EM TEST DITO ESD Simulator 16.5 kV

Description

EM TEST DITO ESD Simulator 16.5 kV is designed for the different requirements for testing ESD. Its powerful battery allows to generate more than 50,000 pulses at 16.5kV. Its different menu leads the user through standard tests, helping to evaluate the test points and allow to find susceptibility levels.

Electrostatic discharges either from a human body to any other part or between two different objects can cause persistent disturbances or even destruction to sensitive electronics or controls. Voltages of several 1,000 volts are generated.

DITO simulates ESD pulses as per EN/IEC 61000-4-2 and other standards requirements.

Features

  • Most ergonomic design
  • Light weight (870g)
  • Interchangeable discharge tips
  • Interchangeable R/C networks
  • LiFePO4 power booster to perform long duration tests
  • Library of standard test routines
  • Test voltage measurement and control
  • Various test routines for testing and evaluation
  • High-sophisticated user guidance by test plans created by esd.control software
  • Optional fiber optic link between dito and computer (USB port)
Download Data Sheet
Print
Email

Specifications

CD mode 500V – 10,000V +/-5%
AD mode 500V – 16,500V +/-5%
Resolution 100V steps
Holding time More than 5 seconds
Polarity Positive, negative
Test voltage measured, indicated in the display
Single mode Release of single pulses
Continuous mode Continuous discharge up to

20Hz (AD) and 10Hz (CD)

Pulse release via software Remote control from computer via fiber optic link (USB)
CD mode EN/IEC 61000-4-2; 150pF/330ohm
Rise time 0.8ns +/- 25%
Current 1st peak 7.5A +/- 15% @2kV

15.0A +/- 15% @4kV

22.5A +/- 15% @6kV

30.0A +/- 15% @8kV

Current at 30ns 4.0A +/- 30% @2kV

8.0A +/- 30% @4kV

12.0A +/- 30% @6kV

16.0A +/- 30% @8kV

Current at 60ns 2.0A +/- 30% @2kV

4.0A +/- 30% @4kV

6.0A +/- 30% @6kV

8.0A +/- 30% @8kV

Weight 940 grams incl. battery
Case material ABS; non-inflammable as per UL 94VO
Temperature 5°C – 40°C (operation conditions)
Rel. humiditiy 20% – 80% (operation conditions)
Battery charger 100V – 240V +/-10%; 50/60Hz

Charging time less than 1.5 hours