Operation:

The 1040L produces 400 Watts of quasi linear class AB power over a frequency range of 10 KHz to 5 MHz, with a nominal power gain of 55 dB (±2dB). Operation over the entire frequency range is possible without the need for any switching.

The front panel display provides simultaneous measurements of forward and reflected power as well as the unit’s status. The RS232 connector at the rear of the unit can also be used to capture this data and reset the unit should a fault occur.

The E&I 1040L is a 19” rack mount unit 3U high. It employs an integral power supply capable of operation at 115 or 220 VAC, 50 – 60 Hz.

Features

  • 400 Watts RF Power
  • 10 KHz – 5 MHz
  • Class AB Performance
  • VSWR Power Measurements
  • Power Measurement – Forward & Reflected
  • Forced Air Cooling
  • Solid State Reliability
Download Data Sheet
Print
Email

Specifications

Primary Performance Characteristics
Start Frequency 10 kHz
Stop Frequency 5 MHz
Rated Power (P1dB) 400 W
Saturated Power Output 500 W
Power Gain 55 dB nominal
Gain Flatness ±1.5 dB to 1 MHz

±2.0 dB to 5 MHz

Input Power for Rated Output 1 mW or 1.14 dBm
Input Impedance / VSWR 50 Ω / VSWR 1.5:1 Max
Output Impedance / VSWR 50 Ω / VSWR 2:1 Max
Harmonic Level Not Specified
Source requirements Any signal / function generator or oscillator capable of 0.7 Vpp into 50 Ω
Ruggedness Any load VSWR, any phase from Open to Short circuit without damage.
Class of Operation Class A
Specifications
AC Input 104 to 240 VAC, 47 to 63 Hz

Current at rated power

9A at 120V

4.5A at 240V

Connectors BNC
Operating Temperature 0 to 45 ºC
Cooling Forced Air Cooling
Front Panel Display Indicates forward and reflected power
Front Panel Accuracy ±3% 100 kHz to 1 MHz
Protection Input: Unit will withstand input signal of +13 dBm without damage.
Mismatch The unit will tolerate any mismatch subject to thermal and current protection
Form Factor
Weight 54 lb. (24.4 kg)
Height 5.3 in 134.5 mm
Width 16.5 in 420.0 mm
Depth 20.0 in 508.0 mm